What is Ultra High Purity Nitrogen Generator and Why Do We Use Them?

23, Jun. 2025

 

Nitrogen Generators: Everything You Need To Know - Organomation

A laboratory nitrogen generator is a machine that is able to separate nitrogen molecules from the air around it by using a compressed air source. By removing the vast majority of oxygen molecules and other impurities from an air source, these machines are able to produce high purity or ultra-high purity nitrogen gas needed to run a variety of different laboratory applications and instruments.

Benyuan supply professional and honest service.

There are many applications that require a lab to use a nitrogen gas generator, with LC-MS, GC, ICP, ELSD, and sample preparation/blowdown evaporation being the most common. Each application will have specific nitrogen requirements (flow rate, purity level, etc.) which will determine the exact type of N2 generator needed by the lab.

N2 gas generators aren’t the only way labs are able to obtain nitrogen. Let’s get into some other common sources, and discuss when they may be a better fit.
 

Although nitrogen generators are a must-have for many laboratories, there are some instances where they just don’t make sense. Some labs may have a nitrogen consumption rate that is just too high for a generator to meet. On the other hand, some may require such a low amount of gas that the purchase of a generator can’t be justified.

So what are the common nitrogen gas sources for labs and who should be using each?

Ordering nitrogen gas from a third party vendor and having it delivered to your facility in tanks, cylinders, or Dewars is a great option for labs who have a very low or sporadic need for nitrogen. It’s a convenient way to get a small amount of N2 gas which may only be needed for a single project, without committing to the purchase of a new piece of equipment.

The technology behind membrane-based nitrogen generators is…you guessed it…a membrane. This type of generator contains a series of narrow, semi-permeable fibers located in a porous membrane. As compressed air is passed through, some gas molecules such as oxygen, carbon dioxide and water vapor are able to permeate the fibers quite easily and are vented off, while nitrogen molecules pass through much slower. This results in a high purity nitrogen stream (95-99% purity) from the membrane outlet.

Continue reading here for a more in-depth explanation on how membrane nitrogen generators work.

Organomation’s NITRO-GEN is a popular membrane-based N2 generator for sample preparation that is used by analytical laboratories worldwide. Producing up to 20 L/min at up to 99% purity, this lightweight generator is suitable for those using blowdown evaporation for solvent concentration. Find out how the NITRO-GEN supplies high purity nitrogen for a sample concentrator.

PSA generators work by using two columns of tightly packed material called Carbon Molecular Sieve (CMS). Compressed air will pass through one CMS column, which will adsorb all oxygen, water vapor and other molecules, while allowing nitrogen to pass through and be stored in an accumulation tank. Once one sieve becomes saturated, compressed air will be diverted to the second CMS column, allowing the first one to depressurize, releasing all adsorbed impurities through an outlet. This process repeats over and over, leaving behind N2 gas with a 98-99.999% purity.

Continue reading here for a more in-depth explanation on how PSA technology works.

As this technology tends to produce a slightly higher purity and flow rate than with membranes, PSA generators are a great choice for both sample preparation and LC-MS applications. The NITRO-GEN+ is an affordable PSA generation solution that is able to produce up to 35 L/min, meeting all your sample prep and analytical needs. Find out how the NITRO-GEN+ can be your laboratory’s all-in-one nitrogen generation solution.

For more information on the pros and cons of each generator type, go to "which generator technology is right for me?"

Although seen as the popular and “traditional” nitrogen generation solution by many, the process of purchasing N2 tanks is quite pricey, especially for those consuming gas on a weekly or daily basis. There are many associated costs with tank-based solutions including the cost of the actual nitrogen, tank rentals, and required delivery. Let’s take a look at how much one analytical lab could be spending on tanks in just one year.

** This example uses estimated pricing. Your actual costs may vary.

A typical nitrogen tank costs around $50. It’s also common for vendors to charge a monthly rental fee, which is often around $20 each month, per individual cylinder. On top of that, you’ll be charged for delivery – for this example, let’s say the lab orders their tanks locally and it only costs them $25 per delivery.

Now, let’s estimate the nitrogen consumption for this particular lab. Let’s say they need 30 L/min of nitrogen for 4 hours a day, 5 days a week. That equals 36,000 liters of nitrogen per week, or about 5 cylinders. Over the course of a whole year, that’s nearing 2 million liters and over 250 nitrogen cylinders.

In just one year, this lab would be spending over $18,000 in nitrogen tanks alone! For most, this just isn’t feasible.

