Beyond the size and cooling capacity that suits the hydroponic system, the hydroponic chiller needs to keep the water at a comfortable temperature. It needs to be cooling fast and on the best budget, yet energy-saving and cushy. You may also want your hydroponic water chiller to be environmentally friendly. These aspects of your chiller’s personality are all affected by how the water chiller is made: how performance it is, what is made of the material?

Use this guide to help you find the best water chiller for a hydroponic you can be blissfully happy with — one that suits your hydro system, economical, long-life, values, and budget. No matter what hydroponic chiller you get, Now based on this guide you will find the best hydroponic water chiller for you!

1. Horsepower

Why it’s important: The horsepower of your hydroponic chiller has a lot to do with how cooling capacity it is — too large, it will waste electricity. Too small, The frequent start and stop of the hydroponic water chiller and the variational load would exacerbate the ullage of the chiller’s life.

The size of the water chiller that you need depends on the size of your hydroponic reservoir. You need to know the size of your reservoir to find the best chiller for your hydroponic garden. For example.

Here is a recommended list of standard water reservoirs and their corresponding water chiller sizes :

Item No.- LD- 1/10 HP 

  • suitable for use in reservoirs, and hydroponic systems.
  • Rated to chill up to 45-gallon hydroponic systems.
  • Large refrigeration capacity
  • Anti-corrosive pure titanium evaporator for both fresh and saltwater
  • The high rate of flow
  • A user-friendly LCD control system
  • Quiet operation
  • 220V-50HZ/ 110V-60HZ are available.

Item No. – LD-1/4 HP 

  • suitable for use in reservoirs, and hydroponic systems.
  • Rated to chill up to 85-gallon hydroponic systems.
  • Large refrigeration capacity
  • Anti-corrosive pure titanium evaporator for both fresh and saltwater
  • The high rate of flow
  • A user-friendly LCD control system
  • Quiet operation
  • 220V-50HZ/ 110V-60HZ are available.

Item No. – LD- 1/2 HP 

  • suitable for use in reservoirs, and hydroponic systems.
  • Rated to chill up to 135-gallon hydroponic systems.
  • Large refrigeration capacity
  • Anti-corrosive pure titanium evaporator for both fresh and saltwater
  • The high rate of flow
  • A user-friendly LCD control system
  • Quiet operation
  • 220V-50HZ/ 110V-60HZ are available.

Item No. – LD- 1 HP 

  • suitable for use in reservoirs, and hydroponic systems.
  • Rated to chill up to 280-gallon hydroponic systems.
  • Freon-free (uses R134a refrigerant)
  • Large refrigeration capacity
  • Anti-corrosive pure titanium evaporator for both fresh and saltwater
  • The high rate of flow
  • A user-friendly LCD control system
  • Cooling and Heating function
  • 220V-50HZ/ 110V-60HZ are available.

Item No. LD-1 1/2 HP 

  • Suitable for use with reservoirs, and hydroponic systems.
  • Features a commercial-grade titanium heat exchanger for optimum performance and corrosion resistance.
  • A high-quality Brand compressor is extremely efficient and reliable.
  • Heavy-duty galvanized steel housing with a durable powder-coated finish.
  • Digital LCD display allows for easy operation.
  • Auto restart and temperature memory in the event of a power failure.
  • Uses environmentally-friendly refrigerant.

Item No. – LD-2 HP 

  • Suitable for use with reservoirs, and hydroponic systems.
  • Features a commercial-grade titanium heat exchanger for optimum performance and corrosion resistance.
  • A high-quality Brand compressor is extremely efficient and reliable.
  • Heavy-duty galvanized steel housing with a durable powder-coated finish.
  • Digital LCD display allows for easy operation.
  • Auto restart and temperature memory in the event of a power failure.
  • Uses environmentally-friendly refrigerant.

Item No. LD-3 HP 

  • Suitable for use with 800 gallons reservoirs, and hydroponic systems.
  • Features a commercial-grade titanium heat exchanger for optimum performance and corrosion resistance.
  • A high-quality Brand compressor is extremely efficient and reliable.
  • Heavy-duty galvanized steel housing with a durable powder-coated finish.
  • Digital LCD display allows for easy operation.
  • Auto restart and temperature memory in the event of a power failure.
  • Uses environmentally-friendly refrigerant.

Item No. LD-5 HP 

  • Suitable for use with gallons reservoirs, and hydroponic systems.
  • Features a commercial-grade titanium heat exchanger for optimum performance and corrosion resistance.
  • A high-quality Brand compressor is extremely efficient and reliable.
  • Heavy-duty galvanized steel housing with a durable powder-coated finish.
  • Digital LCD display allows for easy operation.
  • Auto restart and temperature memory in the event of a power failure.
  • Uses environmentally-friendly refrigerant.

