Preview Engine Room Steam Generator Questions - SeaSources
A
Large steam drums
are not required in the design of a coil-type auxiliary water-tube boiler
because __________.
steam and water
are separated in the accumulator (flash chamber)
the heat of combustion
is sufficient to remove all moisture from the steam
the volume of
steam is small at low pressures
automatic burner
cycling controls steam volume and quality
A
In a coil-type
forced circulation auxiliary water-tube boiler,__________.
steam demand response
is comparatively rapid
steam is recirculated
through heating coils in the boiler
unevaporated feed
water is discharged through the skim tube
steam demand response
is slow
C
The gage glass
on a coil-type auxiliary boiler is connected to the __________.
heating coil inlet
and outlet
surge chamber
accumulator
water softener
A
Which of the following
statements concerning fire-tube boilers is correct?
Combustion gases
flow through the tubes.
Flames impinge
on the tubes.
Combustion occurs
in the tubes.
Water flows through
the tubes.
D
Bottom blow valves
are installed on auxiliary water-tube boilers to __________.
completely drain
the boiler in an emergency
prevent sludge
from forming in the steam drum
remove floating
impurities from the boiler water surface
remove settled
solids from the water drum
B
Auxiliary boilers
are divided into several classifications, one of which is __________.
water-tube supercritical
circulation
water-tube forced
circulation
fire-tube controlled
circulation
fire-tube express
circulation
B
The rate of heat
transfer in a water-tube auxiliary boiler can be increased by __________.
operating the
boiler at less than normal water level
installing fins
on the firesides of water-tubes
increasing the
amount of excess air to the burners
treating the boiler
water with chemical oxygen scavengers
A
Downcomers installed
on auxiliary package boilers are protected from direct contact with hot
gases by __________.
refractory and
insulation
several rows of
screen tubes
steel baffles
water wall tubes
A
The purpose of
try-cocks used on an auxiliary boiler is to __________.
provide an alternate
means of determining the water level, if the gage glass fails
provide a means
of adding chemical feed to the boiler water
provide a means
for blowing down the gage glass
act as a steam
sentinel valve, if any of the fusible plugs should melt
A
The purpose of
the separating nozzle in the accumulator of a water-tube, coil-type, steam
generator is to separate __________.
dry steam from
the steam and water mixture
condensate from
feed water
superheated steam
from saturated steam
sludge accumulations
from feed water
B
The rate of heat
transfer in a water-tube auxiliary boiler can be increased by __________.
operating the
boiler at less than normal water level
installing fins
on the firesides of water-tubes
increasing the
amount of excess air to the burners
treating the boiler
water with chemical oxygen scavengers
B
The tube sheets
installed in a fire-tube auxiliary boiler are normally connected by __________.
girder stays
fire-tubes and
stay-tubes
external boiler
plating
separate crown
sheets
A
Which of the following
statements concerning fire-tube boilers is correct?
Combustion gases
flow through the tubes.
Flames impinge
on the tubes.
Combustion occurs
in the tubes.
Water flows through
the tubes.
D
The boiler shown
in the illustration would be classed as __________. Illustration MO-
forced circulation,
coil-type
two-pass, scotch
marine
two-pass, water-tube
single-pass, fire-tube,
scotch marine
A
Which of the listed
problems will happen when the water level of a fire-tube type auxiliary
boiler approaches the crown sheet?
The fusible plugs
will melt.
The furnace will
explode.
Excess steam will
be generated.
The furnace will
overheat.
B
Fusible plugs
are installed in fire-tube boilers to __________.
provide a means
of draining the boiler
warn the engineer
of low water level
cool the crown
sheet at high firing rates
open the burners'
electrical firing circuits
D
Constant capacity,
pressure atomizing, fuel burners designed to meet a wide variation in steaming
loads on an auxiliary boiler, are __________.
automatically
supplied with warmer air on demand
automatically
supplied with more fuel on demand
equipped with
standard variable capacity atomizers
cycled on and
off in response to steam demand
C
The primary function
of a flame safeguard system, as used on an automatically fired auxiliary
boiler, is to prevent __________.
accidental dry
firing and overpressure
uncontrolled fires
in the furnace
explosions in
the boiler furnace
overheating of
the pressure parts
A
A photoelectric
cell installed in an automatically fired auxiliary boiler burner management
system __________.
opens the burner
circuit upon sensing a flame failure
detects a flame
failure by monitoring radiant heat from glowing refractory
requires mechanical
linkage to secure the burner fuel supply
must be bypassed
at low firing rates
A
During unsafe
firing conditions in a large automatic auxiliary boiler, various control
actuators are interlocked with the burner circuit to prevent start-up, in
addition to safety shutdown. These controls are referred to as __________.
limit controls
flame safeguard
controls
combustion controls
programming controls
B
Which of the listed
sequence of events occurs when an automatic auxiliary boiler is prepurged?
The damper on
the inlet side of the furnace is moved to the open position for a given
number of seconds and then moved to the closed position.
The damper on
the inlet side of the furnace is moved to the open position for a given
number of seconds and then moved to the low fire position.
The damper is
moved to the closed position for a given number of seconds and then moved
to the low fire position.
The damper in
the uptakes is moved to the wide open position for a given number of seconds
and then moved to the low firing rate position.
D
The pressuretrol
which is installed on an auxiliary boiler senses steam pressure changes
and __________.
controls the flow
of feed water to the boiler
monitors the boiler
high water level
secures the fires
when a fusible plug burns out
automatically
regulates the quantity of oil and air flow to the burner
B
Which of the following
actions takes place in the control circuit of an automatically fired auxiliary
boiler when the desired steam pressure is obtained?
A temperature
sensing device opens the circuit breaker in the burner motor.
The high limit
control secures power to the entire oil firing system.
The stack relay
actuates the low limit control which breaks the ignition circuit.
The stack relay
secures power to the high voltage side of the ignition transformer.
C
Which of the following
statements describes how the fuel oil enters the whirling chambers of the
sprayer plates used in an auxiliary boiler return flow fuel oil system?
Through the outer
barrel tube.
Through the sprayer
plate drilled passages.
Through tangential
slots in the sprayer plate.
Through baffles
in the orifice plate.
C
The solenoid valves
in the fuel oil supply line to an automatically fired auxiliary boiler,
are automatically closed by __________.
a decrease in
feed temperature
high furnace air
pressure
high steam pressure
low steam pressure
B
A variable capacity,
pressure atomizing, fuel oil burner functions to __________.
maintain a constant
fuel temperature
provide a wide
range of combustion
provide a constant
fuel return pressure
maintain smokeless
fuel oil atomization
A
When the steam
pressure drops below a set value on an automatically fired auxiliary boiler,
fitted with rotary cup atomizers, the combustion control system will __________.
increase the fuel
oil control valve opening
increase the rotary
cup speed
decrease the back
pressure regulating valve opening
decrease the supply
steam control valve opening
B
Control of the
fuel oil metering valve in an automatically fired auxiliary boiler is accomplished
by a __________.
pressure magnifying
device in the steam coil outlet
steam pressure
sensing device with linkage to the damper air vanes
metering device
in the air supply line
signal from the
feed water electrode
C
Why should the
main steam stop valve of an auxiliary boiler be eased off its seat and then
gently closed before lighting off?
To examine the
valve stem for scars or nicks.
To check for a
tight bonnet seal.
To ensure that
the valve will not be seized shut when hot.
To check the valve
packing.
C
When preparing
to light off a cold boiler equipped with a return flow fuel oil system,
the recirculating valve directs the flow of oil __________.
directly to the
fuel oil heater inlet for further warm-up
back to the fuel
oil settler for further filtration
back to the suction
side of the service pump
directly to the
deep tanks
B
Which of the automatic
boiler controls listed should be tested prior to lighting off an auxiliary
boiler?
Automatic bottom
blow valve
Low water level
cutoff switch
Voltage output
of the ignition transformer
Insulation resistance
readings in the ignition system high tension leads
A
Large steam drums
are not required in the design of a coil-type auxiliary water-tube boiler
because __________.
steam and water
are separated in the accumulator (flash chamber)
the heat of combustion
is sufficient to remove all moisture from the steam
the volume of
steam is small at low pressures
automatic burner
cycling controls steam volume and quality
C
The gage glass
on a coil-type auxiliary boiler is connected to the __________.
heating coil inlet
and outlet
surge chamber
accumulator
water softener
D
Bottom blow valves
are installed on auxiliary water-tube boilers to __________.
completely drain
the boiler in an emergency
prevent sludge
from forming in the steam drum
remove floating
impurities from the boiler water surface
remove settled
solids from the water drum
B
The rate of heat
transfer in a water-tube auxiliary boiler can be increased by __________.
operating the
boiler at less than normal water level
installing fins
on the firesides of water-tubes
increasing the
amount of excess air to the burners
treating the boiler
water with chemical oxygen scavengers
A
The purpose of
try-cocks used on an auxiliary boiler is to __________.
provide an alternate
means of determining the water level, if the gage glass fails
provide a means
of adding chemical feed to the boiler water
provide a means
for blowing down the gage glass
act as a steam
sentinel valve, if any of the fusible plugs should melt
B
The rate of heat
transfer in a water-tube auxiliary boiler can be increased by __________.
operating the
boiler at less than normal water level
installing fins
on the firesides of water-tubes
increasing the
amount of excess air to the burners
treating the boiler
water with chemical oxygen scavengers
B
The tube sheets
installed in a fire-tube auxiliary boiler are normally connected by __________.
girder stays
fire-tubes and
stay-tubes
external boiler
plating
separate crown
sheets
A
Which of the following
statements concerning fire-tube boilers is correct?
Combustion gases
flow through the tubes.
Flames impinge
on the tubes.
Combustion occurs
in the tubes.
Water flows through
the tubes.
C
The boiler shown
in the illustration would be classed as __________. Illustration MO-
two-pass, water-tube
two-pass, scotch
marine
single-pass, fire-tube,
scotch marine
forced circulation,
coil-type
A
Which of the listed
problems will happen when the water level of a fire-tube type auxiliary
boiler approaches the crown sheet?
The fusible plugs
will melt.
The furnace will
explode.
Excess steam will
be generated.
The furnace will
overheat.
B
Fusible plugs
are installed in fire-tube boilers to __________.
provide a means
of draining the boiler
warn the engineer
of low water level
cool the crown
sheet at high firing rates
open the burners'
electrical firing circuits
D
Constant capacity,
pressure atomizing, fuel burners designed to meet a wide variation in steaming
loads on an auxiliary boiler, are __________.
automatically
supplied with warmer air on demand
automatically
supplied with more fuel on demand
equipped with
standard variable capacity atomizers
cycled on and
off in response to steam demand
C
The primary function
of a flame safeguard system, as used on an automatically fired auxiliary
boiler, is to prevent __________.
accidental dry
firing and overpressure
uncontrolled fires
in the furnace
explosions in
the boiler furnace
overheating of
the pressure parts
A
A photoelectric
cell installed in an automatically fired auxiliary boiler burner management
system __________.
opens the burner
circuit upon sensing a flame failure
detects a flame
failure by monitoring radiant heat from glowing refractory
requires mechanical
linkage to secure the burner fuel supply
must be bypassed
at low firing rates
A
During unsafe
firing conditions in a large automatic auxiliary boiler, various control
actuators are interlocked with the burner circuit to prevent start-up, in
addition to safety shutdown. These controls are referred to as __________.
limit controls
flame safeguard
controls
combustion controls
programming controls
B
Which of the listed
sequence of events occurs when an automatic auxiliary boiler is prepurged?
The damper on
the inlet side of the furnace is moved to the open position for a given
number of seconds and then moved to the closed position.
The damper on
the inlet side of the furnace is moved to the open position for a given
number of seconds and then moved to the low fire position.
The damper is
moved to the closed position for a given number of seconds and then moved
to the low fire position.
The damper in
the uptakes is moved to the wide open position for a given number of seconds
and then moved to the low firing rate position.
D
The pressuretrol
which is installed on an auxiliary boiler senses steam pressure changes
and __________.
controls the flow
of feed water to the boiler
monitors the boiler
high water level
secures the fires
when a fusible plug burns out
automatically
regulates the quantity of oil and air flow to the burner
B
Which of the following
actions takes place in the control circuit of an automatically fired auxiliary
boiler when the desired steam pressure is obtained?
A temperature
sensing device opens the circuit breaker in the burner motor.
The high limit
control secures power to the entire oil firing system.
The stack relay
actuates the low limit control which breaks the ignition circuit.
The stack relay
secures power to the high voltage side of the ignition transformer.
C
Which of the following
statements describes how the fuel oil enters the whirling chambers of the
sprayer plates used in a auxiliary boiler return flow fuel oil system?
Through the outer
barrel tube.
Through the sprayer
plate drilled passages.
Through tangential
slots in the sprayer plate.
Through baffles
in the orifice plate.
C
The solenoid valves
in the fuel oil supply line to an automatically fired auxiliary boiler,
are automatically closed by __________.
a decrease in
feed temperature
high furnace air
pressure
high steam pressure
low steam pressure
B
A variable capacity,
pressure atomizing, fuel oil burner functions to __________.
maintain a constant
fuel temperature
provide a wide
range of combustion
provide a constant
fuel return pressure
maintain smokeless
fuel oil atomization
A
When the steam
pressure drops below a set value on an automatically fired auxiliary boiler,
fitted with rotary cup atomizers, the combustion control system will __________.
increase the fuel
oil control valve opening
increase the rotary
cup speed
decrease the back
pressure regulating valve opening
decrease the supply
steam control valve opening
B
Control of the
fuel oil metering valve in an automatically fired auxiliary boiler is accomplished
by a __________.
pressure magnifying
device in the steam coil outlet
steam pressure
sensing device with linkage to the damper air vanes
metering device
in the air supply line
signal from the
feed water electrode
C
Treatment of boiler
feedwater for the control of hardness is necessary to prevent __________.
excessive feed
water alkalinity
foaming
waterside scale
deposits
carryover
B
A unit of measure
used to express the chloride content of boiler water is __________.
pH
PPM
Micro-Farads
Micro-Ohms
B
Which of the listed
methods can be used to blow down a boiler without securing the fires?
Bottom blow from
the mud drum.
Steam drum surface
blow.
Blow down the
front water wall header.
Blow down the
rear water wall header.
A
Dissolved oxygen
can be removed from the boiler water by __________.
treating the water
with chemical scavengers
dumping and refilling
the boiler weekly
passing the water
through absorbent filters
frequent surface
and bottom blows
A
Eight (ounces
of oxygen, dissolved in 500,000 pounds of water, is a concentration of __________.
1.0 ppm
4.0 ppm
8.0 ppm
16.0 ppm
C
Proper use of
the boiler surface blow will __________.
have no effect
on boiler alkalinity
remove most precipitated
solids
remove floating
impurities from boiler water
disrupt circulation
in a steaming boiler
D
Chemicals are
added to boiler water to __________.
stabilize feed
water if a boiler becomes salted up
eliminate the
need for blow downs
maintain an acidic
condition in the feed water
prevent scale
forming deposits
A
Before giving
a boiler a bottom blow, it should be taken off the line and then the __________.
water level initially
raised above normal
water level initially
lowered below normal
boiler air cock
should be cracked
boiler steam pressure
should be increased
A
As the pH of the
boiler water approaches zero, the water becomes increasingly __________.
acidic
neutral
alkaline
soft
A
Normally a boiler
water sample should be taken __________.
before the boiler
has been blown down or chemicals added
from the highest
point in the feed system
when the boiler
has been refilled with makeup
after the boiler
has been blown down
B
A boiler water
sample being collected for analysis should be circulated through a cooling
coil because __________.
the cool sample
has a higher conductivity measurement and the total dissolved solids in
the water are easier to identify
this keeps the
water from flashing into steam as it is drawn from the higher pressure of
the boiler into atmospheric conditions
it reduces the
amount of suspended matter that frequently finds its way into the dead end
lines
the degree of
acidity as measured on the pH recorder is amplified by cool water temperatures
C
A boiler with
a water capacity of 10 tons, generates steam at the rate of 30 tons per
hour. If the feed water quality is 0.5 ppm, the concentration of solids
will increase 1.5 ppm every hour. What would be the increase in the concentration
of solids within 24 hours?
12 ppm
24 ppm
36 ppm
48 ppm
D
Testing boiler
water for chloride content will indicate the amount of __________.
phosphates present
in the water
total alkalinity
in the water
methyl orange
that should be added
dissolved salts
from sea contamination
D
The amount of
sodium phosphate in treated boiler water can be measured by a/an __________.
alkalinity test
chloride test
sodium phosphorous
test
phosphate test
B
A sample of boiler
water can be chemically tested for alkalinity by initially adding a few
drops of phenolphthalein and then slowly titrating the water sample until
the __________.
sample color changes
from clear to pink
sample color changes
from pink to clear
entire concentration
of chlorides have been neutralized
water sample pH
reaches 10.5
C
What boiler water
chemistry is necessary to ensure the precipitation of hard scale forming
calcium?
Boiler water should
be slightly acidic.
Boiler water hardness
should be high.
Boiler water should
have a reserve of phosphates.
Hydrazine concentrations
should be at the proper level.
C
Phenolphthalein
is used as an indicator to test boiler water for __________.
hardness
chloride content
alkalinity
hydrazine
A
A dissolved oxygen
concentration of 8.0 ppm represents __________.
8 ounces of oxygen
dissolved in 1,000,000 ounces of water
8 lbs of oxygen
dissolved in 1,000,000 tons of water
8 tons of oxygen
dissolved in 1,000,000 pounds of water
80 ounces of oxygen
dissolved in 100,000 ounces of water
A
A water-tube boiler
can be laid up either wet or dry. If it is to be laid up wet, you should
__________.
completely fill
the boiler with deaerated feed water and maintain a slight pressure
drain and refill
the boiler when the pH goes above 6
drain and refill
the boiler each week
completely fill
the boiler with water, then blow down to steaming level
C
The major reason
dissolved gases are removed from boiler feedwater is because they may cause
__________.
condenser vacuum
loss
vapor lock in
the feed pumps
corrosive conditions
in the boiler
a false boiler
water level
D
Ferrous sulfate
tends to go into solution in boiler water when the value of the hydrogen
ion concentration increases. Consequently, the water in a 900 psi boiler
should be __________.
pure with zero
pH value
pure and treated
to a pH value of 4.0 to 4.5
maintained at
a pH value of 7.0
pure and treated
to a pH value of 10.5 to 11.0
C
Calcium minerals
in boiler water are precipitated out of solution by the use of which of
the listed chemicals?
Sodium hydroxide
Caustic soda
Sodium phosphate
Phenolphthalein
C
In the prevention
of moisture carryover from a marine boiler, one important consideration
is to __________.
add foaming agents
to the boiler water
properly treat
the boiler water with hydrazine
control the amount
of boiler water solids
maintain a high
boiler water level
A
Although accurate
tests of boiler water for dissolved oxygen are difficult to obtain on board
ship, you can be fairly certain of proper oxygen removal by __________.
maintaining a
normal level of scavenging agents
maintaining low
boiler water pH
testing frequently
for total dissolved solids
giving the boiler
frequent surface blows
D
An adequate phosphate
reserve should be maintained in boiler water to __________.
remove dissolved
oxygen concentrations
reduce the blow
down frequency
maintain a pH
of 7
prevent hard scale
formation
A
When a boiler
water test indicates a pH value of 6, you should __________.
chemically treat
to raise the pH to normal level
begin a continuous
boiler blow down
check the DC heater
for possible malfunction
chemically treat
to lower the pH to normal level
D
Scale prevention
in boiler water is accomplished by adding treatment chemicals to __________.
cause the water
to be neutral
increase boiler
water acidity
solidify the scale
as powder
precipitate scale
forming salts into sludge
B
To minimize metal
corrosion, boiler water is best kept __________.
fairly acidic
alkaline
slightly acidic
neutral
D
If boiler water
chemicals are decreasing in one boiler and increasing in the other boiler,
while both are steaming at normal rates, a leak probably exists in the __________.
feed water crossover
line
superheater tubes
economizer tubes
internal desuperheater
flange
D
Boiler water hardness
is increased by_______.
zero alkalinity
in the water
improper operation
of the DC heater
dissolved gases
in the water
scale forming
salts in the feed water
A
Carbon dioxide
dissolved in boiler water is dangerous in a modern power boiler because
the gas __________.
forms carbonic
acid which attacks the watersides
combines with
sulfates to cause severe waterside pitting
breaks the magnetic
iron oxide film inside boiler tubes
combines with
oxygen to cause severe waterside scaling
C
A leak in a desuperheater
could be indicated by an __________.
increased boiler
water compound level in the boiler with the affected desuperheater
increased concentration
of dissolved oxygen in boiler water
inability to maintain
proper boiler water pH or phosphate levels
inability to maintain
control of boiler water suspended solids
A
Excessive alkalinity
of boiler water will cause __________.
caustic embrittlement
scale formation
sodium sulfite
reacting with dissolved oxygen
calcium carbonate
precipitation
A
The concentration
of total dissolved solids in the boiler water can increase as a result of
__________.
insufficient blow
down
zero water hardness
frequent surface
blows
dissolved oxygen
deaeration
B
Excessive carbon
dioxide formed by improper chemical treatment in the boiler may cause corrosion
in the __________.
boiler generating
tubes
condensate lines
boiler superheater
tubes
main and auxiliary
steam lines
A
A malfunction
in the DC heater is indicated by __________.
the boiler requiring
excessive amounts of oxygen scavenging chemicals
condensate coming
in contact with steam inside the heater
water and steam
entering the DC heater at different temperatures
air flowing from
the DC heater vent connection pipe
B
A boiler with
a water capacity of 10 tons, generates steam at the rate of 30 tons per
hour. If the feed water quality is 0.5 ppm, the concentration of solids
will increase 1.5 ppm every hour. What would be the increase in the concentration
of solids within 24 hours?
