What are the electrical requirements for a washing machine?

13, May. 2024

 

Washer - Electrical Requirements and Breaker Size

Washer - Electrical Requirements and Breaker Size

Listed below are the typical electrical requirements for washers. For model specific installation details, be sure to take a look at the Installation Instructions that come with your appliance.

If you are looking for more details, kindly visit electric front loader factory.

 

GE and Hotpoint, Top-Load, Front-Load, as well as Portable and Stationary Spacemaker and Space-Saving washers:

  • Requires a 120 Volt, 60 Hertz, individual, properly grounded branch circuit with a 3 prong grounding type receptacle, protected by a 15 or 20 Amp circuit breaker or time-delay fuse.

  • Will not operate if voltage is lower than 102 Volts or higher than 132 Volts.

 

GE Unitized, Spacemaker Washer/Dryer models:

Contact us to discuss your requirements of advantages of 3-wheel dump trucks. Our experienced sales team can help you identify the options that best suit your needs.

  • Washer with electric dryer: Requires a 208/240 Volt, 60 Hertz, individual, properly grounded branch circuit with a 3 prong or 4 prong, grounding type receptacle, protected by a 30 amp circuit breaker or time-delay fuse.

  • Washer with gas dryer: Requires a 120 Volt, 60 hertz, individual, properly grounded branch circuit with a 3 prong grounding type receptacle, protected by a 15 or 20 amp circuit breaker or time-delay fuse.

 

For model specific electrical requirements, please consult the Installation Instructions for the model you own.

Laundry circuit requirements

Code uses the term Laundry Area and Laundry Equipment in 210.52(F) "at least one outlet shall be installed in areas designated for the installation of laundry equipment".
The laundry area could be in a bedroom...

 