Please click here to know high power Lando hydroponic chiller.

Basic Buying Guide to Choosing the hydroponic chiller:

Consider how big sizes of the hydroponic reservoir you have, how important the cooling capacity is, and the cooling time required.

If your cooling requirements are on the upper end of what is recommended, choose the next largest chiller to ensure an adequately cooled aquarium and healthy inhabitants. Variables include the lowest temperature that the unit will chill to (some go down to 32 F [0 C]), maximum operating temperature (our home can reach 90–95 F [32–35 C] inside during peak summer days), required flow rates, availability of external temperature probes to control the unit, energy consumption (in HP) and thermal power (in BTUs; 1 HP = 12,000 BTU) and noise. So please make sure to match the correct size of the hydroponic water chiller for your system.

2. Material

Why it’s important: The material hydroponic chiller is made of 4 major parts: compressor, evaporator, condenser, and expansion valve dictates its performance, cooling speed, eco-friendliness, and Energy Consumption (how much it yields electricity ), and how it wears over time.

The advantage of Lando Hydroponic Chiller:

  • Made of the brand compressor
  • 100% copper tube with low vibration and high heat transfer.
  • Digital LCD temperature
  • Pure titanium fit for saltwater and freshwater

Basic buying guidelines:

If you’re new to the hydroponic chiller. avoid the traps when you purchase. If you want to stick with the tried and true hydroponic water chiller, which can be used long-life and get the right value for your money. Make sure to choose a water chiller made of 100% original parts.

3. Performance

Why it’s important: A good performance of hydroponics chiller will help you save money ( such as less maintenance, saving energy, and protecting the environment ).

What is the performance of the Lando Hydroponic Chiller?

The company is the world’s best 50 Gallon Water Chiller supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

  • commercial-grade titanium heat exchanger for optimum performance and corrosion resistance
  • Auto restart and temperature memory in the event of a power failure.
  • The uniquely designed heat exchanger provides a 25% BTU per watt advantage over other chillers
  • Brand Compressor
  • The ozone-friendly cooling agent
  • Led/LCD temperature display control accurately
  • Heavy-duty galvanized steel housing with a durable powder-coated finish

4. ECO-Friendly

Why it’s important: As water chiller makers, we hold dear the tenet of not damaging the environment. One was “sustainable development”, or the question of how we can continue developing without damaging the environment

Options: Earth-friendly water chillers are typically used green Freon R134a/R410 / R407c.

Basic buying guide: If eco-friendliness is important to you, avoid water chiller use without green Freon. Which destroys the environment. You can get a hydroponic chiller from Lando that’s eco-friendly and has a long life that meets your needs for easy setup and operation.

5. Budget

Choosing a water chiller for your hydroponic system is not an easy choice with many options on the market. By spending lots of time researching and talking to manufacturers, the Lando Water Chiller is your best chiller that is powerful, energy-efficient, long-lasting and has a long warranty period.

The Lando water chiller with a perfect budget, Any chillers fit for growers, hydroponic systems, or greenhouse and aquarium.
If you are looking for a less expensive chiller that can produce excellent performance, Lando is the perfect option.

6. Style

Once you’ve narrowed your choices down by horsepower, material, performance, eco-friendliness, and budget, there’s only one factor left: style! So go ahead and pick your favorite design or print. After all, you’ll be seeing a lot of hydroponic water chillers from Lando-chillers.com.

If you cannot find your favorite style, Let us know what you need and we make it happen. That is simple.

Take all you’ve learned, and shop all our hydroponics chillers to find your perfect chiller!

               The Ultimate Guide to Choosing the Hydroponic Water Chiller – Conclusion

Hydroponic Chillers come in all sorts of shapes and sizes, and it’s mainly up to you to figure out which one is going to be right for you. All of our hydroponic chillers in this article are indicated their performance.so it’s mainly a job of figuring out what suits you. If you’re completely unsure, Please contact Lando, Our expert will supply you best suggestions.

As a little side note: the cooling capacity of hydroponic water chillers can be affected by a number of factors, including the environment temperature, heat dissipation effect, how to connect pipe, and pump size, and it’s also why we recommend you chose larger HP to match your hydroponic system. Nevertheless, there should be an option here for everyone regardless of your preferences, so hopefully, this guide to choosing the hydroponic water chiller has been informative for you.

How To Choose an Aquarium Chiller and How It Works

How an Aquarium Chiller Works

Most aquarium chillers use a vapor-compression method to chill your aquarium water. While the science behind this process can be a little complicated, it is a good idea to understand the basic principles and components in order to properly operate and maintain the chiller.

The diagram above represents the basic parts found on common aquarium chillers and we've outlined the functions below in order to help you better understand exactly how your aquarium chiller works.