48 ppm
36 ppm
24 ppm
12 ppm
C
Testing boiler
water for chloride content will indicate the amount of __________.
total alkalinity
in the water
methyl orange
that should be added
dissolved salts
from sea contamination
phosphates present
in the water
A
A sample of boiler
water can be chemically tested for alkalinity by initially adding a few
drops of phenolphthalein and then slowly titrating the water sample until
the __________.
sample color changes
from pink to clear
water sample pH
reaches 10.5
entire concentration
of chlorides have been neutralized
sample color changes
from clear to pink
C
Phenolphthalein
is used as an indicator to test boiler water for __________.
chloride content
hardness
alkalinity
hydrazine
C
A dissolved oxygen
concentration of 8.0 ppm represents __________.
8 tons of oxygen
dissolved in 1,000,000 pounds of water
8 lbs of oxygen
dissolved in 1,000,000 tons of water
8 ounces of oxygen
dissolved in 1,000,000 ounces of water
80 ounces of oxygen
dissolved in 100,000 ounces of water
D
Calcium minerals
in boiler water are precipitated out of solution by the use of which of
the listed chemicals?
Phenolphthalein
Caustic soda
Sodium hydroxide
Sodium phosphate
A
Although accurate
tests of boiler water for dissolved oxygen are difficult to obtain on board
ship, you can be fairly certain of proper oxygen removal by __________.
maintaining a
normal level of scavenging agents
maintaining low
boiler water pH
testing frequently
for total dissolved solids
giving the boiler
frequent surface blows
A
When a boiler
water test indicates a pH value of 6, you should __________.
chemically treat
to raise the pH to normal level
check the DC heater
for possible malfunction
begin a continuous
boiler blow down
chemically treat
to lower the pH to normal level
D
To minimize metal
corrosion, boiler water is best kept __________.
slightly acidic
neutral
fairly acidic
alkaline
D
If boiler water
chemicals are decreasing in one boiler and increasing in the other boiler,
while both are steaming at normal rates, a leak probably exists in the __________.
superheater tubes
economizer tubes
feed water crossover
line
internal desuperheater
flange
B
Carbon dioxide
dissolved in boiler water is dangerous in a modern power boiler because
the gas __________.
combines with
oxygen to cause severe waterside scaling
forms carbonic
acid which attacks the watersides
combines with
sulfates to cause severe waterside pitting
breaks the magnetic
iron oxide film inside boiler tubes
A
Excessive alkalinity
of boiler water will cause __________.
caustic embrittlement
sodium sulfite
reacting with dissolved oxygen
calcium carbonate
precipitation
scale formation
C
Excessive carbon
dioxide formed by improper chemical treatment in the boiler may cause corrosion
in the __________.
boiler superheater
tubes
boiler generating
tubes
condensate lines
main and auxiliary
steam lines
C
A malfunction
in the DC heater is indicated by __________.
condensate coming
in contact with steam inside the heater
air flowing from
vent condenser vent
the boiler requiring
excessive amounts of oxygen scavenging chemicals
water and steam
entering the DC heater at different temperatures
A
Air accumulated
in the inter condenser of the air ejector assembly is discharged directly
to the __________.
after condenser
high-pressure
turbine
main condenser
atmosphere
B
Which of the devices
listed is used to keep overheated condensate from flowing to the deaerating
feed tank?
Fresh water cooler
Recirculating
line to the main condenser
Salt water cooler
Recirculating
line to the main feed pump
C
The loop seal
connected to the main condenser returns the drains from the __________.
after condenser
vent condenser
inter condenser
All of the above.
C
Main condensate
recirculating systems are primarily intended to __________.
balance and control
condensate temperatures at full load
prevent excessive
overheating of the condensate pumps
provide adequate
cooling water for the air ejector condensers
vent accumulated
vapors from the condensate pump discharge
D
Which statement
is true concerning two-stage air ejector assemblies?
The first stage
air ejector takes suction on the second stage to increase vacuum.
Steam to the after
condenser is condensed and returned to the main condenser via the loop seal.
Air is removed
from the condensate as it passes through the tubes.
The steam/air
mixture from the main condenser is discharged by the first stage air ejector
to the inter condenser.
B
While vacuum is
being raised on the main unit and the turbine is being warmed, condensate
is recirculated to the main condenser to __________.
cool the main
condenser shell for better vacuum
ensure the condensation
of air ejector steam
maintain a proper
DC heater water level
provide a condenser
vacuum seal
A
The automatic
recirculating valve in the main condensate recirculating line is controlled
by a temperature sensor which is located at the __________.
air ejector condensate
discharge
condensate inlet
to the main air ejectors
main condensate
pump suction
main condensate
pump discharge
C
A salinity indicator
cell is located in the __________.
low-pressure turbine
casing drain
evaporator brine
suction line
main condenser
hotwell
sea water side
of the main condenser
C
Serious tube leaks
in the air ejector condenser assembly will cause __________.
fouled nozzles
faulty steam pressure
loss of vacuum
clogged steam
strainers
D
Why does air entry
into the main condenser reduce the efficiency of the steam cycle?
Steam flow rate
through the main turbine increases
Condensate sub
cooling in the main condenser increases
The air mixes
with the steam and enters the condensate
Low-pressure turbine
exhaust steam enthalpy value increases
B
Which statement
listed represents a vital function of the main condenser?
Cooling of the
exhaust steam from the auxiliary exhaust system before it enters the deaerating
feed tank.
The recovery of
feed water for reuse.
Storage of feed
water for immediate use in the boilers.
Condensing of
the exhaust steam from the main feed turbine pumps.
B
Which of the following
actions should be taken to re-establish a 'blown' air ejector loop seal?
Decrease the steam
pressure to the air ejector nozzles.
Momentarily close
the valve in the loop seal line, and then reopen slowly.
Shut off the steam
to the second stage air ejector momentarily then open it again.
Increase the condensate
flow through the air ejector.
A
When condenser
tube ends are rolled into both tube sheets, the different rates of material
expansion are compensated for by utilizing.
expansion joints
in the condenser shell
metallic packing
pressed around the tube ends
threaded brass
ferrules on the tube ends
belled joints
at both tube ends
A
While underway,
vacuum in the main condenser is primarily caused by the __________.
condensing of
the exhausting steam
after condenser
loop seal
main air ejector
suction drawn
by the condensate pump
B
The leakage of
air into the pump casing by way of the packing gland of a condensate pump,
is prevented by __________.
the vacuum in
the pump suction
a water seal line
to the packing gland
special packing
in the stuffing box
an air seal line
from the compressed air line
D
In a marine condenser
designed with a reheating hot well, the hot well is reheated by __________.
recirculation
of condensate
submerged heating
coils supplied with auxiliary exhaust steam
a branch line
from the air ejector steam supply
steam lanes in
the condenser
C
A main condenser
utilizing a scoop for the circulation of sea water must be constructed as
a __________.
two-pass heat
exchanger
counter flow heat
exchanger
single-pass heat
exchanger
parallel flow
heat exchanger
C
If the main condenser
were operating at a vacuum of 28.5" Hg, a condensate discharge temperature
of 86°F, a sea water inlet temperature of 72°F, and a sea water outlet temperature
of 79°F, what would be the condensate depression? Illustration SG-
0.2 inches Hg
0.7 inches Hg
4 degrees Fahrenheit
7 degrees Fahrenheit
B
The differential
temperature of the main condenser cooling water will be significantly affected
by a change in __________.
condensate pump
pressure
volume of cooling
water flow
boiler feed pump
pressure
sea temperature
C
Air accumulated
in the after condenser of the air ejector unit is discharged directly to
the __________.
main condenser
inter condenser
atmosphere
high-pressure
turbine
D
Under normal conditions,
the rate of heat transfer in a feedwater heater is most greatly affected
by the __________.
speed of the main
feed pump
density of the
feed water
pH of the feed
water
temperature differential
between the steam and feed water
C
Which of the following
statements represents the function of a turbine gland exhaust condenser?
Directs the gland
exhaust from the turbine sealing glands to the air ejector suction.
Recovers condensate
from the gland leakage around the ahead and astern throttle valves.
Assists in preheating
the condensate before it enters the DC heater.
Recovers condensate
formed at the gland seal exhaust leak off.
A
The connections
labeled "A" in the illustration, are used to __________. Illustration
SG-
maintain a vacuum
in the shell of the feed water heater
provide a point
of admission for the steam air heater drains
provide a point
of admission for the L.P. bleed steam
drain condensate
from the feed water heater to the main condenser
A
The unit shown
in the illustration is used as the __________. Illustration SG-
combined low-pressure
feed heater
high-pressure
feed heater
flash evaporator
salt water feed heater
Butterworth feed
heater
B
A slight vacuum
is maintained in the shell of the first stage heater shown in the illustration.
The primary reason for the vacuum is to __________. Illustration SG-
provide a low-pressure
area to guarantee feed water flow to the heater
maintain a positive
flow of steam as supplied by the main engine LP bleed system
avoid the necessity
of having to use the condensate pumps
force the use
of the main condenser as the drain cooler
C
The items labeled "A"
in the illustration are the __________. Illustration SG-
low-pressure steam
supply connections
high-pressure
drain connections
low-pressure vent
connections
low-pressure drain
connections
A
The feed water
heater shown in the illustration is actually comprised of three separately
functioning heat exchangers. These heat exchangers are identified as the
__________. Illustration SG-
first-stage heater,
gland exhaust condenser, and drain cooler
drain cooler,
distillate condenser, and fresh water drain collector
inter condenser,
after condenser, and gland exhaust condenser
first-stage heater,
inter condenser, and after condenser
D
Which of the following
statements is correct concerning the operation of the level or drain regulator
associated with the feed water heater shown in the illustration is correct?
Illustration SG-
The regulator
maintains the flow of steam into the first stage heater of this unit.
The regulator
controls the flow rate of condensate leaving the feed water outlet.
The regulator
controls the volume of condensate leaving the gland exhaust condenser.
The regulator
controls the level of condensate collected in the drain cooler section.
A
The steam separator
as used in conjunction with a steam whistle normally drains to which of
the listed drain systems?
High-pressure
Low-pressure
Contaminated
Main turbine
D
The function of
item "E" shown in the illustration is to __________. Illustration
GS-
allow steam/condensate
or air to be evacuated from the unit as sound is produced
act as a reed
to enable the production of sound
pulse supply steam
or air to chamber "M"
control the admission
of steam into chamber "L" as part of the process to produce sound
D
What type of sensor
is normally used with the automatic recirculating valve in the main condensate
line?
Pressure
Continuity
Preset electric
timing sensor
Thermostatic
A
The atmospheric
drain tank (ADT) normally drains to the__________.
main and/or auxiliary
condenser
distillate tank
main and/or auxiliary
air ejector condenser
reserve feed tanks
A
Which of the water
supplies listed below is typically used as a cooling medium for the gland
exhaust condenser, inter condenser, and after condenser of an air ejector
unit?
Condensate
Sea water
Potable water
Evaporator distillate
B
If a salinity
alarm system indicates 2.5 grains per gallon at the main condensate pump
discharge, your first action should be to __________.
open the main
condensate recirculating valve
chemically test
the condensate for chloride content
increase the hydrazine
dosage in the condensate line
blow down the
boilers and add make up water
C
Which of the listed
conditions will always result in dissolved oxygen being carried over from
the main condenser?
Priming in the
boiler
Dumping auxiliary
exhaust steam to the main condenser
Taking on makeup
feed
Excessive DC heater
temperature
C
Which of the components
listed prevents water from flowing back into the auxiliary exhaust line
if the deaerating feed tank becomes flooded?
Reverse-acting
relief valve
Exhaust piping
Check valve
Pumps
D
The DC heater
functions to __________.
ensure recirculation
in the feed water system
chemically treat
feed water to remove carbonic gas
remove the major
amount of non-condensable gases from the main condenser
store, heat, and
deaerate feed water
A
Cooling water
to the vent condenser in a DC heater is supplied by the __________.
main and/or auxiliary
condensate pump
main feed pump
salt water circulator
feed booster pump
A
In a main propulsion
steam turbine installation, the condensate pump initially discharges to
the __________.
air ejector condenser
distillate tank
first stage heater
deaerating feed
tank
A
The leakage of
air into the pump casing by way of the packing gland of a condensate pump,
is prevented by __________.
a water seal line
to the packing gland
the vacuum in
the pump suction
an air seal line
from the compressed air line
special packing
in the stuffing box
B
Condensate pumps
have distinctly noticeable characteristics and can usually be recognized
by their __________.
open impellers
and power ends
large suction
chambers and impeller eyes
speed-limiting
governors and closed impellers
multiple impellers
and pump shaft positions
D
If a ship is to
be laid up for an indefinite period, the steam side of the main condenser
should be __________.
filled with moist
air
pressurized to
approximately 5 psig with nitrogen, 99.5% pure by volume
left under a vacuum
completely drained
of water
D
Excessively hot
water returning to an atmospheric drain tank indicates __________.
there is a loss
of circulating water
the condensate
recirculating valve is open
a heating coil
has ruptured
a steam trap is
hung open
D
Scale in the air
ejector first-stage nozzle could cause a decrease in the __________.
air ejector steam
supply pressure
low-pressure turbine
exhaust temperature
condensing temperature
in the condenser
condenser vacuum
A
Which of the conditions
listed could prevent a centrifugal condensate pump from developing its rated
capacity?
Closing the water
seal line to the packing gland.
Venting the pump
to the vacuum side of the condenser.
Flooding of the
main condenser hotwell.
Operating the
pump with a positive suction head.
B
While maneuvering
out of port, you answer a stop bell. You notice a lot of steam coming out
of the gland exhaust condenser vent, in addition to the main condenser hot
well level being low. For this condition you should __________.
increase steam
pressure to the air ejectors
manually recirculate
condensate and add some makeup feed
speed up the condensate
pump
decrease gland
sealing steam pressure
D
Salt water contamination
of condensate could occur at which component?
Inter condenser
DC heater
After condenser
Fresh water evaporator
A
Clean, low pressure
steam drains are collected in the __________.
atmospheric drain
tank
main condenser
hotwell
deaerating feed
water heater
contaminated drain
inspection tank
D
From which of
the areas listed are condensate drains normally collected and returned to
the low-pressure drain system?
Steam whistle
separator/trap
Steam systems
operating in excess of 150 psi
Each main feed
pump steam supply line
Main and auxiliary
air ejector after condensers
D
A basic comparison
can be made between a low-pressure evaporator operation and a main condenser
with regards to the removal of non-condensable gases. The vacuum drag line
for the main condenser is specifically connected in which area?
main tube bank
steam lane
hotwell
air cooler section
A
Which of the listed
systems would be a potential source for the high-pressure drain system?
Steam systems
operating in excess of 150 psi
Fuel oil tank
heating coils
Laundry steam
pressing machines
Galley steam tables
B
Excess free oxygen
in the boiler feedwater can be the result of __________.
improper operation
of the gland exhauster
improper operation
of the DC heater
steam leaks through
the turbine glands
vapor lock in
the boiler feed pump
A
If the DC heater
relief valve lifts frequently, the cause can be excessive __________.
auxiliary exhaust
steam pressure
makeup feed introduced
to the system
feed water recirculated
from the feed pump
condensate supplied
to the DC heater
D
Which of the conditions
listed may be indicated by the lifting of the DC heater relief valve?
Low water level
continually maintained in the DC heater.
Excessive deaeration
of the feed water.
Low back pressure
in the auxiliary exhaust line.
A malfunctioning
auxiliary exhaust make-up steam regulating valve.
A
Excessive water
loss from the main feed system can be caused by __________.
an atmospheric
drain tank trap frozen in the closed position
a leak in the
desuperheater internal gasket
a vapor bound
main condensate pump
excessive recirculation
of condensate from the outlet of the air ejector condenser to the main condenser
B
In a closed feed
and water cycle, which of the conditions listed could prevent vacuum from
reaching the desired level?
Steam pressure
to air ejectors maintained at 10 psig above designed supply pressure.
Marine growth
on the cooling water side of the main condenser.
Condensate recirculating
back to the condenser during maneuvering.
Steam leaking
from the turbine glands.
C
The water level
in a steaming boiler has risen to within 2 inches of the top of the top
gage glass. Your immediate action should be to __________.
secure the fires
and open the bottom blow valve
open the surface
blow line
reduce the feed
water flow to the boiler
secure the feed
water flow to the boiler
C
On a steam vessel,
if a centrifugal main feed pump were operating at shutoff head with the
recirculating line closed, which of the following conditions could occur?
Excessive diaphragm
seal wear in the feed water regulator.
Water level in
the DC heater would decrease.
Flashing at the
suction side of the pump.
An increased water
level in the steam drum.
B
Air accumulated
in the inter condenser of the air ejector assembly is discharged directly
to the __________.
main condenser
after condenser
atmosphere
high pressure
turbine
D
Which statement
is true concerning two-stage air ejector assemblies?
Steam to the after
condenser is condensed and returned to the main condenser via the loop seal.
Air is removed
from the condensate as it passes through the tubes.
The first stage
air ejector takes suction on the second stage to increase vacuum.
The steam/air
mixture from the main condenser is discharged by the first stage air ejector
to the inter condenser.
D
Serious tube leaks
in the air ejector condenser assembly will cause __________.
fouled nozzles
clogged steam
strainers
faulty steam pressure
loss of vacuum
D
Why does air entry
into the main condenser reduce the efficiency of the steam cycle?
The air mixes
with the steam and enters the condensate
Condensate sub
cooling in the main condenser increases
Steam flow rate
through the main turbine increases
Low pressure turbine
exhaust steam enthalpy value increases
C
Which of the devices
listed is used to keep overheated condensate from flowing to the deaerating
feed tank?
Recirculating
line to the main feed pump
Freshwater cooler
Recirculating
line to the main condenser
Saltwater cooler
D
Which statement
listed represents a vital function of the main condenser?
Storage of feed
water for immediate use in the boilers.
Cooling of the
exhaust steam from the auxiliary exhaust system before it enters the deaerating
feed tank.
Condensing of
the exhaust steam from the main feed turbine pumps.
The recovery of
feed water for reuse.
A
The leakage of
air into the pump casing by way of the packing gland of a condensate pump,
is prevented by __________.
a water seal line
to the packing gland
an air seal line
from the compressed air line
special packing
in the stuffing box
the vacuum in
the pump suction
B
If the main condenser
were operating at a vacuum of 28.5" Hg, a condensate discharge temperature
of 86°F, a sea water inlet temperature of 72°F, and a sea water outlet temperature
of 79°F, what would be the condensate depression? Illustration SG-
0.2 inches Hg
4 degrees Fahrenheit
7 degrees Fahrenheit
0.7 inches Hg
A
Air accumulated
in the after condenser of the air ejector unit is discharged directly to
the __________.
atmosphere
inter condenser
high pressure
turbine
main condenser
A
One of the basic
rules applying to the operation of a single-pass main condenser is that
the __________.
cooling water
overboard should be about 10￉F higher than the inlet temperature
vacuum must be
maintained at 29.92" of Hg. under all operating conditions
quantity of reheating
steam flow through the condenser must be maintained at maximum under all
operating conditions
condensate temperature
must never be allowed to drop below 104ï¾¹F
A
Maintaining low
pressure in a condensing turbine exhaust trunk __________.
enables better
utilization of available heat energy to perform work
eliminates creep
problems in the exhaust trunk during maneuvering
reduces condensate
depression with low seawater temperature
prevents steam
turbulence in the exhaust trunk due to steam laning
C
The connections
labeled "A" in the illustration, are used to __________. Illustration
SG-
provide a point
of admission for the L.P. bleed steam
drain condensate
from the feed water heater to the main condenser
maintain a vacuum
in the shell of the feed water heater
provide a point
of admission for the steam air heater drains
B
The unit shown
in the illustration is used as the __________. Illustration SG-
Butterworth feed
heater
combined low pressure
feed heater
flash evaporator
salt water feed heater
high pressure
feed heater
C
A slight vacuum
is maintained in the shell of the first stage heater shown in the illustration.
The primary reason for the vacuum is to __________. Illustration SG-
force the use
of the main condenser as the drain cooler
provide a low
pressure area to guarantee feed water flow to the heater
maintain a positive
flow of steam as supplied by the main engine LP bleed system
avoid the necessity
of having to use the condensate pumps
B
The steam separator
as used in conjunction with a steam whistle normally drains to which of
the listed drain systems?
Low pressure
High pressure
Contaminated
Main turbine
D
Which of the following
statements represents the function of a turbine gland exhaust condenser?
Recovers condensate
from the gland leakage around the ahead and astern throttle valves.