Acquiring a generator and producing your own nitrogen is a sure way to cut back on these extensive costs. Laboratory generators that are able to produce moderate flow rates and purity levels can range anywhere from $5,000 to $40,000. This one-time payment plus any required maintenance are the only things you have to take care of. No more worrying about rental costs, delivery costs, or wondering why the price of tanks has suddenly increased.

Depending on a lab’s nitrogen consumption levels, the payback period on a N2 generator could be as little as 1-3 years.

Determine how long it would take your lab to pay off a generator by using this simple nitrogen generator payback period calculator, and see how much you could be saving.

If you want to learn more, please visit our website Ultra High Purity Nitrogen Generator.

Let’s say you’re in the middle of concentrating down some analytical samples using a nitrogen dryer, and your nitrogen tank has just run out. You’re forced to stop the evaporation process, disconnect the empty tank, move it aside, bring in a new tank, recalibrate it, and hook it up to the evaporator. All the while your samples are sitting in the open air with the risk of oxidizing or otherwise becoming contaminated. With the constant gas supply a N2 generator provides, you’ll never have to worry about this happening.

Nitrogen Gas Generation: Understanding Purity vs. Flow - PneuTech

Nitrogen gas generation involves a crucial balance between purity and flow rate, with each parameter significantly impacting the other. High purity levels are essential for certain applications but require careful management of the flow rate to achieve. Conversely, prioritizing flow rate can lead to compromises in gas purity, affecting its suitability for specific uses. This blog explores how to navigate the balance between purity and flow to optimize nitrogen gas generation for various industrial needs.

The Relationship Between Purity and Flow in Nitrogen Generation

Pressure and flow are both important concepts for nitrogen generation.

When determining your nitrogen needs and sizing a nitrogen generation system, you need to first understand:

  • What is the volume of nitrogen that you need to produce?
  • How pure does that nitrogen need to be?

Achieving higher purity will require either a larger nitrogen generation system, more time for separation (via membrane or adsorption), or both. The same nitrogen generator can either produce higher volumes of gas at lower purities or lower volumes of gas at higher purities.

Nitrogen Flow Rate

The flow rate in nitrogen generation refers to the volume of nitrogen gas produced or delivered by the generation system per unit of time. It’s typically measured in cubic feet per minute (CFM) or cubic feet per hour (CFH). The flow rate indicates the system’s capacity to supply nitrogen gas to meet the demands of specific applications or processes that require nitrogen.

Nitrogen Purity

In the context of gas generation, nitrogen purity refers to the concentration of nitrogen in the produced gas, indicating how much of the gas is pure nitrogen compared to other gasses present. It is usually expressed as a percentage, with higher percentages indicating a greater concentration of nitrogen.

Nitrogen makes up about 78% of the Earth’s atmosphere by volume. Membrane and PSA nitrogen generators work by separating the nitrogen from oxygen, carbon dioxide, and other trace gasses and impurities in atmospheric air. Depending on the process and the system parameters, onsite nitrogen generators can achieve purity rates between 95% and 99.999% or even higher.

Balancing Flow vs. Purity in Nitrogen Generation

The relationship between flow rate and purity in nitrogen gas generation is inherently a tradeoff due to the limitations of the separation technologies used and the physics of gas separation.

That’s why nitrogen generators are rated for different flow rates at different purity levels; this is commonly provided in spec sheets in the form of a chart. As the purity requirements increase, the flow rate will decrease for both Pressure-Swing Adsorption (PSA) and membrane systems.

Here’s how to understand the tradeoff between flow and purity:

  • Time for separation: Higher purity levels require the separation process, whether through PSA or membrane systems, to be more thorough in removing impurities. This often means slowing down the process to allow more time for the nitrogen to be separated from other gasses, which in turn reduces the volume of nitrogen that can be produced in a given period.
  • Selective permeability and adsorption: In membrane systems, for example, increasing purity means selectively allowing nitrogen to pass through while other gasses are retained or vice versa. Achieving higher purity levels requires the system to be more selective, which naturally limits the flow rate of the nitrogen being produced. Similarly, PSA systems rely on adsorbent materials to bind impurities; higher purities necessitate more adsorbent material, reducing the overall flow rate.
  • Energy consumption: Higher purity levels typically demand more energy per unit of nitrogen produced, as the separation processes become more intensive. This increased energy requirement can lead to higher overall operational costs for high-purity or ultra-high-purity nitrogen generation.

About Nitrogen Purity

Nitrogen purity requirements directly impact the size and overall cost of the nitrogen generation system. Achieving higher purity for a specific flow rate will require a larger, and more expensive, nitrogen generation system. Operating the system at higher purities than required for the application will drive up system costs without any additional benefits. On the other hand, for some applications, it is vitally important to maintain specific purity levels.