  1. Aquarium water is pumped into the chiller and enters the heat exchange. Inside the heat exchange, aquarium water flows around a series of cool metal coils filled with refrigerant. This is where heat is transferred from your aquarium water into the refrigerant.
  2. The heated refrigerant is compressed and changes from a liquid into a gas inside the compressor. The pressure created inside the compressor is what moves the refrigerant through the cooling system.
  3. The gaseous refrigerant is sent into the condenser from the compressor via pressure. A fan blows air over the condenser cooling the refrigerant inside and expelling heat into the atmosphere around the chiller. This is why it is important to place your chiller in a well-ventilated area. This process is similar to what happens in the radiator in your car.
  4. As the refrigerant passes through the condenser, it is cooled and transformed back into a liquid.
  5. Refrigerant from the condenser passes through an expansion valve which reduces pressure inside the refrigerant line controlling the rate at which the aquarium water is cooled inside the evaporator or heat exchange.
  6. A temperature controller monitors the temperature of your aquarium water and automatically switches the chiller ON when the temperature rises and turns it OFF when temperatures are within a suitable range. The temperature controller is built into most chillers but sometimes sold separately depending on the brand of the chiller.

Choosing The Right Chiller Using BTU

Choosing an aquarium chiller is not only about how much water your aquarium holds, you should also consider how much of a temperature drop you need to achieve and the air temperature around the chiller.  A chiller that only needs to drop the water by 3-5°F does not require as much power as a chiller working to cool the water by 10-15° F. Additionally, warmer ambient air temperatures (above +/- 75° F) around the chiller itself will reduce the cooling power. If the ambient air is too hot, (above 78°F) the chiller may not be able to cool at all. 

With that in mind, there is a simple calculation or general rule we can use to estimate how much energy will be required to reach the desired temperatures in our tanks using BTU - British Thermal Units.  Most chiller manufacturers will provide a BTU/hr rating for their chillers which is how much heat energy (BTU) the chiller can remove per hour. Keep in mind, this formula doesn't account for additional sources of heat and assumes the chiller is placed somewhere with reasonable air temperatures around 70°F. 

BTU - British Thermal Units: Unit of measure that indicates how much power is required to heat one pound of water by one degree F. One gallon of water weighs roughly 8.3 lbs. 

With this information, we can estimate it will require roughly 8.3 BTU/hr to chill one gallon of aquarium water by 1° F. So if you have a 10-gallon aquarium, that will require a chiller capable of 83 BTU/hr to drop the water by 1° F or 416 BTU/hr for a drop of 5° F.

  1. Always reference the manufacturer's recommended maximum tank size ranges but more importantly find out the BTU/hr rating for the chiller.
  2. Estimate how much of a water temperature drop you need to achieve.*
  3. Multiply your tank size in gallons by 8.3. Then multiply that by the number of degrees you need to drop. 
    • (Water volume x 8.3) x #° temperature drop = Appropriate BTU/hr rating

For example, in a 55-gallon aquarium that needs to drop by 4°F to reach the suitable temperature range of 78°F:

  • 456.5 BTU/hr x 4-degree drop = A chiller rated for at least 1,826 BTU/hr 

To make the math easy and be 100% certain you're getting a strong enough chiller, it is best to round up to 10 BTU/hr per gallon of aquarium water for a 1°F drop and use the same formula to estimate the size of the chiller.  It's always better to slightly oversize your chiller as opposed to undersize because an undersized chiller will operate far less efficiently.

Using the same example, in a 55-gallon aquarium that needs to drop by 4°F to reach the suitable temperature range of 78°F:

  • 550 BTU/hr x 4° drop = a chiller rated for at least BTU/hr 

*Manufacturers usually recommend the MAXIMUM tank size but the reality is, it all depends on exactly how many degrees you need to drop the water temperature and the amount of heat your equipment is adding. In a real-world scenario, most tanks that actually need a chiller won't operate any hotter than 83-84° F with the lighting ON and the pumps running. That means a maximum drop of 6° F to reach the suitable tropical water temperatures of 78°.

Do I Really Need a Chiller?

With modern-day LED lighting and DC-powered water pumps, most aquariums placed in a temperature-controlled household probably won't require a chiller. Keeping ambient air temperatures around the tank somewhere around 70°-72° F year-round tends to be sufficient.

AC-powered pumps, metal halide, and high-output fluorescent lighting transfer heat into the aquarium water and used to be the biggest reason home aquarists found the need to use chillers; all of which are dated technologies in modern aquaria. So thanks to modern aquarium technology using less electricity and operating at cooler temperatures, most tropical reef aquariums won't require the use of a chiller. If they do, the necessary drop in temperature is minimal.  

If you plan to keep cold water animals at water temperatures in the low 70s or 60s, a much stronger chiller would be appropriate. 

Want more information on 3 Ton Water Cooled Chiller? Feel free to contact us.

Quick Tips