Recovers condensate
formed at the gland seal exhaust leak off.
Directs the gland
exhaust from the turbine sealing glands to the air ejector suction.
Assists in preheating
the condensate before it enters the DC heater.
A
What type of sensor
is normally used with the automatic recirculating valve in the main condensate
line?
Thermostatic
Continuity
Preset electric
timing sensor
Pressure
B
High pressure
and low pressure drain systems are part of the __________.
contaminated drain
system
condensate drain
system
auxiliary turbine
bleed system
boiler drain system
A
Which of the components
listed prevents water from flowing back into the auxiliary exhaust line
if the deaerating feed tank becomes flooded?
Check valve
Reverse-acting
relief valve
Pumps
Exhaust piping
B
Cooling water
to the vent condenser in a DC heater is supplied by the __________.
salt water circulator
main and/or auxiliary
condensate pump
feed booster pump
main feed pump
B
In a main propulsion
steam turbine installation, the condensate pump initially discharges to
the __________.
deaerating feed
tank
air ejector condenser
first stage heater
distillate tank
D
The leakage of
air into the pump casing by way of the packing gland of a condensate pump,
is prevented by __________.
the vacuum in
the pump suction
special packing
in the stuffing box
an air seal line
from the compressed air line
a water seal line
to the packing gland
B
Condensate pumps
have distinctly noticeable characteristics and can usually be recognized
by their __________.
speed-limiting
governors and closed impellers
large suction
chambers and impeller eyes
open impellers
and power ends
multiple impellers
and pump shaft positions
C
If a ship is to
be laid up for an indefinite period, the steam side of the main condenser
should be __________.
left under a vacuum
filled with moist
air
completely drained
of water
pressurized to
approximately 5 psig with nitrogen, 99.5% pure by volume
B
Vapor blowing
from the air ejector condenser vent may be caused by __________.
low condensate
temperature
insufficient condensate
flow
excessive condensate
pump speed
excess makeup
feed being taken into the system
B
While maneuvering
out of port, you answer a stop bell. You notice a lot of steam coming out
of the gland exhaust condenser vent, in addition to the main condenser hot
well level being low. For this condition you should __________.
speed up the condensate
pump
manually recirculate
condensate and add some makeup feed
decrease gland
sealing steam pressure
increase steam
pressure to the air ejectors
D
Scale in the air
ejector first-stage nozzle could cause a decrease in the __________.
condensing temperature
in the condenser
low pressure turbine
exhaust temperature
air ejector steam
supply pressure
condenser vacuum
B
If the cooling
water flow through the air ejector intercondensers and aftercondensers is
inadequate, which of the problems listed will occur?
Air ejector nozzles
will erode.
Main condenser
absolute pressure will increase.
DC heater level
will rise
After condenser
will be flooded.
C
Excessively hot
water returning to an atmospheric drain tank indicates __________.
there is a loss
of circulating water
a heating coil
has ruptured
a steam trap is
hung open
the condensate
recirculating valve is open
B
Dissolved oxygen
in the condensate can result from __________.
steam leaks into
the gland leak off
air leaks through
the turbine glands
improper operation
of the gland exhauster
vapor lock in
the condensate pump
D
Salt water contamination
of condensate could occur at which component?
Inter condenser
DC heater
After condenser
Fresh water evaporator
A
If the salinity
indicator periodically registers high salinity in the main hot well, the
cause may be __________.
a contaminated
distilled water tank
leaking air ejector
condenser tubes
excessive water
pressure in the lube oil cooler
leaking tubes
in the third-stage heater
A
Which of the conditions
listed could prevent a centrifugal condensate pump from developing its rated
capacity?
Closing the water
seal line to the packing gland.
Operating the
pump with a positive suction head.
Venting the pump
to the vacuum side of the condenser.
Flooding of the
main condenser hot well.
B
Excessive condensate
depression can result in __________.
high condensate
discharge temperature
decreased plant
operating efficiency
insufficient condensate
sub cooling
overheated air
injectors
D
Which of the following
is the advantage of operating a typical closed feedwater system for a marine
boiler when compared to an open feedwater system?
Reduced requirement
for condensate purity.
Allows for lower
feed pump operating pressures.
Reduced steam
requirement for feed water heating.
Increased capability
of removing and controlling dissolved oxygen.
B
Deaeration of
condensate primarily occurs in what section of the illustration shown? Illustration
SG-
main condenser
hotwell
DFT
distilled water
tank
first stage feed
heater
A
Which of the listed
components would be considered the dividing line separating the condensate
system from the feed water system?
Deaerating feed
tank
Main air ejectors
Boiler drum
Main condenser
D
The boiler feedwater
control valve varies the unity relationship between steam and water flow
during periods of __________.
steady boiler
load
minimum boiler
load
overload operation
load change
C
The net positive
suction head of a boiler centrifugal feed pump should be calculated over
and above the __________.
speed of the impeller
impeller ratio
of the pump
feed water vapor
pressure
pump capacity
in gpm
B
In the boiler
steam and water system, pressure is highest in the __________.
dry pipe
feed line
steam stop
mud drum
B
High-pressure
steam drains are normally discharged to the __________.
atmospheric drain
line
DC heater
reserve feed tank
drain and inspection
tank
D
Which of the listed
conditions aids in directing gland leak off steam from the low- pressure
propulsion turbine to pass through the gland exhaust condenser?
Steam pressure
from the low-pressure turbine.
Compressed air
in the air pilot.
Steam pressure
from the high-pressure turbine.
The use of a gland
exhauster fan.
C
Why is it necessary
to have a relief valve protecting the deaerating feed tank from internal
pressure?
Because the tank
receives large amounts of water.
Because the tank
receives auxiliary exhaust.
Because the tank
receives high-pressure drains.
Because the tank
drains to the main condenser.
A
A high water level
in a deaerating feed heater will cause the automatic dump valve to drain
condensate to the __________.
reserve feed tank
main condenser
auxiliary condenser
atmospheric drain
tank
D
Vent condensers
are usually an integral part of deaerating feed heaters and serve to condense
__________.
the gases liberated
by the deaeration process
only steam vented
from high-pressure steam traps
steam vented from
high-pressure steam glands
the steam vapor
entrained with the non-condensable gases
C
To provide emergency
feedwater supply to a steaming boiler, if it becomes necessary to secure
the DC heater, suction should be taken on the distilled water tank using
the __________.
emergency injector
discharge
feed booster pump
emergency feed
pump
main condensate
pump
D
During cold ship
start-up, you should open the feed water outlet and condensate valves to
a DC heater in order to __________.
expel non-condensable
vapors from the vent
prevent excessive
pressure
thoroughly atomize
incoming condensate
avoid running
the feed pump 'dry'
B
The purpose of
the steam control valves installed in the auxiliary exhaust line is to __________.
preheat the condensate
before it enters the vent condenser
control steam
admission and maintain the proper steam spray pattern in the DC heater
regulate back
pressure in the desuperheater line
seal the vent
condenser to prevent the escape of condensate
D
With the steam
control valve wide open during normal operation, the rate of steam flow
from the auxiliary exhaust steam line to the DC heater is actually a function
of __________.
rate of evaporation
in the DC heater
water level in
the DC heater reservoir
spring pressure
of the spray valves
rate of condensation
in the DC heater
A
The gland exhaust
fan draws steam and non-condensable vapors from the gland exhaust condenser
and discharges to the __________.
atmosphere
main condenser
vent condenser
atmospheric drain
tank
A
To prevent pulsations
from developing in the boiler feedwater lines, the discharge side of a reciprocating
feed pump is equipped with a/an __________.
air chamber
relief valve
feed water regulator
reed valve
B
If a centrifugal
main feed pump were operated at shutoff head with the recirculating line
closed, which of the following conditions could occur?
A decreased water
level in the DC heater.
Flashing at the
suction side of the pump.
Excessive diaphragm
seal wear in the feed water regulator.
An increased water
level in the steam drum.
A
The pressure in
the feedwater system must exceed boiler steam drum pressure in order to
__________.
force the feed
water into the boiler
remove the steam
from the steam drum
prevent water
hammer in the lines
prevent air leakage
into the feed water system
D
A turbine-driven
centrifugal feed pump used for boiler feed service should normally be stopped
by __________.
closing off the
steam via the excess pressure pump governor
opening wide the
recirculating valve and then manually closing the throttle
slowly closing
the manual throttle
hand activating
the over speed trip
D
During initial
starting of the standby turbine-driven boiler feed pump, which of the listed
valves should remain closed?
Pump suction valve
Turbine steam
supply valve
Turbine exhaust
valve
Pump discharge
check valve
D
Recirculation
of the feed water ensures a flow of water through the __________.
third stage heater
standby feed pump
suction line
economizer
main feed pump
D
If it is necessary
to operate a turbine driven main feed pump at shut off head, or at less
than 20% of its rated capacity, what will prevent the pump from overheating?
A bypass or recirculating
line led back to the pump impeller eye or suction.
Throttling of
the steam supply valve.
Throttling of
the liquid discharge valve.
A bypass or recirculating
line led back to the source of suction supply.
D
Which of the following
statements is correct regarding the start-up operation of a non-condensing
turbine-driven feed pump?
Secure all drains
prior to admitting any steam to avoid damage to traps.
Keep the steam
exhaust valve closed until steam is applied to ensure that the auxiliary
exhaust line pressure does not drop.
Keep the pump
casing vent valve closed until flow is established through the pump.
Open the pump
suction valve prior to admitting steam to the turbine.
B
The main boiler
feed pump discharge is controlled by the admission of steam to the auxiliary
turbine. The admission of steam is normally regulated by a __________.
flyweight controlled
regulating valve
constant pump
discharge pressure governor
multi nozzle arrangement
constant speed
limiting governor
A
Under EMERGENCY
operating conditions, the proper valve positions for controlling feedwater
to the boiler should be the __________.
auxiliary stop
valve fully open and the auxiliary stop-check valve used to regulate the
amount of flow
auxiliary stop-check
valve fully open and the auxiliary stop valve used to regulate the amount
of flow
auxiliary stop
and stop-check valves fully open and the feed pump speed used to regulate
the amount of flow
auxiliary stop-check
valve fully open and the auxiliary stop valve regulated by the feed water
regulator
C
In the system
illustrated the valves at point "A" are __________. Illustration
SG-
swing check/stop
valves
globe valves/gate
valves
stop-check/stop
valves
gauge valves/drain
valves
B
When operating
with the auxiliary feed line, feedwater flow is controlled __________.
automatically
by the main feed water regulator
manually by throttling
the auxiliary feed stop-check valve
manually by adjustment
of the auxiliary feed water regulator spring setting
automatically
by the economizer bypass
B
The main feed
check valve functions to __________.
reduce feed pump
discharge pressure loading
prevent backflow
of water from the boiler in the event of a feed pump failure
check pressure
pulsations in the feed line
provide feed pump
positive discharge head
C
A boiler feed
stop valve must be mounted __________.
between the feed
pump and the feed check valve
at or near the
engine room operating platform
between the feed
check valve and the boiler drum
upstream of the
feed water regulator
D
Which piping system
is described in the illustration provided? Illustration SG-
Auxiliary desuperheated
steam system
Main superheated
steam system
Turbine bleed
steam system
Boiler feed and
condensate system
D
If manual control
of the water level in a steaming boiler is required, the proper method of
control is with the auxiliary feed __________.
stop valve
pump pressure
control
pump speed control
stop-check valve
A
The boiler main
feed stop check valve is located nearest the __________.
main feed water
regulator inlet
DC heater feed
water outlet
boiler water drum
inlet
first stage feed
water heater outlet
C
A triple element,
main propulsion, boiler feedwater regulating system commonly used aboard
ship utilizes __________.
two-position differential
gap action
proportional action
proportional plus
reset plus rate action
proportional plus
reset action
C
A two-element
boiler feedwater regulator is controlled by __________.
steam flow and
feed water flow
drum water level
and drum pressure
steam flow and
drum water level
drum water level
and feed water flow
C
The two-element
feedwater regulator functions similarly to the three-element feedwater regulator,
but does not utilize __________.
water level
steam flow measurement
feed water flow
measurement
drum pressure
C
A pneumatic dual
element, main propulsion, boiler feedwater regulating system commonly used
aboard ship utilizes __________.
two-position differential
action
on off reset action
proportional plus
reset action
proportional action
A
A single element
boiler feed water regulating system used aboard ship utilizes
proportional action
proportional plus
reset action
proportional plus
reset plus rate action
two-position differential
gap action
B
A major difference
between the two element and the three element feed water regulator control
systems is that a three element system will additionally measure and incorporate
the __________.
steam flow to
the feed water regulator
feed water flow
as sensed variable
drum water level
to the feed water regulator
fuel oil flow
to the feed water regulator
B
Which type of
feedwater regulator listed provides the MOST effective regulation of boiler
water level under all operating conditions?
Single-element
Triple-element
Monothermonic
Double-element
D
When operating
with the auxiliary feed line, feedwater flow is controlled __________.
automatically
by the main feed water regulator
automatically
by the economizer bypass
manually by adjustment
of the auxiliary feed water regulator spring setting
manually by throttling
the auxiliary feed stop-check valve
D
While underway
on watch in the engine room of a steam vessel, the proper valve positions
for controlling feed water to the boiler using the auxiliary feed system
should be
the stop and check
valves fully open and the feed pump speed used to regulate the amount of
flow
the check valve
fully open and the stop valve regulated by the feed water regulator
the auxiliary
check valve fully open and the stop valve used to regulate the amount of
flow
the stop valve
fully open and the auxiliary check valve used to regulate the amount of
flow
C
Which system should
be tested and used when required to raise the water level in an idle boiler?
Superheated steam
system
Desuperheated
steam system
Auxiliary feed
system
Chemical feed
system
D
If the DC heater
relief valve lifts frequently, the cause can be excessive __________.
condensate supplied
to the DC heater
feed water recirculated
from the feed pump
makeup feed introduced
to the system
auxiliary exhaust
steam pressure
D
Which of the conditions
listed may be indicated by the lifting of the DC heater relief valve?
Excessive deaeration
of the feed water.
Low back pressure
in the auxiliary exhaust line.
Low water level
continually maintained in the DC heater.
A malfunctioning
auxiliary exhaust make-up steam regulating valve.
D
In a closed feed
and water cycle, which of the conditions listed could prevent vacuum from
reaching the desired level?
Condensate recirculating
back to the condenser during maneuvering.
Steam pressure
to air ejectors maintained at 10 psig above designed supply pressure.
Steam leaking
from the turbine glands.
Marine growth
on the cooling water side of the main condenser.
B
The water level
in a steaming boiler has risen to within 2 inches from the top of the gage
glass. Your immediate action should be to __________.
secure the fires
and open the bottom blow valve
reduce the feed
water flow to the boiler
open the surface
blow line
secure the feed
water flow to the boiler
D
The feed water
heater shown in the illustration was designed to maintain the required feed
water outlet temperature with an approximate 10" (25.4 cm) Hg shell
vacuum. If the shell vacuum is increased to approximately 16" (40.64
cm) Hg vacuum, the __________. Illustration SG-
flow rate of condensate
to the feed heater will increase
overall plant
operating efficiency will increase
vacuum in the
main condenser will drop as the feed heater shell vacuum increases
feed water outlet
temperature will decrease
B
Which piping system
is described in the illustration provided. Illustration SG-
Auxiliary desuperheated
steam system
Boiler feed and
condensate system
Main superheated
steam system
Turbine bleed
steam system
D
If manual control
of the water level in a steaming boiler is required, the proper method of
control is with the auxiliary feed __________.
pump pressure
control
pump speed control
stop valve
stop-check valve
D
The boiler main
feed stop check valve is located nearest the __________.
DC heater feed
water outlet
boiler water drum
inlet
first stage feed
water heater outlet
main feed water
regulator inlet
A
When operating
with the auxiliary feed line, feedwater flow is controlled __________.
manually by throttling
the auxiliary feed stop-check valve
automatically
by the main feed water regulator
manually by adjustment
of the auxiliary feed water regulator spring setting
automatically
by the economizer bypass
B
A boiler feed
stop-valve must be mounted __________.
at or near the
engine room operating platform
between the feed
check valve and the boiler drum
upstream of the
feed water regulator
between the feed
pump and the feed check valve
C
The pressure in
the feedwater system must exceed boiler steam drum pressure in order to
__________.
prevent air leakage
into the feed water system
prevent water
hammer in the lines
force the feed
water into the boiler
remove the steam
from the steam drum
D
Which of the following
statements is correct regarding the start-up operation of a non-condensing
turbine-driven feed pump?
Secure all drains
prior to admitting any steam to avoid damage to traps.
Keep the steam
exhaust valve closed until steam is applied to ensure that the auxiliary
exhaust line pressure does not drop.
Keep the pump
casing vent valve closed until flow is established through the pump.
Open the pump
suction valve prior to admitting steam to the turbine.
C
Recirculation
of the feed water ensures a flow of water through the __________.
standby feed pump
suction line
third stage heater
main feed pump
economizer
B
During initial
starting of the standby turbine-driven boiler feed pump, which of the listed
valves should remain closed?
Turbine exhaust
valve
Pump discharge
check valve
Turbine steam
supply valve
Pump suction valve
D
A turbine-driven
centrifugal feed pump used for boiler feed service should normally be stopped
by __________.
opening wide the
recirculating valve and then manually closing the throttle
slowly closing
the manual throttle
closing off the
steam via the excess pressure pump governor
hand activating
the over speed trip
A
Why is it necessary
to have a relief valve protect the deaerating feed tank from internal pressure?
Because the tank
receives high pressure drains.
Because the tank
drains to the main condenser.
Because the tank
receives large amounts of water.
Because the tank
receives auxiliary exhaust.
B
To provide emergency
feedwater supply to a steaming boiler, if it becomes necessary to secure
the DC heater, suction should be taken on the distilled water tank using
the __________.
feed booster pump
emergency feed
pump
emergency injector
discharge
main condensate
pump
B
High pressure
steam drains are normally discharged to the __________.
reserve feed tank
DC heater
atmospheric drain
line
drain and inspection
tank
C
The purpose of
the steam control valves installed in the auxiliary exhaust line is to __________.
regulate back
pressure in the desuperheater line
seal the vent
condenser to prevent the escape of condensate
control steam
admission and maintain the proper steam spray pattern in the DC heater
preheat the condensate
before it enters the vent condenser
A
The gland exhaust
fan draws steam and non-condensable vapors from the gland exhaust condenser
and discharges to the __________.
atmosphere
main condenser
vent condenser
atmospheric drain
tank
C
Deaeration of
condensate primarily occurs in what section of the illustration shown. Illustration
SG-
distilled water
tank
main condenser
hot well
DFT
first stage feed
heater
B
Proper lagging
of a single-element feedwater regulator is accomplished by applying the
insulation material __________.
only as necessary
to prevent possible injury
to the steam connection,
but not water connection
to both connections,
including finned areas
to the water connection,
but not steam connection
A
A two-element
boiler feedwater regulator is controlled by __________.
steam flow and
drum water level
drum water level
and drum pressure
drum water level
and feed water flow
steam flow and
feed water flow
D
A pneumatic dual
element, main propulsion, boiler feedwater regulating system commonly used
aboard ship utilizes __________.
two-position differential
action
on off reset action
proportional action
proportional plus
reset action
C
A single element
boiler feed water regulating system used aboard ship utilizes
two position differential
gap action
proportional plus
reset action
proportional action
proportional plus
reset plus rate action
B
The property of
a fuel oil which is a measurement of its available energy, is known as its
__________.
Cetane index
heating value
viscosity index
Cetane number
C
Which combustible
element in fuel oil is considered a significant and major source of air
pollution?
Hydrogen
Vanadium
Sulfur
Nitrogen
D
The BTU value
of fuel oil is determined by a/an __________.
open cup test
hydrometer
viscosimeter
calorimeter
D
The flash point
of a residual fuel oil should be used to determine the highest temperature
to which the oil may be heated __________.
in the recirculating
line
for atomizing
for centrifuging
in a storage tank
D
Which of the significant
combustible elements of fuel oil is a major source of boiler corrosion?
Carbon
Oxygen
Hydrogen
Sulfur
B
The temperature
of the fuel oil received during bunkering operations is critical in determining
the __________.
flash point at
which the fuel will burn
expansion space
to leave in a tank
rate at which
the fuel can be pumped during transfer operations
temperature to
which the fuel must be heated
B
The minimum temperature
requirements for fuel oil in storage tanks is related to the __________.
size of the vents
pump ability of
the oil
fire point of
the oil
size of the containment
area in case of overflow
C
According to Coast
Guard Regulations (46 CFR), what is the minimum flash point of oil to be
used as fuel for the boilers?
80°F (26.7°C)
110°F (43.3°C)
140°F (60.0°C)
150°F (65.6°C)
B
The main reason
for having a low suction line on the fuel oil service or settling tanks
is to __________.
prevent loss of
suction during rough weather
facilitate water
removal
decrease suction
head on the pump
increase the amount
of fuel available for use
B
The most harmful
slag forming compounds found in fuel oils are __________.
potassium and
nickel
vanadium and sodium
calcium and silica
iron and sulfur
A
Which constituent
of fuel oil determines the specific heat?