Purity Requirements and Applications

Purity levels can vary widely depending on the application requirements, ranging from lower purities (95% to 99.5%) for general industrial use to ultra-high purities (99.999% and above) for specialized applications like electronics manufacturing. Selecting the right nitrogen purity is crucial for ensuring the success and efficiency of the process or application. It requires a careful assessment of the specific needs, costs, and industry standards relevant to the application.

  • 95-97% purity: General industrial applications where nitrogen is used as an inert atmosphere to prevent oxidation or as a blanket gas. Examples include tire inflation, fire suppression systems, and certain chemical processes where high purity is not critical.
  • 98-99% purity: Applications requiring a cleaner inert atmosphere but not ultra-high purity. This range is suitable for food packaging, fermentation processes, and some metal processing applications like annealing, where oxygen levels need to be low but not negligible.
  • 99.9% purity: High-purity applications where even trace amounts of impurities can affect the process or product quality. Examples include pharmaceutical or chemical manufacturing where moisture and oxygen can interfere with product quality and process efficiency.
  • 99.99% purity: Ultra-high purity applications that demand minimal contamination. This level is often required in semiconductor manufacturing, laboratory research, and calibration gasses, where the presence of impurities can significantly impact the processes or results.
  • 99.999% purity: Specialty applications requiring the highest levels of purity, such as in certain analytical instrumentation, electronic chip manufacturing, and processes involving highly sensitive optical and laser equipment. At this purity, even the slightest contamination can have critical consequences.

How to Determine Nitrogen Purity Requirements

Determining the appropriate nitrogen purity requirement for a specific application involves understanding the process’s sensitivity to contaminants, regulatory standards, safety requirements, and the cost implications of producing higher-purity nitrogen.

  • Assess process sensitivity: Evaluate how sensitive the application or process is to oxygen, moisture, and other impurities. Higher sensitivity usually necessitates higher nitrogen purity.
  • Review industry and safety standards: Some industries have specific standards dictating the minimum required purity to ensure product quality, safety, and regulatory compliance.
  • Consider cost implications: Higher purity levels can significantly increase operational costs due to more energy-intensive production and advanced purification technologies. Balance the cost against the benefits of higher purity.
  • Consult with equipment manufacturers: Equipment manufacturers and industry experts can provide recommendations based on extensive experience with similar applications.

Choosing a Nitrogen Generator Based on Purity and Flow

Selecting the right nitrogen generator requires a detailed understanding of your application’s specific needs for nitrogen purity and flow rate. These two factors greatly influence the efficiency, cost-effectiveness, and overall performance of your nitrogen supply system.

Here’s how to approach the selection process with these critical considerations in mind.

1. Assess Your Purity Requirements

First, identify the nitrogen purity level your application requires. Different processes demand varying degrees of purity, impacting the choice of nitrogen generator. Understanding the sensitivity of your process to oxygen and other impurities will guide you in choosing a system that can consistently meet these requirements.

2. Determine Your Flow Rate Needs

The volume of nitrogen your operations consume is just as critical. Measure your peak nitrogen usage in cubic feet per minute (CFM) or cubic feet per hour (CFH) to determine the flow rate you need.

Remember, achieving higher purity levels for a given flow rate will require a larger overall system. Check the spec sheets for the nitrogen generator to determine its max flow rate at the purity levels required.

3. Consider the Type of Nitrogen Generator

With your purity and flow rate requirements in hand, you can now consider the type of nitrogen generator that best suits your needs.

  • Pressure swing adsorption (PSA) systems: Ideal for a wide range of purity levels, from 95% to 99.999%. PSA systems can be designed to meet various flow rate requirements and are ideal for high purity/high flow applications.
  • Membrane nitrogen generators: Best suited for applications requiring nitrogen purity levels between 95% and 99.5%, though higher levels can be achieved in some cases. These systems are valued for their simplicity and lower operating costs but are best for lower purity and/or flow applications.

4. Evaluate Cost vs. Benefit

Higher purity and flow rates can increase the cost of nitrogen generation. It’s essential to evaluate the return on investment (ROI) of meeting your specified purity and flow rates. Consider both the initial capital expenditure and the ongoing operating costs, including energy consumption and maintenance.

5. Future-Proof Your Choice

Consider future expansion or changes in your process that may affect your nitrogen requirements. Opting for a system that offers some flexibility in adjusting purity and flow rates can save significant costs and downtime in the long run.