Hydrocarbons
Oxygen
Nitrogen
Sulfur
C
When heated, fuel
oil will __________.
increase in specific
gravity
increase in viscosity
expand in volume
have a higher
specific heat
C
Using an oil temperature-viscosity
chart, you can determine the recommended __________.
oil pressure for
smokeless operation
fuel/air ratio
for efficient combustion
oil temperature
for proper atomization
fuel oil flash
point for best combustion
A
If the theoretical
quantity of dry air required to burn one pound of fuel oil is 13.75 pounds,
what is the weight of air per pound of fuel when operating a boiler at 5%
excess air?
14.44 pounds
15.13 pounds
15.81 pounds
16.50 pounds
B
If the stack temperature
is higher than normal, this could indicate __________.
high feed water
pressure
too much excess
air
external boiler
casing leakage
low fuel oil back
pressure
A
When testing boiler
flue gas with a chemical absorption apparatus, to obtain accurate results
__________.
prevent any air
from contaminating the gas sample
analyze for nitrogen
content before oxygen content
run each analysis
for at least 3 minutes
purge the apparatus
with air before use
C
The absence of
carbon monoxide in the flue gas of a boiler indicates __________.
contaminated fuel
oil
low carbon content
of fuel
efficient combustion
insufficient air
C
When burning fuel
oil in a boiler, a high CO2 content is desired in the stack gas because
__________.
efficient combustion
is indicated and the heat liberated is equal to the heat produced by the
formation of CO
less excess air
is required to produce CO2 than CO
more heat is liberated
by the production of CO2 than CO
efficient combustion
is indicated even though the heat liberated is less than the heat produced
by burning to CO
B
Assuming all burners
are clean and the fuel oil is at the correct temperature, it is considered
good practice to adjust the excess air until a light brown haze is obtained.
With the aid of a chemical based flue gas analyzer, the percentage readings
(not necessarily in order) should indicate.
low CO2, no O2,
and high CO
no CO, low O2,
and high CO2
high O2, low CO,
and low CO2
high CO, high
CO2, and no O2
B
A mechanical carbon
dioxide recorder operates by detecting the difference between air and the
__________.
soot content of
the flue gases
specific weight
of the flue gases
color of boiler
flue gases
temperature of
the flue gases
D
A flue gas analysis
is performed to determine the __________.
specific heat
of combustion products
percentage of
nitrogen by volume
carbon content
of the fuel being burned
correct fuel/air
ratio for efficient combustion
A
Which of the following
chemicals is used in an Orsat apparatus to absorb carbon dioxide?
Potassium hydroxide
Cuprous chloride
Pyrogallic acid
Potassium chromate
D
If an analysis
of boiler flue gas determines there is no excess air for combustion, you
should expect the nitrogen content of the flue gas to be approximately __________.
10.5 (%)
14.0 (%)
21.0 (%)
79.0 (%)
B
Generally, a 12%
to 14% content of carbon dioxide in boiler flue gases indicates __________.
too much excess
air
proper combustion
of the fuel oil
a high vanadium
content in the fuel oil
carbon deposits
in the uptakes
B
Which of the following
fuel oil characteristics establishes the danger point when transferring,
pumping, and firing procedures are concerned?
Viscosity
Flash point
Specific gravity
Fire point
A
Which characteristic
of fuel oil is the most significant when determining the temperature to
which the fuel oil must be heated for proper atomization?
Viscosity
Flash point
Specific gravity
Pour point
D
Which of the following
actions should be taken FIRST when water is found in the fuel oil settling
tank?
Shift to alternate
or standby fuel oil service pump.
Determine the
extent of water contamination by reading the pneumercators.
Sound the settling
tank with water indicating paste.
Shift pump suction
to an alternate settling tank.
D
When you are transferring
fuel oil to the settling tanks, precautions to be observed should include
__________.
plugging gooseneck
tank vents to prevent accidental overflow
maintaining a
high transfer rate until a slight trickle of oil is observed flowing from
the overflow line
maintaining a
supply of chemical dispersant to cleanup minor oil spills adjacent to the
ship
sounding the tanks
frequently and reducing the transfer rate as the level approaches maximum
fill
A
When you are transferring
fuel oil from one double bottom tank to another, precautions to be observed
should include __________.
sounding the tanks
frequently and reducing the transfer rate while topping off
maintaining a
supply of chemical dispersant to cleanup minor oil spills adjacent to the
ship
plugging gooseneck
tank vents to prevent accidental overflow
maintaining a
high transfer rate until a slight trickle of oil is observed flowing from
the overflow line
C
Which of the pumps
listed takes fuel oil suction from the double bottom tanks and discharges
it to the settling tanks?
Fuel oil service
pump
Centrifugal type
general service pump
Fuel oil transfer
pump
Settler service
pump
C
Fuel oil is transferred
to the settling tanks for __________.
heating to the
correct temperature for proper burner atomization
purging of any
large air bubbles that have formed
heating to allow
water and sediment to settle out
the purpose of
removing any volatile gases present in the fuel
B
The process of
breaking up fuel oil into fine particles to ensure good combustion is called
__________.
settling
atomization
straining
pumping
C
Which of the terms
listed represents the ratio between the highest and lowest fuel oil pressure
at which the burners will remain ignited?
Modulating band
ratio
Firing range ratio
Turndown ratio
Air/fuel ratio
D
The entire unit
which houses the burner, air scoop, air doors and bladed cone is correctly
called the __________.
air duct assembly
burner assembly
atomizer assembly
register assembly
D
The component
labeled "F" as shown in the illustration is___________. Illustration
SG-
a permanently
installed Orsat apparatus
one of the retractable
soot blower elements
a regenerative
air heater
one of the main
burner assemblies
D
The property of
a fuel oil which is a measurement of its available energy, is known as its
__________.
viscosity index
cetane number
cetane index
heating value
D
Which of the significant
combustible elements of fuel oil is a major source of boiler corrosion?
Hydrogen
Oxygen
Carbon
Sulphur
C
The most harmful
slag forming compounds found in fuel oils are __________.
calcium and silica
potassium and
nickel
vanadium and sodium
iron and sulphur
A
The minimum temperature
requirements for fuel oil in storage tanks is related to the __________.
pumpability of
the oil
size of the containment
area in case of overflow
fire point of
the oil
size of the vents
B
Which constituent
of fuel oil determines the specific heat?
Sulphur
Hydrocarbons
Oxygen
Nitrogen
B
Which combustible
element in fuel oil is considered a significant and major source of air
pollution?
Hydrogen
Sulfur
Vanadium
Nitrogen
C
The BTU value
of fuel oil is determined by a/an __________.
open cup test
hydrometer
calorimeter
viscosimeter
D
The flash point
of a residual fuel oil should be used to determine the highest temperature
to which the oil may be heated __________.
in the recirculating
line
for centrifuging
for atomizing
in a storage tank
D
When testing boiler
flue gas with a chemical absorption apparatus, to obtain accurate results
__________.
run each analysis
for at least 3 minutes
analyze for nitrogen
content before oxygen content
purge the apparatus
with air before use
prevent any air
from contaminating the gas sample
B
The absence of
carbon monoxide in the flue gas of a boiler indicates __________.
low carbon content
of fuel
efficient combustion
insufficient air
contaminated fuel
oil
D
When burning fuel
oil in a boiler, a high CO2 content is desired in the stack gas because
__________.
efficient combustion
is indicated even though the heat liberated is less than the heat produced
by burning to CO
efficient combustion
is indicated and the heat liberated is equal to the heat produced by the
formation of CO
less excess air
is required to produce CO2 than CO
more heat is liberated
by the production of CO2 than CO
B
A mechanical carbon
dioxide recorder operates by detecting the difference between air and the
__________.
soot content of
the flue gases
specific weight
of the flue gases
color of boiler
flue gases
temperature of
the flue gases
D
A flue gas analysis
is performed to determine the __________.
percentage of
nitrogen by volume
carbon content
of the fuel being burned
specific heat
of combustion products
correct fuel/air
ratio for efficient combustion
D
Which of the following
chemicals is used in an Orsat apparatus to absorb carbon dioxide?
Potassium chromate
Cuprous chloride
Pyrogallic acid
Potassium hydroxide
C
If an analysis
of boiler flue gas determines there is no excess air for combustion, you
should expect the nitrogen content of the flue gas to be approximately __________.
10.5 (%)
21 (%)
79 (%)
14 (%)
C
Generally, a 12%
to 14% content of carbon dioxide in boiler flue gases indicates __________.
a high vanadium
content in the fuel oil
carbon deposits
in the uptakes
proper combustion
of the fuel oil
too much excess
air
A
The temperature
of the fuel oil received during bunkering operations is critical in determining
the __________.
expansion space
to leave in a tank
flash point at
which the fuel will burn
rate at which
the fuel can be pumped during transfer operations
temperature to
which the fuel must be heated
A
When you are transferring
fuel oil to the settling tanks, precautions to be observed should include
__________.
sounding the tanks
frequently and reducing the transfer rate as the level approaches maximum
fill
maintaining a
high transfer rate until a slight trickle of oil is observed flowing from
the overflow line
plugging gooseneck
tank vents to prevent accidental overflow
maintaining a
supply of chemical dispersant to cleanup minor oil spills adjacent to the
ship
A
When you are transferring
fuel oil from one double bottom tank to another, precautions to be observed
should include __________.
sounding the tanks
frequently and reducing the transfer rate while topping off
maintaining a
supply of chemical dispersant to cleanup minor oil spills adjacent to the
ship
maintaining a
high transfer rate until a slight trickle of oil is observed flowing from
the overflow line
plugging gooseneck
tank vents to prevent accidental overflow
B
Which of the pumps
listed takes fuel oil suction from the double bottom tanks and discharges
it to the settling tanks?
Centrifugal type
general service pump
Fuel oil transfer
pump
Settler service
pump
Fuel oil service
pump
A
The main reason
for having a low suction line on the fuel oil service or settling tanks
is to __________.
facilitate water
removal
prevent loss of
suction during rough weather
decrease suction
head on the pump
increase the amount
of fuel available for use
A
Which of the following
actions should be taken FIRST when water is found in the fuel oil settling
tank?
Shift pump suction
to an alternate settling tank.
Shift to alternate
or standby fuel oil service pump.
Determine the
extent of water contamination by reading the pneumercators.
Sound the settling
tank with water indicating paste.
A
Fuel oil is transferred
to the settling tanks for __________.
heating to allow
water and sediment to settle out
heating to the
correct temperature for proper burner atomization
the purpose of
removing any volatile gases present in the fuel
purging of any
large air bubbles that have formed
B
The fins on the
tubes of a fin type fuel oil heater are provided to __________.
prevent tube erosion
increase heater
efficiency
clean the fuel
oil
decrease fuel
flow
C
The valve located
between the fuel oil header and the burner valve is known as the __________.
header valve
register valve
root valve
return valve
B
Strainers are
installed in boiler fuel oil service lines to __________.
adsorb water
remove solids
absorb contaminants
decrease viscosity
C
The boiler fuel
oil service pump normally takes suction from the __________.
double bottom
fuel tanks
contaminated drain
inspection tank
fuel oil settler
tank
fuel oil heater
discharge
C
The viscosity
of a residual fuel oil is measured in Saybolt __________.
Milliliters Universal
Minutes Universal
Seconds Furol
Millimeters Universal
D
The relief valve
on the discharge side of the fuel oil service pump may discharge directly
to the suction side of the pump, or to the __________.
oil header return
line
fuel oil heater
inlet
double bottom
fuel tank
fuel oil settling
tank
A
Pumps normally
used for fuel oil service are __________.
positive displacement
rotary pumps
nonvented plunger
pumps
two-stage centrifugal
pumps
explosion proof
gear pumps
A
All fuel oil service
pumps are equipped with a __________.
remote means of
stopping the pump
combustion control
valve on the discharge side
relief valve on
the suction side
direct suction
to the double bottom tanks
B
Fuel oil solenoid
valves at the burner fronts should be of the manual reset type to __________.
permit the operator
to secure each burner during a blackout
prevent the furnace
filling with oil after restoration of power
permit the operator
to secure each burner after a blackout
prevent the furnace
filling with oil during a power failure
B
All oil-fired
main propulsion burners with automatic safety control systems must automatically
close the burner valve when __________.
the flame in boiler
furnace is confirmed
actuated by a
boiler safety trip
the burner is
properly seated
starting "trial
for ignition"
D
The advantage
of a counter flow fuel oil heater, as compared to a parallel flow fuel oil
heater, is that the counter flow heater __________.
has a larger heat
transfer area providing greater heat transfer
is not subject
to coking if overheated
has thinner tube
walls providing greater heat transfer
produces a higher
oil temperature at any given steam temperature
B
A flame scanner
installed in modern boiler combustion control systems, functions to __________.
monitor the stack
for soot fires
monitor the intensity
of the burner flame
regulate burner
fuel oil pressure
regulate the air
flow to the furnace
C
When warming up
a fuel oil service system, you should open the steam supply to the fuel
oil heaters __________.
before you start
the fuel oil service pump
before you open
the recirculating valve
after you start
the fuel oil service pump
only if the settlers
are incapable of heating the oil
D
Valve "H"
shown in the illustration, functions to __________. Illustration SG-
prevent a backflow
from the manifold
recirculate fuel
oil during start-up
regulate the amount
of fuel burned
provide a quick
shut off of fuel to the boiler
A
In the majority
of marine power plants, the fuel oil heater installations are divided into
several units because __________.
plant operation
can be continued while repairs are being made to a defective unit
auxiliary steam
is better utilized in this system
oil leakage into
the condensate system is less likely with multiple system
more heating is
required for lower loads
C
Fine adjustments
to a boiler combustion control system, to bring about near perfect combustion,
should be made by manually adjusting the __________.
forced draft fan
dampers
air volume regulators
fuel/air ratio
knob
fuel oil back
pressure
C
While trying to
light off a burner on a semi-automated boiler, you note that the fuel oil
solenoid valve at the burner will not stay open. Which of the following
conditions could cause this problem?
The fuel oil pressure
at that burner is too high.
The solenoid coil
is energized causing the valve to remain closed.
The forced draft
air supply has failed.
The flame scanner
is adjusted for excessive time delay in the ignition trial circuit.
A
A combustion control
system diaphragm type air flow transmitter receives its high pressure signal
from the boiler __________.
wind box
furnace
fan discharge
smoke box
C
The last two digits
stamped on a fuel oil atomizer sprayer plate represents the cross-sectional
area ratios of the tangential slots and orifice. This ratio determines the
__________.
capacity of the
atomizer
density of the
oil spray
angle of the cone
degree of atomization
A
What is indicated
by the code number 32Y20 stamped on a burner sprayer plate?
Sprayer plate
orifice was made with a size 32 drill.
Sprayer plate
requires a size 20 tip.
Sprayer plate
orifice area is 0.32 square inch.
Sprayer plate
requires a minimum of 20 psi fuel pressure.
C
In addition to
a nozzle, a fuel oil atomizer uses which of the listed parts?
Burner cone
Air cone
Sprayer plate
Ignition electrode
A
Which atomizing
sprayer plate has the largest capacity?
2 PCRS
A
The number '29'
on a fuel oil burner sprayer plate marked '' indicates the __________.
orifice size
slot cross-sectional
area
whirling chamber
size
cross-sectional
area ratio
A
The primary purpose
of the sprayer plate in a mechanical atomizing oil burner is to __________.
produce a fine,
swirling, uniform fuel mist
assist in mixing
atomizing steam with the fuel
completely mix
air with the fuel
prevent primary
air mixing with the fuel
A
The amount of
oil atomized by a straight mechanical fuel oil burner depends on the sprayer
plate size and the __________.
fuel oil pressure
forced draft pressure
oil return pressure
furnace air pressure
B
The illustrated
burner atomizer assembly is __________. Illustration SG-
used in a return
flow type burner management system
straight mechanical
an example of
a rotary cup type atomizer
used only for
variable load steam atomization
C
In a steam assist
fuel oil atomizer, the steam pressure is higher than the oil pressure at
__________.
design boiler
load
high fuel viscosity
minimum boiler
load
low fuel viscosity
B
In most installations,
the firing rate of a boiler using steam atomization is indicated by the
__________.
fuel oil return
pressure
fuel oil supply
pressure
burner register
opening
steam atomization
temperature
A
In a steam assist
atomizer, the fuel oil/steam mix takes place entirely within the __________.
mixing chamber
fuel oil swirlers
tangential slots
whirling chamber
D
Compared to the
return flow oil burner system, an internally mixed steam atomizer requires
__________.
higher air velocity
higher fuel oil
viscosity
greater turbulence
in the air/oil stream
less excess air
A
The variable capacity
pressure atomizing fuel oil burner functions to __________.
provide a wide
range of combustion
maintain smokeless
fuel oil atomization
maintain a constant
fuel temperature
provide a constant
fuel return pressure
B
Boilers equipped
with steam atomizers can operate over a wide load range without cutting
burners in and out because __________.
steam maintains
the oil at the fire point temperature
steam velocity
aids in the atomizing of fuel oil over a wide range of fuel pressures
atomizing steam
pressure is held constant for all load ranges
it is not necessary
to regulate fuel oil pressure at the burners with this system
D
According to the
illustration, what part number identifies the "air door handle"?
Illustration SG-
4
6
7
12
D
Which of the following
represents the function of the diffuser used with a mechanical atomizing
oil burner?
Complete the vaporization
of the fuel for combustion.
Control the amount
of secondary combustion air.
Finely divide
the fuel particles into a cone-shaped spray.
Provide flame
stability at the atomizer tip.
A
According to the
illustration, what part number identifies the "igniter"? Illustration
SG-
2
3
7
9
D
What is the purpose
of the movable air doors in an air register?
Maintain air flow
across the forced draft fan.
Support the burner
distance piece.
Regulate the temperature
of air entering the furnace.
Function to open
and close the register.
B
According to the
illustration, what part number identifies the "air doors"? Illustration
SG-
1
3
9
4
D
In an air register
assembly, the majority of air passes through the __________.
atomizer assembly
diffuser or impeller
distance piece
stationary air
foil or blade cone
C
According to the
illustration, what part number identifies the "diffuser"? Illustration
SG-
1
3
9
7
B
The purpose of
a 'peep' hole in the boiler casing is to __________.
check for excess
smoke in the stack
examine the condition
of the flame
examine the condition
of the refractory cones
check the operation
of the soot blowers
D
Which of the following
represents the proper color of the flame end farthest from the boiler burner
during normal operations?
Dark brown
Dazzling white
Light brown haze
Bright yellow
or orange
A
Which of the following
procedures represents the proper care of unused burners during low load
conditions?
They should be
removed, cleaned and stored in the rack on the burner bench.
They may be left
in place, but only if they are clean and if fuel oil is recirculated to
provide cooling.
They may be left
in place, with fuel and steam secured as long as they are not fouled.
They should be
removed, cleaned, refitted with smaller tips and reinstalled to be ready
for immediate use.
D
To obtain the
best mixing of air and fuel with a fuel oil atomizer, you need to adjust
the __________.
primary and secondary
air cones for desired air flow
total air volume
admitted to the boiler furnace
diffuser to the
desired flow
atomizer position
using the distance piece
B
Which precaution
should be observed to prevent damage to the fuel oil service pump when warming
up the fuel service system?
Bypass the fuel
oil meter so that recirculating oil does not register.
Close the recirculating
valve when the proper atomization temperature is reached.
Strip all water
from the fuel oil settlers.
Heat the fuel
oil in the settlers to the atomization temperature.
D
If one burner
of a group of operating steam atomizing burners in a steaming boiler is
cut out, the register doors for that burner should be __________.
left wide open
closed halfway
left cracked open
closed tightly
C
To properly remove
the burner tip nut from the burner barrel, the barrel should be __________.
clamped in a machinist's
vice on the work bench
fixed in the burner
stowage rack
held by the fixture
on the burner cleaning bench
removed from the
gooseneck before removing the tip nut
D
In a boiler furnace,
incomplete combustion due to insufficient air yields an excess amount of
__________.
sulfur dioxide
carbon dioxide
nitrogen oxide
carbon monoxide
B
Insufficient air
for combustion in a boiler furnace could result in a __________.
0% carbon monoxide
level
black stack smoke
emission
white incandescent
flame
high flame temperature
C
If a boiler is
smoking black and increasing the boiler front air box pressure does not
reduce the smoke, the cause can be __________.
forced draft fan
failure
high ambient air
temperature
dirty atomizers
heavy soot on
tubes
C
Throttling the
burner air register of a lit burner could result in__________.
excess combustion
temperature in the furnace
carbon deposits
on the register doors
carbon deposits
on the furnace walls
too much excess
air for combustion
A
Accumulation of
fuel oil in the boiler double casing could be caused by _________.
dripping atomizers
leaking fuel oil
strainers
high atomizing
steam pressure
faulty steam atomizer
return traps
D
Excessive accumulation
of carbon deposits on a boiler burner throat ring and diffuser could result
in __________.
a reduced boiler
fuel oil pressure
increased heat
transfer and overheating
too much excess
combustion air
a decrease in
boiler efficiency
D
When a boiler
flareback occurs, you should __________.
reduce the forced
draft blower speed
increase the fuel
oil supply pressure
take the boiler
off the line
close the master
fuel oil valve
B
Insufficient combustion
air supply will cause an atomizer flame to appear as a __________.
ragged flame
dull red flame
with black streaks
pointed flame
light yellow flame
with white streaks
A
Boiler furnace
brickwork can be fractured and broken by thermal shock caused by __________.
leaving the registers
open on a hot boiler
load changes on
the boiler while answering bells
allowing the furnace
to cool too slowly
cold feed water
passing through the boiler economizer
B
Which of the conditions
listed can cause the flame of a mechanically atomized burner to be blown
away from the burner tip when you are attempting to light off?
Insufficient excess
air is being supplied to the furnace.
The diffuser is
burned out.
Fuel oil viscosity
is too low.
The secondary
air cone is improperly adjusted.
B
Poor atomization
accompanied by an elongated flame from a steam atomization burner is MOST
likely caused by __________.
improper operation
of traps in atomizing steam return piping
the fuel oil temperature
being too low
the forced draft
fan too slow for the boiler load
an improper Cetane
number
D
Fluctuations in
the atomizing steam pressure at the burners could be caused by a/an __________.
partially closed
atomizing fuel valve
partially opened
recirculating valve
incorrectly assembled
air register
malfunctioning
steam trap in the atomizing steam system
D
In a multi-burner
firebox, a burner tip with a worn and enlarged orifice will __________.
cause a high fuel
oil return line back pressure
cause smokeless
and flameless combustion
have no effect
on the flow of oil if the proper pressure is maintained
result in an uneven
flow of oil through the burner
B
If the temperature
of the fuel oil entering an atomizer is too low, the burner will __________.
require more fuel
for atomization
produce heavy
black smoke at any load condition
produce smoke
white
require more excess
air for combustion
D
If one fuel oil
strainer of a duplex unit becomes clogged while the vessel is steaming at
sea, the FIRST action should be to __________.
clean the dirty
strainer as quickly as possible
open the strainer
bypass valve
stop the fuel
oil service pump
change the oil
flow over to the clean side
D
A leaky fuel oil
heater relief valve could be indicated by an increase in the __________.
contaminated drain
tank level
fuel oil service
pump pressure
sludge tank level
discharge piping
temperature
B
Condensate accumulation
in the steam side of a fuel oil heater could result in __________.
water contamination
of the fuel oil
reduced heating
capacity in an operating heater
annealing of the
heater tube bundles
scale accumulation
in an operating heater
C
The rate of fouling
on the oil side of a fuel oil heater is inversely related to the __________.
pressure on the
oil in the heater
shape of the heating
coils in the heater
flow rate of fuel
oil through the heater
quality of steam
flowing through the heater
C
If oil is found
in the main fuel oil heater steam drain system, which of the actions listed
should be taken first?
Change over fuel
supply to diesel fuel.
Bottom blow the
boiler using the continuous blow line.
Shift over to
the standby heater and monitor contaminated drain tank for additional traces
of oil.
Shift over to
the low fuel oil suction on the day tank.
A
As found in a
basic pneumatic automatic combustion control system, the function of a standardizing
relay is to __________.
introduce a control
for maintaining constant steam pressure regardless of boiler load
introduce a control
for maintaining constant superheated steam temperature regardless of boiler
load
control the boiler
drum water level within acceptable limits regardless of the load
provide a backup
means for manual control of the system
B
When firing a
boiler in local manual control, an increase in boiler load must be accompanied
by a/an __________.
decrease in the
forced draft air pressure before a decrease in the fuel oil flow
increase in the
forced draft air pressure before an increase in the fuel oil flow
increase in the
fuel oil flow before an increase in the forced draft pressure
increase or a
decrease in the fuel oil flow and forced draft air pressure simultaneously
A
In an automatically
fired boiler, the steam pressure regulator controls the supply of fuel oil
to the burners by responding to variations in the __________.
steam header pressure
burner flame intensity
steam drum water
level
master fuel oil
solenoid valve position
B
In automated boiler
operations, a dirty flame scanner will most likely result in __________.
loss of forced
draft air
securing fuel
oil to the burner
incomplete purge
cycle
increased fuel
oil consumption
C
When the flame
scanner senses flame failure during boiler operation, which of the listed
events will occur FIRST?
The automatic
purge cycle commences.
The 'trial for
ignition' period commences.
The fuel oil solenoid
valve is de-energized.
The fuel oil service
pump is stopped.
B
A photoelectric
cell is installed in an oil fired boiler safeguard system to introduce proper
resistance values to the electronic control circuit. This device is primarily
sensitive to
light emitted
from the back wall incandescent brickwork
the blue portion
of the flame spectrum
light emitted
from the front wall incandescent brickwork
the orange portion
of the flame spectrum
C
Combustion control
systems on automatic boilers are designed to prevent immediate burner ignition
after a normal or safety shutdown in order to allow time for.
the fuel pump
to start
the drum level
to equalize
the furnace to
be purged
electric charge
buildup in the igniter
B
Which of the following
represents a significant system limitation to be aware of when a burner
management system is operated in the 'HAND' mode?
The burner is
not capable of maintaining a high firing rate when the boiler is in the
'HAND' mode.
Some boiler safety
interlocks are bypassed when the boiler is 'HAND' fired.
The burner sequence
control is fully automatic even in the 'HAND' mode.
The flame failure
alarm cannot function when the boiler is 'HAND' fired.
A
In automatic combustion
control systems, increasing or decreasing a loading pressure by a set amount
is called __________.
biasing
relaying
loading
transmitting
C
If an automatically
fired burner ignites, but repeatedly goes out within two seconds, the cause
could be a/an __________.
faulty pressure
signal to the time delay relay circuit
excessively high
fuel oil temperature
dirty flame scanner
window
burned out solenoid
coil in the low fire oil valve
C
Modern day boiler
automation allows bypassing the "flame safeguard" system to permit
a burner to have a "trial for ignition" period during burner light
off. This period may not exceed __________.
5 seconds
10 seconds
15 seconds
30 seconds
A
In a boiler automation
system, if a burner fuel oil solenoid valve continually trips closed under
normal steaming conditions, you should __________.
secure the burner
and determine the cause of the valve failure
wedge the valve
in the open position and report it to the chief engineer
wedge the valve
in the open position and reduce the fuel oil pressure at that burner
bypass the solenoid
valve and enter the fact in the logbook
A
While your vessel
is steaming with one boiler, the automatic combustion control system sensing
line for the idle boiler is accidentally opened. How will this affect the
steaming boiler?
The steam pressure
will rise.
The water level
will drop.
The water level
will rise.
The steam pressure
will drop.
C
The relief valve
on the discharge side of the fuel oil service pump may discharge directly
to the suction side of the pump, or to the __________.
double bottom
fuel tank
fuel oil heater
inlet
fuel oil settling
tank
oil header return
line
B
Pumps normally
used for fuel oil service are __________.
explosion proof
gear pumps
positive displacement
rotary pumps
nonvented plunger
pumps
two-stage centrifugal
pumps
A
Valve "H"
shown in the illustration, functions to __________. Illustration SG-
provide a quick
shut off of fuel to the boiler
recirculate fuel
oil during start-up
prevent a backflow
from the manifold
regulate the amount
of fuel burned
D
The valve located
between the fuel oil header and the burner valve is known as the __________.
return valve
register valve
header valve
root valve
D
The primary purpose
of the sprayer plate in a mechanical atomizing oil burner is to __________.
assist in mixing
atomizing steam with the fuel
prevent primary
air mixing with the fuel
completely mix
air with the fuel
produce a fine,
swirling, uniform fuel mist
C
The amount of
oil atomized by a straight mechanical fuel oil burner depends on the sprayer
plate size and the __________.
oil return pressure
furnace air pressure
fuel oil pressure
forced draft pressure
D
The illustrated
burner atomizer assembly is __________. Illustration SG-
an example of
a rotary cup type atomizer
used only for
variable load steam atomization
used in a return
flow type burner management system
straight mechanical
D
In a steam assist
fuel oil atomizer, the steam pressure is higher than the oil pressure at
__________.
design boiler
load
high fuel viscosity
low fuel viscosity
minimum boiler
load
B
In most installations,
the firing rate of a boiler using steam atomization is indicated by the
__________.
burner register
opening
fuel oil supply
pressure
fuel oil return
pressure
steam atomization
temperature
C
In a steam assist
atomizer, the fuel oil/steam mix takes place entirely within the __________.
fuel oil swirliers
whirling chamber
mixing chamber
tangential slots
B
Compared to the
return flow oil burner system, an internally mixed steam atomizer requires
__________.
greater turbulence
in the air/oil stream
less excess air
higher air velocity
higher fuel oil
viscosity
D
Boilers equipped
with steam atomizers can operate over a wide load range without cutting
burners in and out because __________.
atomizing steam
pressure is held constant for all load ranges
steam maintains
the oil at the fire point temperature
it is not necessary
to regulate fuel oil pressure at the burners with this system
steam velocity
aids in the atomizing of fuel oil over a wide range of fuel pressures
B
A boiler has a
steam delivery capacity of 100,000 pounds per hour, and is equipped with
four steam atomizing burners. If the load range of the burners is 4 to 1,
this means that __________.
the boiler may
be operated down to 25,000 pounds per hour only after three burners are
secured
the boiler may
be operated down to 25,000 pounds per hour without securing any burners
all four burners
combined can supply up to 400,000 pounds of steam per hour
if two burners
are operating, steam output will be a minimum of 50,000 pounds per hour
C
According to the
illustration, what part number identifies the "air door handle"?
Illustration SG-
6
4
12
7
B
According to the
illustration, what part number identifies the "igniter"? Illustration
SG-
3
2
9
7
A
In an air register
assembly, the majority of air passes through the __________.
stationary air
foil or blade cone
distance piece
diffuser or impeller
atomizer assembly
D
According to the
illustration, what part number identifies the "diffuser"? Illustration
SG-
7
3
1
9
D
The purpose of
a 'peep' hole in the boiler casing is to __________.
examine the condition
of the refractory cones
check for excess
smoke in the stack
check the operation
of the soot blowers
examine the condition
of the flame
B
The fins on the
tubes of a fin type fuel oil heater are provided to __________.
decrease fuel
flow
increase heater
efficiency
prevent tube erosion
clean the fuel
oil
B
When warming up
a fuel oil service system, you should open the steam supply to the fuel
oil heaters __________.
before you start
the fuel oil service pump
after you start
the fuel oil service pump
only if the settlers
are incapable of heating the oil
before you open
the recirculating valve
B
Boiler furnace
brickwork can be fractured and broken by thermal shock caused by __________.
allowing the furnace
to cool too slowly
leaving the registers
open on a hot boiler
load changes on
the boiler while answering bells
cold feed water
passing through the boiler economizer
A
Which of the conditions
listed can cause the flame of a mechanically atomized burner to be blown
away from the burner tip when you are attempting to light off?
The diffuser is
burned out.
Insufficient excess
air is being supplied to the furnace.
Fuel oil viscosity
is too low.
The secondary
air cone is improperly adjusted.
D
Fluctuations in
the atomizing steam pressure at the burners could be caused by a/an __________.
partially opened
recirculating valve
partially closed
atomizing fuel valve
incorrectly assembled
air register
malfunctioning
steam trap in the atomizing steam system
B
In a multi-burner
firebox, a burner tip with a worn and enlarged orifice will __________.
cause smokeless
and flameless combustion
result in an uneven
flow of oil through the burner
have no effect
on the flow of oil if the proper pressure is maintained
cause a high fuel
oil return line back pressure
D
If the temperature
of the fuel oil entering an atomizer is too low, the burner will __________.
require more fuel
for atomization
produce smoke
white
require more excess
air for combustion
produce heavy
black smoke at any load condition
B
A leaky fuel oil
heater relief valve could be indicated by an increase in the __________.
sludge tank level
discharge piping
temperature
contaminated drain
tank level
fuel oil service
pump pressure
B
Condensate accumulation
in the steam side of a fuel oil heater could result in __________.
scale accumulation
in an operating heater
reduced heating
capacity in an operating heater
water contamination
of the fuel oil
annealing of the
heater tube bundles
D
The rate of fouling
on the oil side of a fuel oil heater is inversely related to the __________.
shape of the heating
coils in the heater
quality of steam
flowing through the heater
pressure on the
oil in the heater
flow rate of fuel
oil through the heater
C
If oil is found
in the main fuel oil heater steam drain system, which of the actions listed
should be taken first?
Change over fuel
supply to diesel fuel.
Bottom blow the
boiler using the continuous blow line.
Shift over to
the standby heater and monitor contaminated drain tank for additional traces
of oil.
Shift over to
the low fuel oil suction on the day tank.
C
Flame scanners
are used with boiler combustion control systems to monitor flame quality
and to __________.
secure the fuel
oil service pump in the event of a floor fire
regulate the fuel/air
ratio controller for more efficient combustion
shut off the fuel
supply if flame failure is detected
secure the forced
draft fan in the event of a flame failure
D
The photoelectric
cell installed as part of the combustion safety controls of an automatically
fired boiler will __________.
close the control
circuit upon sensing a flame failure
open the control
circuit upon sensing an intense flame
control the modulating
pressure control circuit
sense light from
the burner flame
B
Which of the following
represents a significant system limitation to be aware of when a burner
management system is operated in the 'HAND' mode?
The flame failure
alarm cannot function when the boiler is 'HAND' fired.
Some boiler safety
interlocks are bypassed when the boiler is 'HAND' fired.
The burner sequence
control is fully automatic even in the 'HAND' mode.
The burner is
not capable of maintaining a high firing rate when the boiler is in the
'HAND' mode.
A
In automatic combustion
control systems, increasing or decreasing a loading pressure by a set amount
is called __________.
biasing
loading
relaying
transmitting
B
As found in a
basic pneumatic automatic combustion control system, the function of a standardizing
relay is to __________.
introduce a control
for maintaining constant superheated steam temperature regardless of
boiler load
introduce a control
for maintaining constant steam pressure regardless of boiler load
provide a backup
means for manual control of the system
control the boiler
drum water level within acceptable limits regardless of the load
A
In an automatically
fired boiler, the steam pressure regulator controls the supply of fuel oil
to the burners by responding to variations in the __________.
steam header pressure
steam drum water
level
burner flame intensity
master fuel oil
solenoid valve position
D
Fine adjustments
to a boiler combustion control system, to bring about near perfect combustion,
should be made by manually adjusting the __________.
fuel oil back
pressure
forced draft fan
dampers
air volume regulators
fuel/air ratio
knob
B
While trying to
light off a burner on a semi-automated boiler, you note that the fuel oil
solenoid valve at the burner will not stay open. Which of the following
conditions could cause this problem?
The flame scanner
is adjusted for excessive time delay in the ignition trial circuit.
The forced draft
air supply has failed.
The fuel oil pressure
at that burner is too high.
The solenoid coil
is energized causing the valve to remain closed.
D
While your vessel
is steaming with one boiler, the automatic combustion control system sensing
line for the idle boiler is accidentally opened. How will this affect the
steaming boiler?
The water level
will drop.
The water level
will rise.
The steam pressure
will drop.
The steam pressure
will rise.
D
In a boiler automation
system, if a burner fuel oil solenoid valve continually trips closed under
normal steaming conditions, you should __________.
wedge the valve
in the open position and reduce the fuel oil pressure at that burner
bypass the solenoid
valve and enter the fact in the logbook
wedge the valve
in the open position and report it to the chief engineer
secure the burner
and determine the cause of the valve failure
C
If an automatically
fired burner ignites, but repeatedly goes out within two seconds, the cause
could be a/an __________.
excessively high
fuel oil temperature
faulty pressure
signal to the time delay relay circuit
dirty flame scanner
window
burned out solenoid
coil in the low fire oil valve
A
Modern day boiler
automation allows bypassing the "flame safeguard" system to permit
a burner to have a "trial for ignition" period during burner light
off. This period may not exceed __________.
15 seconds
30 seconds
10 seconds
5 seconds
C
Which of the following
statements represents the primary function of handholes used on a boiler?
To allow access
into the steam and water drum.
To provide access
for cleaning out the firebox.
To allow access
into the headers.
To allow access
for cleaning in the stack.
C
In what section
of a boiler would you find a steam quality of 90%?
Last pass of the
superheater
Superheater outlet
Steam drum
Desuperheater
outlet
B
Circulation of
water and the steam/water mixture within a natural circulation boiler is
retarded by __________.
back pressure
in the steam drum acting on the user tubes
fluid friction
in the downcomers, drums, generating tubes, and headers
large changes
in steam density
high feed water
pressure
C
Arrow "B"
shown in the illustration indicates the_________. Illustration SG-
retractable soot
blower opening
uptakes
combustion air
inlet
regenerative air
heater
B
How is boiler
water forced to circulate faster in accelerated natural circulation boilers
as compared to free natural circulation boilers?
Increasing the
density of the water.
Increasing the
inclined angle of the generating tubes.
Increasing the
surface area of the economizer exposed to the combustion gases.
Installing a water
circulating pump, such as a hydrokineter.
B
Steam drum water
level indicators must be calibrated to compensate for density differences
between the indicated drum water level, and the actual drum water level.
If no compensation is made, the indicator will show a __________.
lower level than
exists in the drum with the error becoming greater as the drum pressure
decreases
lower level than
exists in the drum with the error becoming greater as the drum pressure
increases
higher level than
exists in the drum with the error becoming greater as the drum pressure
decreases
higher level than
exists in the drum with the error becoming greater as the drum pressure
increases
B
Reaching which
'end point' will result in the most severe damage to the boiler?
Combustion
Circulation
Atomization
Carryover
A
As compared with
a typical front fired boiler, which of the listed conditions represents
an advantage of a top fired boiler?
More uniform heat
distribution and gas dwell is obtained within the furnace.
No division tube
wall separating the convection and radiant sections of the furnace is ever
required.
A lower fuel flow
rate can be allowed, thus increasing economy.
Superheating diaphragms
may be omitted.
A
Most main propulsion
boilers are designed to produce.
saturated and
superheated steam
saturated steam
only
superheated steam
only
superheated and
supercritical steam
B
Overheating of
the generating tubes will occur when a boiler reaches its end point of __________.
combustion
circulation
moisture carryover
evaporation
D
The required number
of pounds of steam generated per hour to develop contract shaft horsepower
and maintain the specified pressures and temperatures in the plant, when
divided by the number of installed boilers, will give the __________.
efficiency of
each fire room
overload capacity
for each boiler
efficiency of
each boiler
full power capacity
of each boiler
A
A natural circulation
water-tube boiler, with one or more water drums, would be classified as
a/an.
drum-type boiler
accelerated natural
circulation boiler
header-type boiler
controlled circulation
boiler
A
On a boiler safety
valve, the blowdown adjusting ring is locked in place by a __________.
set screw
locknut
wire seal
cotter pin
A
One of the important
functions of the superheater safety valves is to __________.
protect the superheater
from overheating
maintain a constant
steam flow in the auxiliary steam line
maintain a constant
steam flow in the desuperheater
protect the desuperheater
from overheating
D
When excessive
static boiler pressure has resulted in the initial lift of the valve disc,
a huddling chamber safety valve will continue to lift open as a result of
___________,
steam pressure
transmitted through a pipe connected to the superheater outlet
an increase in
steam velocity through an adjustable orifice ring
the resulting
reactive force created by the rapid expansion of escaping steam
steam pressure
acting on the enlarged area of projecting lip or ring
C
Which of the listed
types of safety valves is shown in the illustration? Illustration SG-
Pressure-loaded
type
Nozzle reaction
type
Huddling chamber
type
Jet flow type
C
A boiler safety
valve must be capable of __________.
closing with a
chattering motion to free scale deposits from the seats
remaining open
until all pressure in the steam drum is relieved
remaining open
until a preset pressure drop occurs
opening gradually
above a designated pressure
C
The primary operational
difference between a huddling chamber type safety valve and a nozzle reaction
type safety valve is the __________.
manner in which
steam pressure causes initial valve opening
difference in
valve relieving capacities
principle by which
blow down is accomplished
manner in which
lifting pressure is adjusted
A
The popping pressure
of the safety valve, shown in the illustration, is controlled by the __________.
Illustration SG-
amount of spring
compression
feather guide
retaining ring
adjusting ring
position
seat bushing adjustment
A
A boiler accumulation
test is used to measure the __________.
total relieving
capacity of the boiler safety valves
steam generating
capacity of the boiler
blow down pressure
of the boiler
lifting pressure
of the boiler safety valves
B
Proper bracing
and support of the boiler safety valve escape piping is necessary to __________.
prevent scale
from lodging on the valve seat
prevent stressing
of the safety valves
allow for back
pressure formation in the line
prevent condensate
from accumulating in lines
B
On a boiler equipped
with pilot actuated safety valves, which of the valves listed will be actuated
first?
Drum safety valve
Pilot actuated
safety valve for the superheater safety valve
Superheater safety
valve
Pilot actuated
safety valve for the drum safety valve
D
The boiler shown
in the illustration, arrow "O" indicates the __________. Illustration
SG-
main generating
tubes
superheater tubes
screen tubes
soot blower elements
A
The purpose of
the cam-actuated steam valve used in a boiler soot blower system is to __________.
prevent steam
from entering the soot blower when the element holes are directed toward
the refractory
rotate the element
through a predetermined blowing arc
automatically
secure steam to the blower head any time the element stops turning
automatically
blow the elements in the proper sequence
D
The purpose of
the pressure control disk installed in the multi-nozzle soot blower, as
shown in the illustration, is to __________. Illustration SG-
control the pressure
exerted on the valve spring retainer
control the pressure
exerted on the steam valve disk when the cam secures the steam supply
increase the pressure
in the steam supply line for proper soot blower operation
reduce the steam
supply pressure to the soot blower element
D
The glass used
in a flat-type boiler water gage is protected from the hot steam and water
by a/an __________.
asbestos gasket
copper insulator
felt cushion
mica shield
D
Bi-color water
level indicators, connected directly to the boiler drum, operate on the
principle of __________.
different chemical
properties of steam and water
special insoluble
indicating fluids
different densities
which result from the comparison of the varying steam pressure in the drum
different refractive
properties of steam and water
D
The items labeled "D"
and "M" as indicated on the illustration are commonly called __________.
Illustration SG-
cork gaskets
glass inserts
face plates
mica sheets
A
In a boiler water
gage glass, a ball check valve is installed on the __________.
bottom connection
only
top and bottom
connection
top connection
only
drain valve
C
The purpose of
the mica used in a boiler water gage glass assembly is to prevent __________.
light refraction
in the glass
leakage from the
glass
etching of the
glass
overheating of
the glass
A
The main steam
stop valve on a "D" type marine boiler is located at the __________.
superheater outlet
desuperheater
outlet
desuperheater
inlet
superheater inlet
C
A secondary function
of the refractory installed in a marine boiler is to __________.
support the boiler
casing
support the burner
distance piece
direct the flow
of combustion gases
maintain air flow
through the burner diffuser
A
Boiler refractories
previously baked out and fired are most sensitive to __________.
rapid cooling
sustained high
furnace temperature
radiant heat of
the burner
rapid heating
B
An advantage of
using boiler furnace studded water wall tubes packed with refractory is
that __________.
thinner tubes
can be used
the use of dense
firebricks is not required
thicker tubes
are required
lower quality
steel can be used
C
The useful life
of furnace refractory is affected most by __________.
the quality of
the fuel being burned
improper treatment
of boiler water
large and rapid
changes in furnace temperature
high steady steaming
boiler loads
B
A corbel is used
in a boiler furnace to __________.
direct the flow
of gases
protect the expansion
joints
reduce gas turbulence
contain the furnace
heat
A
Which of the listed
refractory materials is capable of providing structural stability?
Firebrick
Insulating brick
Chrome castable
Insulating block
C
According to the
illustration of a typical boiler furnace rear wall, which item number would
best represent "standard fire brick"? Illustration SG-
1
2
3
7
B
When heated, brickwork
in a boiler is kept from buckling by the installation of __________.
sliding saddles
expansion joints
insulating bricks
insulating blocks
A
According to the
illustration of a typical boiler furnace rear wall, which item number would
best represent "insulating brick"? Illustration SG-
1
2
3
7
D
Which of the following
statements represents the function of insulating brick?
Acts as a gas-side
layer at high temperature areas in D-type boilers.
Provides structural
stability.
Provides the first
layer at the inside of inner casing.
Acts as backup
insulation behind firebrick, plastic refractory, or castable refractory.
B
Which of the following
statements represents the advantage of using a small diameter boiler tube
over a larger diameter tube?
Small diameter
tubes reduce the heating surface area.
Small diameter
tubes reduce gas turbulence in the tube banks.
Small diameter
tubes provide for greater heat transfer rates.
Small diameter
tubes are less affected by the insulating properties of soot.
A
The advantage
of installing waterwall tubes in a boiler furnace is to __________.
permit higher
combustion rates
increase heat
transfer to the mud drum
decrease the flow
of gases through the furnace
increase the flow
of gases through the furnace
B
The component
lettered "J" shown in the illustration serves as a __________.
Illustration SG-
screen tube header
side water wall
header
support beam
water drum
A
The boiler shown
in the illustration has its screen tubes connecting the steam drum and the
component labeled __________. Illustration SG-
I
F
G
D
C
In most marine
boilers, the primary reason the first few rows of generating tubes, called
screen or furnace row tubes, are made larger in diameter than the rest of
the generating tubes is because __________.
their main function
is to retard combustion gas flow for maximum heat transfer rates
they must screen
the superheater from the direct radiant heat of the burners
they require more
water flow since they are exposed to the greatest heat
they must act
as downcomers to ensure proper circulation
C
In a D-type boiler,
which of the tubes listed would be located in the generating tube bank?
Waterwalls
Recirculating
tubes
Superheater support
tubes
Downcomer tubes
A
Which of the tube
types listed can be considered to serve as downcomers at low firing rates,
and as generating tubes at high firing rates on some boilers?
Superheater support
tubes
Water screen tubes
Water wall tubes
Riser tubes
D
In the boiler
shown in the illustration, the arrow "E" indicates a __________.
Illustration SG-
support tube
recirculating
tube
water wall tube
downcomer
B
The device shown
in the illustration is a/an __________. Illustration SG-
air ejector
desuperheater
deaerator
eductor
D
Desuperheated
steam can be found at the __________.
high-pressure
turbine steam chest
main steam stop
generator steam
stop
spray attemperator
outlet
C
Which of the following
locations could desuperheated steam be considered to occur?
Spray attemperator
Main engine extractions
Both "A"
and "B"
Neither "A"
nor "B"
D
The primary purpose
of a control desuperheater installed in the steam drum of a boiler is to
__________.
regulate the temperature
of superheated steam by adding moisture
assure a constant
volume of steam flow through the entire superheater under all load conditions
regulate saturated
steam temperature through the desuperheater
regulate the superheater
outlet temperature by cooling a portion of the superheated steam
C
That portion of
the steam drum, containing a manhole for internal access to the drum, for
the purpose of cleaning, inspecting, and carrying out repairs, is called
the __________.
wrapper sheet
tube sheet
drumhead
end plate
B
Which of the following
statements concerning boiler steam drum surface blow piping is correct?
The centerline
of the pipe is normally situated at a distance from the bottom of the steam
drum equal to approximately one-fourth the diameter of the drum.
Usually the surface
blow pipe is perforated with holes along its top surface; however, when
a scum pan is also employed, the holes are located along the bottom of the
pipe surface.
To ensure adequate
blow down, the aggregate cross-sectional area of these perforated holes
must be equal to approximately twice the cross-sectional area of the pipe.
All of the above.
D
The purpose of
the boiler drum air cock is to __________.
admit air when
the boiler is being emptied
permit escape
of air when the boiler is being filled
permit escape
of air when steam is forming in the drum after lighting off
All of the above.
C
Steam baffles
are used in the steam drum of a water-tube boiler to __________.
extend the internal
feed pipe
remove boiler
water dirt deposits
reduce the possibility
of carryover
support the drum
safety valve nozzles
B
The boiler wrapper
sheet, shown in the illustration, is indicated by arrow __________. Illustration
SG-
A
B
H
I
D
The main purpose
of the boiler steam drum component shown in the illustration is to __________.
Illustration SG-
reduce vibration
reduce the possibility
of priming
permit expansion
during pressure surges
prevent thermal
shock
D
Where is the 'dry
pipe' located in a boiler?
At the superheater
outlet
Behind the superheater
screen tubes
Below the generation
tube bank
In the top of
the steam drum
A
Which of the following
statements represents one operational characteristic of a cyclone steam
separator?
Unit imparts a
rotational motion to the steam and water mixture.
Steam is forced
to the outer side of the separator by centrifugal force.
Unit reduces the
circulation of the steam and water mixture in the boiler.
Water is forced
upward by centrifugal force.
C
A boiler internal
feed pipe is perforated to __________.
reduce the weight
of the steam drum internals
create a slight
turbulence in the steam drum
distribute water
evenly throughout the steam drum
provide positive
flow to the downcomers
B
Which of the devices
listed is indicated by arrow "H" shown in the illustration? Illustration
SG-
Overdeck superheater
Economizer
Air heater
Steam soot blowers
B
Boiler fuel savings
gained by the use of an economizer can amount to __________.
one-half percent
for each 15°F rise in feed water temperature
one percent for
each 10°F rise in feed water temperature
three percent
for each 5°F rise in feed water temperature
three percent
for each 20°F rise in feed water temperature
B
Which of the conditions
listed could cause steam formation in the economizer?
Soot buildup on
the gill rings.
Sudden large increase
in the firing rate.
Excessive water
flow rates.
An open main feed
pump recirculating line.
A
The boiler economizer
provides additional heat to the __________.
feed water entering
the boiler
steam leaving
the superheater
fuel oil entering
the furnace
air supply entering
the furnace
C
A check valve
is located between the economizer and the steam drum to __________.
assure a positive
feed water flow through the economizer
prevent the feed
pump from becoming vapor bound
prevent steam
and water flow reversal from the drum should an economizer casualty occur
assure a positive
feed water flow to the steam drum
B
The minimum feedwater
inlet temperature to a boiler economizer is determined by the __________.
superheater outlet
temperature
dew point temperature
of the stack gas
surface area of
the third stage heater
radiant heat transfer
in the furnace
D
The turbo-generator
steam stop is located between the superheater outlet and the main steam
stop valve to __________.
provide for easier
access
provide higher
quality steam for the turbo-generators
provide a flow
of cooling steam through the control desuperheater
allow the use
of superheated steam in the turbo-generator without pressurizing the larger
main steam line
A
The main steam
stop bypass valve is used to __________.
gradually increase
the pressure and temperature of the main steam piping when warming up
supply auxiliary
steam when the main steam stop is closed
isolate the main
steam stop for repairs while steaming
cross-connect
two steaming boilers
D
Scavenging air
is supplied to steam sootblower elements to __________.
prevent buildup
of soot on the element
provide cooling
air when soot blower elements are rotating through blowing arcs
prevent overheating
of adjacent tubing
prevent back up
of combustion gases into soot blower heads
D
In a boiler equipped
with a convection type superheater, the superheater tubes are located __________.
between the economizer
and generating tubes
between the downtake
nipple and circulator tube
in the path of
the radiant heat of combustion
in a position
screened from the furnace
D
The boiler superheater
shown in the illustration is a/an __________. Illustration SG-
horizontal U-type
overdeck convection-type
overdeck integral-type
vertical U-type
C
Which of the devices
listed is shown in the boiler illustration? Illustration SG-
Separately fired
superheater
Regenerative air
heater
Integral or interdeck
superheater
Retractable soot
blower
B
Boiler superheaters
are designed to __________.
raise the latent
heat of the steam
raise the sensible
heat of the steam
increase the overall
mechanical efficiency of the plant
provide continuous
steam flow to the control desuperheater
B
Which of the types
of superheaters listed has the flattest superheat temperature curve?
Convection
Radiant-convection
Radiant
Conduction-convection
A
Where is the superheater
located in the boiler shown in the illustration? Illustration SG-
G
H
I
J
A
In a regenerative
air heater, air is bypassed around the heater while __________.
operating at low
steaming rates
crossing over
forced draft fans
giving a surface
blow
blowing tubes
C
The bottom blow
valve on a water-tube boiler is usually attached to the __________.
steam and water
drum
external downcomers
boiler mud drum
floor tubes
A
When increasing
the firing rate of a boiler, which of the following should be carried out
FIRST?
Increasing the
forced draft air pressure.
Increasing the
fuel pressure.
Increasing the
feed water flow.
Decreasing the
steam pressure.
A
To safely decrease
the boiler firing rate, you should always reduce the fuel pressure __________.
before reducing
the forced draft pressure
after reducing
the forced draft pressure
by opening the
oil recirculating valve
by opening the
fuel pump relief valve
B
Which of the following
items should be checked each time the firing rate or forced draft pressure
is adjusted?
Atomizing steam
pressure
Smoke periscope
Fuel oil suction
pressure
Fuel oil heater
inlet temperature
D
As the percentage
of CO2 in the stack gas decreases, you can assume that __________.
the fuel to air
ratio is increasing
fuel is being
burned with increasing economy
you are approaching
secondary combustion
excess air is
increasing
D
One factor for
determining the minimum feedwater inlet temperature to a boiler economizer
is the __________.
desuperheater
outlet temperature
temperature of
steam bled off the LP turbine
superheater inlet
temperature
dew point temperature
of the stack gases
B
When answering
a full astern bell from half ahead, the superheater outlet temperature on
a single furnace boiler will __________.
remain the same
decrease due to
the increase steam volume used
increase sharply
with the increased firing rate
decrease momentarily
and then increase proportionately with load demand
B
If there is a
sudden drop in the outlet temperature of an uncontrolled superheater, you
should __________.
increase the firing
rate
check for high
water level in the drum
bypass the air
heater
reduce the forced
draft fan speed
D
Which of the valves
listed should be closed before lighting off a boiler?
Superheater vent
valve
Superheater drain
valve
Air cock valve
Economizer drain
valve
A
Which of the following
precautions should be taken prior to lighting off a boiler?
Purge the furnace
of combustible gases.
Bottom blow the
mud drum.
Secure the main
steam line drains.
Close the air
register.
A
Many steam plants
are designed so that diesel oil can be provided to the burners when __________.
lighting off a
cold ship
heavy smoking
persists
overload capacity
is required
a heavy fuel must
be blended
A
Steam assist fuel
atomizers are converted to straight mechanical atomizers in order to __________.
cold start a boiler
with diesel oil
raise steam on
the idle boiler
meet minimum boiler
steam demands
provide the best
fuel economy
D
The superheater
vents should always be open when __________.
blowing down the
boiler
the water level
is lower than normal
blowing tubes
lighting off the
boiler
C
Why should the
fuel oil be recirculated before lighting off a cold boiler?
To allow the fuel
strainers to thoroughly clean the fuel.
To allow fuel
pressure to buildup gradually.
To heat the fuel
enough for proper atomization.
To ensure that
all water is removed from the fuel.
A
Prior to lighting
a burner in a cold boiler, you should __________.
thoroughly purge
the furnace
open the surface
blow valve
blow down the
mud drum
close the superheater
vent
D
If a boiler is
brought on the line with its steam pressure much higher than that of the
boiler already on the line, there is danger of __________.
low water
an overloaded
superheater
thermal shock
priming and carryover
B
While raising
steam on a cold boiler, the air cock is to be closed after __________.
the economizer
drain is closed
steam has formed
and all air is vented
the boiler is
cut in on the line
all burners have
been lit and firing normally
A
When raising steam
on an idle boiler and the steam pressure has risen to about 5 pounds more
than the pressure of the boiler already on the line, you can __________.
put the boiler
on the line
close the superheater
vent
increase the boiler
firing rate
close the air
cock
B
The time taken
to raise steam on a cold boiler should always be.
not less than
a full 24 hours
the time specified
by the boiler manufacturer
not more than
1 full hour
as short as possible
to avoid excessive thermal expansion
A
When preparing
to cut a boiler in on the line, you determine that the steam pressure of
the incoming boiler is about 5 psig above line pressure. Which of the following
steps should you take next?
Open the desuperheated
steam stop.
Test the hand
relieving gear.
Open the superheater
vent.
Light off additional
burners.
A
After steam has
been raised and a boiler is being placed on the line, the superheater vent
can be closed when __________.
the boiler is
supplying auxiliary steam
the boiler steam
stops have been warmed up
main and auxiliary
steam line drains are opened
boiler pressure
is 5 psi above line pressure
D
When raising steam
on a boiler, the superheater drains should __________.
be closed until
just before line pressure is reached, and then given a short blow period
be opened to remove
condensate, and then closed when the first burner is lit
be closed until
after the air cock is closed, and then opened until the boiler is placed
on line
remain open or
partially open until steam blows through the lines, and then the valves
should be closed
D
When raising steam
on a cold boiler under normal conditions, you should always __________.
use a large orifice
burner sprayer plate to start
take 24 hours
to raise steam
raise steam within
one hour or less
use a small orifice
burner sprayer plate to start
D
Which of the following
statements about boilers is correct?
The water level
in a properly operated boiler will not shrink or swell.
No boiler will
continue to generate steam after the fires are secured.
Loss of water
will not harm a boiler if the water level can be restored.
A hot boiler will
continue to generate steam after the fires are secured.
B
When a boiler
has been secured and is being initially cooled, the water level showing
in the steam drum gage glass should be __________.
allowed to drop
naturally
maintained at
the normal level
allowed to go
out of sight
maintained at
a full glass
D
After a boiler
has been taken off the line and is cooling, the air cock is opened to __________.
purge all air
from the steam drum
guard against
entrapped gas pockets in the superheater
allow even cooling
of the steam drum
prevent the formation
of a vacuum within the boiler
A
Which of the valves
listed should be closed before lighting off a boiler?
Economizer drain
valve
Air cock valve
Superheater vent
valve
Superheater drain
valve
B
If a boiler is
brought on the line with its steam pressure much higher than that of the
boiler already on the line, there is danger of __________.
low water
priming and carryover
an overloaded
superheater
thermal shock
D
Which of the following
is the best reason for opening the air cock when draining a water-tube boiler?
Water flows out
of the boiler too rapidly with the air cock closed.
Air mixed with
the water will create a cleansing effect in the tubes.
Air coming into
the boiler will help dry out the boiler's surface.
With the air cock
open, the boiler drains without producing a vacuum.
A
A boiler is to
be secured in port. After the burners have been secured, the forced draft
fan and air registers should be secured __________.
after any oil
on the furnace floor has been burned off and cleared of combustion gases
after at least
1 hour has elapsed, after carrying out these securing procedures
after 30 minutes
has elapsed, after carrying out these procedures
immediately after
carrying out the former procedures
C
Which of the actions
listed should be carried out immediately after securing the fires in one
boiler of a two boiler ship?
Open the air registers
wide to cool the furnace.
Secure the main
feed pump.
Relieve all fuel
oil service pressure to that boiler.
Drain and refill
the boiler with cold water.
C
Before blowing
tubes in a boiler equipped with steam soot blowers, you should __________.
decrease the boiler
water level
lower the boiler
steam pressure
increase the boiler
water level
reduce the forced
draft fan speed
D
Before using a
boiler compressed air soot blower system, you should __________.
decrease the forced
draft fan speed
lower the water
level
reduce the boiler
pressure
drain the soot
blower pneumatic operating lines
D
To avoid acid
corrosion of the economizer tubes when blowing tubes.
lower water level
raise boiler pressure
lower boiler pressure
drain the soot
blowers headers
D
After routine
blowing of tubes at sea, there should be a decrease in the __________.
CO2 in the stack
gas
fuel oil temperature
excess air required
for complete combustion
stack temperature
B
When cleaning
the waterside of boiler tubes with a powered rotary brush, the brush should
be kept in motion to __________.
reduce tube pitting
avoid internal
tube damage
reduce wear to
brush bristles
prevent it from
seizing
A
If while filling
the boiler a newly installed gasket on a water-tube hand hole plate weeps,
you should __________.
center and tighten
with correct size wrench
coat the gasket
with graphite
use a double gasket
retighten the
stud nut with an air wrench
D
When a propulsion
boiler is removed from service for an extended period, why should the firesides
be thoroughly dried after water washing?
Prevent flarebacks
on lighting off.
Reduce the possibility
of thermal spalling.
Prevent cracking
of the brickwork.
Reduce the probability
of corrosion.
A
The correct method
of expanding a generating tube at the boiler drum tube sheet is to roll
__________.
to a depth greater
than the thickness of the drum tube sheet
slightly at the
tube end prior to welding the tube to the drum tube sheet
to a depth less
than the thickness of the drum tube sheet
heavily at the
tube end prior to welding the tube to the drum tube sheet
C
Which of the following
repairs should be made to a badly warped boiler tube?
Assure that the
warped tube does not touch adjacent tubes and then reroll it in the header.
Use a hydraulic
jack to cold bend the tube.
Replace the tube
with a spare, if available, or plug it.
Heat the tube
and use a soft mallet to straighten it.
B
A hole should
be made in the sagged tube occurring in a water-tube boiler, prior to plugging
the tube to prevent a __________.
crack failure
of the tube
pressure buildup
in the tube
complete sagging
failure of the tube
quick burnout
of the tube
D
To prevent a small
plastic refractory wall patch repair from falling into the furnace of a
D-type boiler, you should __________.
mix the plastic
with concrete prior to using
reinforce the
patch with fine mesh metal screen
attach anchor
bolts to the furnace casing
undercut the existing
brick around the area to be patched
D
When drying and
baking are impractical, or time is not available, which of the listed materials
could be used to repair both burner openings and gas baffles?
Baffle mix
Plastic chrome
ore
Plastic fire clay
High temperature
castable refractory
B
To make temporary
emergency repairs to brickwork in a boiler furnace, which of the materials
listed should be used?
Calcined diatomaceous
earth
Plastic refractory
Insulating block
Air setting mortar
A
Radial cracks
have developed in the castable refractory of the burner cones after the
first firing since the installation of new furnace front refractory. This
is an indication of __________.
relieved stresses
a need for castable
refractory patchwork
inadequate cone
angle
a need for plastic
firebrick patchwork
B
To assure a long
service life for boiler refractory materials after installation, the most
effective method is to __________.
maintain a high
furnace temperature at all times
avoid rapid temperature
changes and follow recommended operating procedures
properly secure
refractory with anchor bolts
patch refractory
with plastic chrome ore
C
When installing
new safety valve escape piping, precautions should include assuring that
__________.
the piping leads
directly to the bilge
the quick-closing
valve operates freely
no stress is transmitted
to the valve
bends or elbows
in the line do not exist
B
Improper water
washing of the water-tube boiler firesides can cause __________.
erosion of tubes
and drums
sulfuric acid
corrosion
decreased heat
transfer capabilities
loss of ductility
in boiler tubes
C
Which procedure
should be followed to dry out the fireside of a boiler after water washing?
Place trays of
silica gel in the furnace.
Use a wire reinforced
steam hose to put superheated steam in the furnace for 6 hours.
Alternately fire
one burner for 15 minute intervals during a 5 hour period.
Open the furnace
registers and run the forced draft fans for 3 hours.
D
The boiler water
gage glasses should be blown down __________.
when the boiler
water level changes in a steaming boiler
every 12 hours
of steady boiler steaming operation
twice each day
on the midnight and afternoon watches
when you are in
doubt about the water level
B
To properly blowdown
a boiler gage glass, you should __________.
blow through the
top (steam) connection first
blow through the
bottom (water) connection first
take up snugly
on upper and lower gage glass packing nuts prior to blowing down
never disconnect
the chains that connect the upper and lower cut out valves
C
In the absence
of the manufacturer's instructions, a good procedure in reassembling a high-pressure
boiler gage glass is to tighten the nuts in pairs and __________.
begin with the
end bolts and work toward the center
start at the top
and work down
begin with the
center bolts and work toward the ends
start at the bottom
and work up
D
You are standing
watch in the engine room of a steam vessel. You should blow down a gage
glass periodically to __________.
maintain the proper
water level in the steam drum
provide water
samples for the second assistant
test the feed
water stop-check valve
remove any sediment
that has accumulated
C
While your vessel
is underway at normal speed, a steam drum safety valve develops a significant
leak. Your first corrective action should be to __________.
secure the boiler
and blank off the valve flange
inspect the escape
piping for binding on the valve body
attempt to reseat
the valve using the hand releasing gear
secure the boiler
and check the valve spring compression
D
Lower than normal
steam pressure in an operating boiler may be caused by __________.
boiler water contamination
a sudden drop
in superheater outlet temperature
high feed water
temperature
a low water level
in the steam drum
A
Water in the fuel
supply to a steaming boiler can be detected by __________.
sputtering of
the fires
observation of
the fuel oil heater drains
panting of the
casing
dense white smoke
being observed in the periscope
A
Before an explosion
can occur in a boiler furnace, there must be an accumulation of unburned
fuel, sufficient air to form an explosive mixture, and a __________.
source of ignition
for the explosive mixture
space large enough
for the explosion to occur
high steam demand
on the boiler
ground in the
burner ignition electrode
A
What is the cause
of 'laning' in a boiler tube bank?
Excessive slag
accumulation on the tubes
Low fuel oil pressure
Reduced furnace
volume
Insufficient air
flow
B
Which color burner
flame would indicate too much excess air?
Yellowish orange
Incandescent white
Orange red
Bright red
A
Lower boiler efficiency
results from carrying too much excess air because __________.
it increases the
volume and temperature of the furnace gas leaving the stack
it decreases the
volatility of the fuel
the flame temperatures
are lower
it varies the
degree of deposits on heat absorbing surfaces
C
If the flue gas
oxygen content is too high, you should __________.
increase the forced
draft fan speed
increase the fuel
oil temperature
adjust the combustion
control system
adjust the fuel
oil service system
A
A higher than
normal stack gas temperature could indicate __________.
dirty firesides
or watersides
eroded water screen
tube walls
inner or outer
casing leakage
defects in burner
cone refractory
B
While the vessel
is rolling in heavy seas, the level in the boiler gage glass remains steady,
this is an indication that __________.
the water level
in the steam drum is too low
there is most
likely an obstruction in the lower valve
the steam drum
is adequately baffled
the gage glass
is functioning normally
B
Which of the following
actions, if any, should be taken if the water gage glass on a steaming boiler
breaks?
Reduce the firing
rate.
Close the gage
glass cutout valves.
Close in on the
feed stop-check valve.
No action is necessary
since checks in the cutout valves automatically seat to stop loss of steam
and water.
D
If the engineer
on watch has reason to doubt the accuracy of the water level shown in the
boiler gage glass, he should __________.
speed up the main
feed pump
open the auxiliary
feed line
start the standby
feed pump
blow down the
gage glass
C
An obstruction
in the top connection of a boiler gage glass will cause the __________.
gage glass to
overheat and break
gage glass to
be blown empty
water level to
rise slowly in the glass
water level to
remain constant in the glass
C
If the engineer
on watch has reason to doubt the accuracy of the water level showing in
the boiler gage glass, he should FIRST __________.
start the standby
feed pump
open the auxiliary
feed line
blow down the
gage glass
replace the gage
glass
D
Boiler tube failures
can result from __________.
mechanical stress
overheating
corrosion
All of the above.
A
Why are hard scale
deposits on the inside of boiler tubes most objectionable?
Poor heat transfer
due to hard scale deposits overheats tubes.
Flow of water
within the tube is restricted.
Hydroxyl ions
liberated by the scaling process form acid in the boiler water.
The metal of the
tube interior is eaten away by scale.
D
The MOST common
cause of heat blisters developing on boiler generating tubes is due to__________.
flame impingement
gas laning
insufficient water
circulation
waterside deposits
B
Oil or scale deposits
on boiler tube walls will cause __________.
decreased boiler
steam pressure
those tubes to
overheat
increased boiler
steam pressure
an explosion in
the boiler
C
If a boiler tube
bank baffle carries away, or burns through, there will be __________.
fireside burning
of boiler tubes
excessive gas
turbulence in the furnace
localized overheating
of the water drum
incomplete combustion
D
Excessive foaming
in a steaming boiler can cause damage to the __________.
internal feed
pipe
economizer
desuperheater
superheater
A
In a boiler equipped
with an automatic feed water regulator, erratic variations in the water
level could be caused by __________.
high solids content
and foaming in the drum
high feed water
temperature
ruptured feed
water control valve diaphragm
low feed water
temperature
C
Oil accumulation
in boiler water would __________.
increase the heat
transfer rate
practically eliminate
boiler sludge formation
cause foaming
and carryover from the boiler
prevent acid attack
on the boiler tubes
C
Damaging scale
can form on the interior of superheater tubes as a result of __________.
high superheater
outlet temperature
insufficient steam
flow through the superheater
boiler water carryover
leaks from the
desuperheater
D
Under otherwise
normal steaming conditions, an abnormally high temperature at the superheater
outlet of a single furnace boiler would indicate.
high steam demand
insufficient combustion
air
excessive steam
supply to fuel oil heaters
poor heat transfer
in feed water heaters
C
A heavy accumulation
of soot on the fireside of the superheater can cause a __________.
high superheater
outlet temperature because of gas laning
high superheater
outlet temperature because of reduced steam flow
low superheater
outlet temperature because of the insulating effect of soot
high superheater
inlet temperature because of decreased heat transfer
C
Insufficient combustion
air supply to the furnace would cause __________.
high feed water
consumption
the fires to sputter
low superheater
outlet temperature
high stack temperature
D
If a pressure
drop does not exist across the superheater in a steaming boiler __________.
the feed water
temperature is too low
this is a normal
condition
the drum safety
valve is about to lift ahead of the superheater safety
there is no steam
flow through the superheater
B
Which of the listed
conditions can cause high superheater outlet steam temperature in an automated
boiler?
Insufficient excess
air.
Operating with
a bypassed economizer.
Excessive heat
transfer in the control desuperheater.
High water level
in the steam drum.
B
Slag buildup on
boiler furnace refractory is undesirable because it causes __________.
fracturing of
the anchor bolts
peeling or spalling
of the brickwork
excessive cooling
of the brickwork
shrinking of the
brickwork
D
Which of the following
conditions is indicated by an external bulge or bowed area of the boiler
furnace wall?
The brickwork
has become slagged.
The insulation
block has become slagged.
The corbels have
failed.
The furnace brickwork
has collapsed in that area.
A
Which of the following
problems can occur when an excessive number of water screen tubes are plugged?
Superheater outlet
temperature will rise.
Steam pressure
leaving the drum will increase.
Superheater outlet
pressure will rise.
Steam temperature
in the drum will decrease.
A
Which of the conditions
listed occurs when glassy slag, formed by the burning of fuel oil contaminated
with salt water, melts and runs over the furnace wall?
Damage to the
furnace refractory.
Cracks through
the furnace floor.
Increased furnace
temperature.
Formation of a
protective coating.
C
Which of the following
would indicate a moderate leak in the desuperheater?
Lower than normal
fuel oil consumption
Higher than normal
fuel oil consumption
Lower than normal
auxiliary steam temperature
Higher than normal
auxiliary steam pressure
B
Which of the conditions
listed could cause a boiler economizer to leak?
Low feed water
pressure.
Water hammer.
High feed water
temperatures.
High stack gas
temperatures.
B
Which of the conditions
listed would indicate excessive soot buildup on the economizer?
Low air temperature
entering the boiler
High superheater
temperature
Lower than usual
air pressure in the furnace
High feed water
temperature entering the boiler
A
If a soot blower
element does not revolve freely, the most likely cause would be __________.
warpage of the
soot blower element
an improper blowing
arc cam setting
insufficient steam
pressure to the soot blower element
a seized blower
head bearing
C
A nozzle reaction
safety valve will lift at a pressure lower than required if the __________.
nozzle ring has
come adrift
adjusting ring
is set too low
spring compression
is insufficient
blow down is set
too low
C
If it should become
necessary to abandon a compartment because of the danger of a large steam
leak on a boiler, which of the following actions represents the best avenue
of escape?
Escape through
another compartment on a higher level.
Use fire room
elevator to an upper deck.
Escape through
another compartment on a lower level.
Escape by way
of a fire room ladder to the outer deck.
B
Which of the precautions
listed should be taken when gagging a boiler safety valve?
Tighten the gag
only with the special wrench supplied with the gag.
Tighten the gag
only finger tight to prevent damage to the valve stem, disc or seat.
Ensure that all
moving parts of the safety valve are free to move before installing the
gag.
Do not allow the
gag to contact the safety valve stem.
C
If a major flareback
occurs to a boiler, which of the following actions should be immediately
taken?
Secure all fire
room ventilation.
Secure the forced
draft fan.
Secure the fuel
to the burners.
Purge the fuel
oil system.
A
If the water level
in one boiler of a two boiler plant rapidly falls out of sight, which of
the following actions should be carried out FIRST?
Secure the fuel
oil to that boiler.
Secure the steam
stop to that boiler.
Blow down the
gage glass.
Raise the feed
pump pressure.
D
Which of the following
actions should be carried out if the boiler water level is falling due to
a tube failure?
Open the auxiliary
feed stop and check for extra feed.
Speed up the feed
pump to keep the water level up while firing the boiler.
Start the standby
feed pump and feed the boiler using two feed pumps.
Secure the fires
and try to maintain the water level.
A
Which action should
be taken if the water level in the boiler gage glass drops out of sight
and the burners fail to secure automatically?
Trip the master
solenoid.
Repair the feed
water regulator.
Increase the feed
pump speed.
Blow down the
gage glass.
C
After restoring
the normal water level in a boiler following a high-water casualty, you
should __________.
immediately drain
the economizer
immediately put
the boiler on the line
completely drain
the superheater
blow down the
water gage glass
A
Under EMERGENCY
operating conditions, the proper valve positions for controlling feedwater
to the boiler should be the __________.
auxiliary stop
valve fully open and the auxiliary stop-check valve used to regulate the
amount of flow
auxiliary stop
and stop-check valves fully open and the feed pump speed used to regulate
the amount of flow
auxiliary stop-check
valve fully open and the auxiliary stop valve used to regulate the amount
of flow
auxiliary stop-check
valve fully open and the auxiliary stop valve regulated by the feed water
regulator
D
In the event of
a failure of the pneumatic control system, a multi-element feedwater regulator
is designed to operate as a __________.
constant-volume
feed water regulator
constant-pressure
regulator
thermo-hydraulic
feed water regulator
manually controlled
feed water regulator
A
One boiler of
a two boiler plant has ruptured a tube and the water cannot be maintained
in sight in the gage glass. After securing the fires, your next action should
be to __________.
secure the feed
water supply to the boiler
close the main
steam stop
secure the forced
draft fans
stop the fuel
oil service pump
C
The boiler wrapper
sheet, shown in the illustration, is indicated by arrow __________. Illustration
SG-
A
H
B
I
A
In what section
of a boiler would you find a steam quality of 90%?
Steam drum
Desuperheater
outlet
Superheater outlet
Last pass of the
superheater
A
Steam baffles
are used in the steam drum of a water-tube boiler to __________.
reduce the possibility
of carryover
support the drum
safety valve nozzles
remove boiler
water dirt deposits
extend the internal
feed pipe
A
The internal feed
pipe in a D-type marine boiler __________.
distributes feed
water evenly throughout the steam drum
is drilled with
holes to provide even distribution of boiler feed water chemicals
is located well
above the normal steam drum water level to assist in deaeration of feed
water
guides the feed
water toward the downcomer tubes
C
Which of the following
statements represents the purpose of boiler sliding feet?
To ensure an airtight
seal between the boiler inner and outer casings.
o
To compensate
for deflection of the hull in way of the boiler supports.
To accommodate
the changing length of the water drum as it expands or contracts with temperature
changes.
To allow for unequal
expansion between the wrapper and tube sheets.
D
Which area shown
in the illustration will offer the most resistance to heat transfer from
the fireside to the waterside of a boiler tube? Illustration SG-
D
E
C
B
C
Under what operating
conditions may water wall header drains be used for blow down?
When it is necessary
for rapid drainage of the boiler.
During periods
of carryover in the steam drum.
Only if the fires
are secured and no steam is being generated.
When the water
level is out of sight in the gage glass.
C
In the boiler
shown in the illustration, the arrow "E" indicates a __________.
Illustration SG-
support tube
recirculating
tube
downcomer
water wall tube
A
One advantage
of installing water wall tubes in a boiler furnace is to __________.
decrease refractory
maintenance
reduce combustion
rates
increase furnace
size
reduce furnace
temperature
A
In most marine
boilers, the primary reason the first few rows of generating tubes, called
screen or furnace row tubes, are made larger in diameter than the rest of
the generating tubes is because __________.
they require more
water flow since they are exposed to the greatest heat
they must screen
the superheater from the direct radiant heat of the burners
they must act
as downcomers to ensure proper circulation
their main function
is to retard combustion gas flow for maximum heat transfer rates
D
The boiler superheater
shown in the illustration is a/an __________. Illustration SG-
overdeck convection-type
overdeck integral-type
horizontal U-type
vertical U-type
D
Where is the superheater
located in the boiler shown in the illustration? Illustration SG-
I
J
H
G
B
The purpose of
the division plates installed in boiler superheater headers is to __________.
limit the maximum
temperature rise of the superheater outlet to 15°F
ensure proper
steam flow, thus preventing 'short circuiting' of superheater loops
provide a means
of controlling steam passage in response to throttle demands
All of the above.
D
Which of the devices
listed is shown in the boiler illustration? Illustration SG-
Regenerative air
heater
Separately fired
superheater
Retractable soot
blower
Integral or interdeck
superheater
A
The items labeled "D"
and "M" as indicated on the illustration are commonly called __________.
Illustration SG-
mica sheets
glass inserts
cork gaskets
face plates
B
The device shown
in the illustration is a/an __________. Illustration SG-
deaerator
desuperheater
eductor
air ejector
C
Desuperheated
steam can be found at the __________.
main steam stop
generator steam
stop
spray attemperator
outlet
high pressure
turbine steam chest
C
Which of the following
locations could desuperheated steam be considered to occur?
Spray attemperator
Main engine extractions
Both "A"
and "B"
Neither "A"
nor "B"
A
The primary purpose
of a control desuperheater installed in the steam drum of a boiler is to
__________.
regulate the superheater
outlet temperature by cooling a portion of the superheated steam
regulate saturated
steam temperature through the desuperheater
regulate the temperature
of superheated steam by adding moisture
assure a constant
volume of steam flow through the entire superheater under all load conditions
A
Which of the devices
listed is indicated by arrow "H" shown in the illustration? Illustration
SG-
Economizer
Steam soot blowers
Overdeck superheater
Air heater
B
The minimum feedwater
inlet temperature to a boiler economizer is determined by the __________.
radiant heat transfer
in the furnace
dew point temperature
of the stack gas
superheater outlet
temperature
surface area of
the third stage heater
C
Boiler fuel savings
gained by the use of an economizer can amount to __________.
one half percent
for each 15°F rise in feed water temperature
three percent
for each 5°F rise in feed water temperature
one percent for
each 10°F rise in feed water temperature
three percent
for each 20°F rise in feed water temperature
D
Which of the conditions
listed could cause steam formation in the economizer?
Soot buildup on
the gill rings.
An open main feed
pump recirculating line.
Excessive water
flow rates.
Sudden large increase
in the firing rate.
D
The boiler economizer
provides additional heat to the __________.
steam leaving
the superheater
air supply entering
the furnace
fuel oil entering
the furnace
feed water entering
the boiler
A
A check valve
is located between the economizer and the steam drum to __________.
prevent steam
and water flow reversal from the drum should an economizer casualty occur
assure a positive
feed water flow to the steam drum
prevent the feed
pump from becoming vapor bound
assure a positive
feed water flow through the economizer
B
One factor for
determining the minimum feedwater inlet temperature to a boiler economizer
is the __________.
superheater inlet
temperature
dew point temperature
of the stack gases
temperature of
steam bled off the LP turbine
desuperheater
outlet temperature
D
Which of the listed
refractory materials can be used in an area directly exposed to the highest
heat in the furnace?
Baffle mix
Insulating block
Insulating brick
Firebrick
A
In a regenerative
air heater, air is bypassed around the heater while __________.
operating at low
steaming rates
giving a surface
blow
blowing tubes
crossing over
forced draft fans
C
When heated, brickwork
in a boiler is kept from buckling by the installation of __________.
insulating bricks
insulating blocks
expansion joints
sliding saddles
A
Which of the listed
refractory materials is composed of wool fibers and clay binders?
Insulating cement
Castable fireclay
Chrome castable
ore
All of the above.
D
According to the
illustration of a typical boiler furnace rear wall, which item number would
best represent "insulating block"? Illustration SG-
3
1
2
7
A
Boiler refractory
firebrick is secured to the casing by __________.
slots in the brick
engaging anchor bolts
fast drying plastic
refractory mortar
high strength
tensile fasteners
studding on the
water wall tubes
D
Boiler refractory
previously baked out and fired is most sensitive to __________.
radiant heat of
the burner
rapid heating
sustained high
furnace temperature
rapid cooling
A
Which of the listed
types of safety valves is shown in the illustration? Illustration SG-
Huddling chamber
type
Pressure-loaded
type
Jet flow type
Nozzle reaction
type
C
On a boiler safety
valve, the blowdown adjusting ring is locked in place by a __________.
wire seal
locknut
set screw
cotter pin
A
What is the primary
operational difference between a nozzle reaction safety valve and a huddling
chamber safety valve?
The principle
by which blow down is accomplished.
The manner in
which lifting pressure is adjusted.
The difference
in valve relieving capacities.
The manner in
which steam pressure causes initial valve opening.
A
When excessive
static boiler pressure has resulted in the initial lift of the valve disc,
a huddling chamber safety valve will continue to lift open as a result of
___________,
steam pressure
acting on the enlarged area of projecting lip or ring
the resulting
reactive force created by the rapid expansion of escaping steam
an increase in
steam velocity through an adjustable orifice ring
steam pressure
transmitted through a pipe connected to the superheater outlet
A
Scavenging air
lines are connected to boiler stack periscopes to __________.
prevent stack
gases from contaminating the periscopes internal components
maintain a negative
pressure in the periscope line
keep the mirrors
from misaligning
keep the periscope
tubing from warping
D
Which type of
waterside deposits can normally be removed by chemically boiling out a boiler?
Sludge
High temperature
oxide
Corrosion deposits
Oil
D
Steam line water
hammer can be best prevented by __________.
always opening
steam valves rapidly
replacing all
90°Elbows with capped tees
keeping steam
temperature below the saturation point
keeping lines
drained and insulated
C
A water-tube boiler
can be laid up either wet or dry. If it is to be laid up wet, you should
__________.
drain and refill
the boiler when the pH goes above 6
drain and refill
the boiler each week
completely fill
the boiler with deaerated feed water and maintain a slight pressure
completely fill
the boiler with water, then blow down to steaming level
B
Which of the methods
listed would be most effective in repairing a steam cut on a seating surface
of a superheater handhole plate?
Filling the cut
with iron cement or plastic steel.
Filling the cut
by welding and then grinding it smooth.
Refacing the surface
and over torquing the handhole plate.
Grinding the seating
surface and installing an oversized gasket.
B
Which of the tools
listed is used to remove a boiler tube from a header?
Swaging tool
Backing out tool
Laminating tool
Expanding tool
A
When you are installing
a new furnace floor in an oil fired boiler, the clearance between the firebricks
should be large enough to __________.
allow for expansion
without subjecting the joint to flame penetration
facilitate rebricking
at required maintenance intervals
allow for installation
of plastic chrome ore after drying
allow for proper
filling with slag under normal operating conditions
A
Which of the listed
procedures is the most important factor to take into consideration when
making repairs to the refractory surrounding the burner openings?
Design refractory
cone angle must be maintained.
All cracks must
be completely filled.
Plastic firebrick
must be used.
Finished repair
surfaces must be smooth.
C
A furnace wall
in which there are open spaces around the brick as a result of firebrick
shrinkage, is __________.
spalled and must
be replaced
normal and need
only be cleaned
loose and should
be repaired
cracked and must
be patched
B
Which of the listed
refractory materials should be used for patching a burner front formed of
plastic, castable, or tile?
Air-setting mortar
Plastic fireclay
Chrome castable
insulation
Plastic chrome
insulation
D
After patching
refractory with plastic firebrick, holes are poked in the patch on 1 1/2
inch centers in order to __________.
allow for expansion
prevent slag buildup
prevent spalling
vent escaping
moisture
C
To assure a long
service life for boiler refractory materials after installation, the most
effective method is to __________.
patch refractory
with plastic chrome ore
properly secure
refractory with anchor bolts
avoid rapid temperature
changes and follow recommended operating procedures
maintain a high
furnace temperature at all times
A
When installed,
the economizer relief valve should always be set __________.
50 pounds higher
than the drum safety valve plus the water pressure drop through the economizer
50 pounds higher
than the superheater safety valve plus the water pressure drop through the
economizer
at the same pressure
as the superheater safety valve
at the same pressure
as the drum safety valve
D
When water washing
a boiler, the proper sequence for washing the sections should be the __________.
generating tubes,
superheater, and then economizer
screen tubes,
generating tubes, and then superheater
superheater, economizer,
and then generating tubes
economizer, superheater,
generating, and then screen tubes
D
Which of the listed
mediums should be used when water washing a boiler?
Cold freshwater
Cold saltwater
Heated saltwater
Heated freshwater
B
According to the
data given in the illustration, which of the following would be the physical
state of the fluid at a gage vacuum of 25.03 inches Hg, and 126.08 degrees
Fahrenheit? Illustration SG-
Superheated vapor.
Sub cooled liquid.
Mixture of saturated
liquid and vapor.
Saturated liquid.
B
If the saturation
pressure of water is increased, the relative values shown on the illustrated
graph of SG- will change. According to pertinent information found in
the steam tables of SG-, this will result in __________. Illustration
SG- Illustration SG-
no change to the
length of line 4
a decrease the
length of line 4
no change in the
height of line 4
a decrease in
the height of line 4
B
Which of the following
statements is true concerning the information tabulated in the table? Illustration
SG-
At 185.3 psig
(.4 kPa), the saturation temperature of a mixture of water and steam
is 377.51°F (192°C).
When one pound
of water changes to one pound of steam at 200 psia (.8 kPa), its volume
increases 124.41 times.
If one pound of
steam at 250 psia (.5 kPa) condenses to one pound of water it will give
up 843 BTU's (889.4 kJ) while changing state.
All of the above.
D
According to the
data given in illustration, which of the following would be the physical
state of the fluid at a gage vacuum of 28.09 inches Hg, and 117.99 degrees
Fahrenheit? Illustration SG-
Mixture of saturated
liquid and vapor.
Sub cooled liquid.
Saturated liquid.
Superheated vapor.
A
If a boiler generates
saturated steam at 125.3 psig, how much heat is required to change the water
into steam if the feed water temperature is 240°F? Illustration SG-
983.4 Btu/lb
582.7 Btu/lb
30.5 Btu/lb
116.5 Btu/lb
C
What physical
changes will occur to the steam within a boiler that has been properly bottled
up when additional heat is applied?
The pressure will
increase and the volume will remain constant.
The steam pressure
and it specific volume will remain constant.
The pressure will
increase and the specific volume will decrease.
The pressure will
remain constant and the specific volume will increase.
C
The major heat
loss in an oil fired boiler is the heat __________.
required to change
water into steam
passing through
the boiler casing
going up the stack
used in the economizer
and air heater
A
A lower than normal
boiler stack gas temperature usually indicates __________.
incomplete combustion
dirty watersides
dirty firesides
fuel high sulfur
content
D
A high carbon
monoxide content in the flue gases of a boiler indicates __________.
complete combustion
a high carbon
content fuel
too much excess
air
incomplete combustion
A
When the rate
of heat transfer through tube walls is so reduced that the metal becomes
overheated, which of the following conditions will result in the boiler?
Fireside burning
Fireside thinning
Steam gouging
Steam binding
A
Cratering and
water tracking in boiler tubes is caused by __________.
water trapped
between tubes and refractory
burning a fuel
with a high vanadium content
soot corrosion
baked on slag
deposits
D
The formation
of a pit in the surface of a boiler tube is most likely to occur when __________.
dissolved minerals
are present
waterside deposits
are present
sludge is present
the tube metal
acts as an anode
C
In a water-tube
boiler, waterside scale formation is caused by __________.
sodium hydroxide
sodium phosphate
calcium sulfate
magnesium phosphate
B
Blisters developing
on boiler tubes can be caused by __________.
hot feed water
waterside scale
deposits
cold feed water
air in the feed
water
A
Waterside abrasion
of boiler tubes can be caused by __________.
mechanical tube
cleaning
oxygen corrosion
improper bends
in the tubes
entrained impurities
in the boiler water
C
Fireside burning
of boiler tubes is usually the direct result of __________.
gas laning in
tube banks
oxygen corrosion
of metallic surfaces
overheating due
to poor heat transfer
high furnace temperatures
D
Boiler tube failures
can result from __________.
corrosion
overheating
mechanical stress
All of the above.
B
Warping of superheater
screen tubes can be caused by __________.
high superheater
temperatures
sudden cooling
of tubes after being overheated
high furnace temperatures
installing baffles
of excessive length
C
An excessively
high superheater temperature could be the result of __________.
soot accumulation
on the superheater
high feed water
temperature
excessive air
excessive steam
demand
D
When operating
under constant load, the superheated steam temperature may rise above normal
if the __________.
excess air is
too low
feed water temperature
is too high
boiler is priming
feed water temperature
is too low
A
Under normal operating
conditions, a drop in the steam temperature leaving an uncontrolled interdeck
superheater could be caused by a __________.
decrease in combustion
gas velocity through the superheater
badly fouled economizer
decrease in steam
velocity through the superheater
drop in the feed
water temperature
C
Insufficient combustion
air supply to the furnace would cause __________.
high feed water
consumption
high stack temperature
low superheater
outlet temperature
the fires to sputter
A
Dirty generating
tube surfaces may cause higher than normal superheater outlet temperatures
because __________.
the boiler must
be over fired to maintain the required rate of steam generation
the screen tubes
absorb excessive heat and transfer the increased temperature to the superheater
the temperature
of the gas leaving the generating banks will be lower than normal
gas laning will
result causing overheating of the superheater
B
Which of the following
would indicate a moderate leak in the desuperheater?
Higher than normal
auxiliary steam pressure
Lower than normal
auxiliary steam temperature
Higher than normal
fuel oil consumption
Lower than normal
fuel oil consumption
C
Which of the conditions
listed could cause a boiler economizer to leak?
High stack gas
temperatures.
High feed water
temperatures.
Water hammer.
Low feed water
pressure.
B
Which of the conditions
listed would indicate excessive soot buildup on the economizer?
High feed water
temperature entering the boiler
High superheater
temperature
Lower than usual
air pressure in the furnace
Low air temperature
entering the boiler
C
Slag buildup on
boiler furnace refractory is undesirable because it causes __________.
shrinking of the
brickwork
excessive cooling
of the brickwork
peeling or spalling
of the brickwork
fracturing of
the anchor bolts
A
Which of the following
conditions is indicated by an external bulge or bowed area of the boiler
furnace wall?
The furnace brickwork
has collapsed in that area.
The insulation
block has become slagged.
The corbels have
failed.
The brickwork
has become slagged.
D
Which of the following
problems can occur when an excessive number of water screen tubes are plugged?
Steam temperature
in the drum will decrease.
Superheater outlet
pressure will rise.
Steam pressure
leaving the drum will increase.
Superheater outlet
temperature will rise.
D
Which of the conditions
listed occurs when glassy slag, formed by the burning of fuel oil contaminated
with salt water, melts and runs over the furnace wall?
Formation of a
protective coating.
Cracks through
the furnace floor.
Increased furnace
temperature.
Damage to the
furnace refractory.
A
Excessive foaming
in a steaming boiler can cause damage to the __________.
superheater
internal feed
pipe
desuperheater
economizer
A
In a boiler equipped
with an automatic feed water regulator, erratic variations in the water
level could be caused by __________.
high solids content
and foaming in the drum
ruptured feed
water control valve diaphragm
high feed water
temperature
low feed water
temperature
C
Rapid fluctuation
in the superheater temperature of a steady steaming boiler indicates __________.
improper positioning
of superheater fires
leaky superheater
tubes
moisture carryover
leaky desuperheater
tubes
A
Oil accumulation
in boiler water would __________.
cause foaming
and carryover from the boiler
prevent acid attack
on the boiler tubes
practically eliminate
boiler sludge formation
increase the heat
transfer rate
C
High boiler water
level can cause carryover and __________.
warped screen
tubes
warped water wall
tubes
damage to the
superheater tubes
damage to the
economizer
A
Which of the precautions
listed should be taken when gagging a boiler safety valve?
Tighten the gag
only finger tight to prevent damage to the valve stem, disc or seat.
Tighten the gag
only with the special wrench supplied with the gag.
Do not allow the
gag to contact the safety valve stem.
Ensure that all
moving parts of the safety valve are free to move before installing the
gag.
C
Which of the listed
operating practices is considered as safe, and should be followed when opening
and inspecting the waterside of a boiler?
Ventilate the
waterside until completely dry.
Open the water
drum manhole before opening the steam drum manhole.
Wire all valves
closed that connect to other boilers.
Remove handhole
plate dogs with a slugging wrench.
D
If it should become
necessary to abandon a compartment because of the danger of a large steam
leak on a boiler, which of the following actions represents the best avenue
of escape?
Escape through
another compartment on a higher level.
Escape by way
of a fire room ladder to the outer deck.
Use fire room
elevator to an upper deck.
Escape through
another compartment on a lower level.
B
While underway,
the boiler water level in a steaming boiler begins dropping rapidly and
cannot be kept at the normal level by standard practices. The engineer's
next action should be to __________.
blow down the
gage glass to find the true water level
secure the fires
and then secure the main feed stop/check valve to the boiler
continue to speed
up the feed pump to raise the water level
secure the steam
stop and then secure the fires
B
Which of the casualties
listed is apt to occur immediately after a high water casualty?
Excessive steam
pressure
Water carryover
to the turbines
Excessive superheater
temperature
Massive tube failure
B
Which action should
be taken if the water level in the boiler gage glass drops out of sight
and the burners fail to secure automatically?
Repair the feed
water regulator.
Trip the master
solenoid.
Blow down the
gage glass.
Increase the feed
pump speed.
C
Which of the following
actions should be carried out if the boiler water level is falling due to
a tube failure?
Start the standby
feed pump and feed the boiler using two feed pumps.
Open the auxiliary
feed stop and check for extra feed.
Secure the fires
and try to maintain the water level.
Speed up the feed
pump to keep the water level up while firing the boiler.
D
If a major flareback
occurs to a boiler, which of the following actions should be immediately
taken?
Purge the fuel
oil system.
Secure all fire
room ventilation.
Secure the forced
draft fan.
Secure the fuel
to the burners.
A
Under EMERGENCY
operating conditions, the proper valve positions for controlling feedwater
to the boiler should be the __________.
auxiliary stop
valve fully open and the auxiliary stop-check valve used to regulate the
amount of flow
auxiliary stop
and stop-check valves fully open and the feed pump speed used to regulate
the amount of flow
auxiliary stop-check
valve fully open and the auxiliary stop valve regulated by the feed water
regulator
auxiliary stop-check
valve fully open and the auxiliary stop valve used to regulate the amount
of flow
A
In the event of
a failure of the pneumatic control system, a multi-element feedwater regulator
is designed to operate as a __________.
manually controlled
feed water regulator
constant-pressure
regulator
thermo-hydraulic
feed water regulator
constant-volume
feed water regulator
A
One boiler of
a two boiler plant has ruptured a tube and the water cannot be maintained
in sight in the gage glass. After securing the fires, your next action should
be to __________.
secure the feed
water supply to the boiler
close the main
steam stop
secure the forced
draft fans
stop the fuel
oil service pump
C
The phrase 'boiler
water column' as defined in the regulations, refers to the __________.
pressure gauge
reading in feet of water
pressure head
to the feed water pump suction
water level indicator
vertical water
leg
D
When two or more
boilers provide steam flow to a common main steam line, each boiler main
steam line shall be fitted with a main steam stop valve and a/an.
auxiliary steam
stop valve
gate valve
swing check valve
stop-check valve
B
When preparing
to hydrostatically test water-tube boilers, you should __________.
remove all inspection
plates and manhole covers as required by the marine inspector
fill the boiler
with water not less than 70°F (21.1°C), nor more than 160°F (71.1°C)
make arrangements
for simultaneously testing main and auxiliary steam stops with water and
steam pressure
have the boiler
warmed to a temperature not exceeding 100°F (37.8°C)
B
Which of the following
statements is true concerning boiler inspections?
At the first inspection
for certification after a water-tube boiler has been installed for ten years,
it shall be gauged by drilling to determine the actual extent of deterioration.
The marine inspector
may require any boiler to be drilled to determine its actual thickness any
time its safety is in doubt.
If the thickness
found as a result of gauging is less than original thickness, the boiler
must be condemned.
Any user of a
nondestructive testing device must demonstrate that results with an accuracy
of plus or minus one percent are consistently obtainable.
C
According to 46
CFR Part 61, which of the following statements is true concerning the inspection
of water-tube boilers?
Boiler mountings
attached to boiler nozzles must be opened and removed for examination every
8 years.
All mountings
shall be opened up and examined by a Coast Guard inspector at eight year
intervals after the initial inspection.
Boiler mountings
attached directly to the boiler plating by screwed studs and nuts shall
be removed and examined every 10 years.
All boiler mounting
studs or bolts shall be removed for examination by a Coast Guard inspector
every 4 years after initial inspection.
A
Which of the following
statements represents the Coast Guard Regulation regarding a boiler installation
in which the superheater outlet temperature exceeds 850°F?
Visible and audible
alarms indicating excessive superheat shall be provided.
A device, actuated
by inlet static pressure and designed to function by the bursting of a pressure
retaining disk, must be fitted at the outlet of the superheater.
All mountings,
fittings, valves, or other superheater attachments must be of malleable
cast iron.
Safety valves
are to be set at 110% of the highest setting of the safety valves on the
drum.
A
Which of the Coast
Guard publications listed contain the information regarding allowable repairs
to boilers installed on cargo vessels?
Marine Engineering
Regulations
Rules and Regulations
for Cargo and Miscellaneous Vessels
Modern Marine
Engineer's Manual
Manufacturer's
Instruction Manual
D
According to Coast
Guard Regulations (46 CFR), which of the following is classified as a boiler
mounting?
Main feed check
valve
Soot blower element
Escape piping
drain valve
Blow-off valve
B
Coast Guard Regulations
(46 CFR) state that main propulsion water-tube boilers are not required
to be fitted with a surface blow off valve if the design pressure is __________.
300 psig (
kPa) or over
350 psig (
kPa) or over
500 psig (
kPa) or over
550 psig (
kPa) or over
D
Coast Guard Regulations
(46 CFR Part 5 permit copper pipe to be used for steam service subjected
to a maximum pressure and temperature of.
350 psi and 460°F
350 psi and 406°F
250 psi and 460°F
250 psi and 406°F
D
Coast Guard Regulations
(46 CFR) regarding hydrostatic testing of main steam piping state that __________.
the hydrostatic
test pressure must be maintained on the piping for a minimum of one hour
a pipe with a
nominal size of six inches or more is not required to be hydrostatically
tested
not less than
fifty percent of the lagging shall be removed each time the hydrostatic
test is applied
the hydrostatic
test shall be applied from the boiler drum to the throttle valve
B
According to Coast
Guard Regulations (46 CFR), which of the following steam piping conditions,
subjected to main boiler pressure, is exempted from hydrostatic testing?
All piping to
the ship's service generators.
All piping with
a nominal size of 3 inches or less.
All piping from
the main steam stop to the throttle valve.
All piping equipped
with a safety or relief valve.
A
If the maximum
steam generating capacity of a boiler is increased Coast Guard Regulations
(46 CFR) require that the safety valve's __________.
relieving capacity
be checked
reseating pressure
be increased
blow down be reduced
lifting pressure
be increased
D
Coast Guard Regulations
(46 CFR) permit repairs and adjustments to boiler safety valves while installed
on a main propulsion boiler and may be made by __________.
any competent
person on the ship
only the safety
valve manufacturer
an approved repair
facility only
the chief engineer
in an emergency
C
Coast Guard Regulations,
46 CFR Part 54, require steam safety and relief valves to be provided with
a substantial lifting device, capable of lifting the disc from its seat
at what percentage of the set pressure?
0 (%)
25 (%)
75 (%)
90 (%)
B
Coast Guard Regulations
(46 CFR) require that the final setting of boiler safety valves be conducted
in presence of the __________.
COTP
marine inspector
chief engineer
OCMI
B
The MAWP of a
boiler is 900 psi and the normal drop across the superheater is 20 psi.
If the superheater safety valve is set to lift at 825 psi, the minimum settings
of the drum safety valves allowed by Coast Guard Regulations would be.
825 psi
850 psi
875 psi
900 psi
D
A boiler superheater
safety valve is set to lift at 450 psi ( kPa). Coast Guard Regulations
(46 CFR) require that if there is a pressure drop of 10 psi (69 kPa) across
the superheater, the drum safety valve should set to lift at a pressure
of __________.
450 psi (
kPa)
455 psi (
kPa)
460 psi (
kPa)
465 psi (
kPa)
D
The safety valve
nominal size for propulsion boilers and superheaters must be not less than
1 1/2 inches and not more than 4 inches. The term 'nominal size' refers
to the
free spring length
diameter of the
feather
diameter of the
huddling chamber
diameter of the
inlet opening
B
Coast Guard Regulations
(46 CFR) concerning superheater safety valves require that the valve.
is not set at
a pressure less than the feed pump relief valve
nominal size is
not less than 1.5 inches nor more than 4 inches
be set at a pressure
higher than the drum safety valves
can only be operated
by a pilot valve
B
Coast Guard Regulations
(46 CFR) concerning marine boilers, require the installation of a safety
valve on the __________.
preheated steam
outlet
superheated steam
outlet
desuperheated
steam outlet
auxiliary steam
outlet
B
Coast Guard regulations
require that the relieving capacity of boiler safety valves must be checked
__________.
when repairs have
been made to the safety valves
when the generating
capacity of the boiler is increased
at least once
every 4 years
at least once
a year
B
Coast Guard Regulations
(46 CFR) require the duplex fuel oil discharge strainers installed in boiler
fuel oil service systems to be __________.
enclosed in a
drip-proof vented enclosure to reduce the possibility of fire
located so as
to preclude the possibility of spraying oil on the burner or boiler casing
as close to the
fuel oil service manifold as practicable
a positive venting
system that will return any vapors to the pump suction
D
Coast Guard Regulations
(46 CFR Part 5 require that new fuel oil service piping between pumps and
burners be subjected to __________.
a hydrostatic
leak test to the design pressure specified by the Coast Guard
a hydrostatic
test of 1.25 times the maximum allowable pressure with the relief valves
closed
spot radiographic
examination of portions of the finished weld joints
a hydrostatic
test of 1.5 times the maximum allowable pressure but not less than 500 psi
( kPa)
A
Coast Guard Regulations
(46 CFR) require that quick-closing valves on a fuel oil service system
should be installed as close as is practicable to the __________.
boiler front fuel
oil header
fuel oil settling
tanks
fuel oil service
heaters
suction side of
the fuel oil pump
D
In accordance
with Coast Guard Regulations (46 CFR) all fuel oil service piping in the
vicinity of the burners must __________.
utilize leak proof
gaskets in all joints
have all joints
seal welded
be provided with
coamings or drip pans
have wrap around
deflectors on all bolted flanged joints
B
Coast Guard Regulations
(46 CFR) for boiler fuel oil service systems require __________.
all piping between
service pumps and burner fronts to be located below the floor plates to
eliminate fire hazards
machinery driving
fuel oil service pumps to be fitted with remote controls so that they may
be stopped in the event of a fire
fuel oil service
tanks to overhang boilers to utilize heat radiated from the boilers for
greater efficiency
fuel oil heaters
for boilers burning fuels with low viscosity
A
According to Coast
Guard Regulations (46 CFR), which of the following is permitted in boiler
fuel oil service system discharge piping?
Screwed bonnet
valves of the union bonnet type.
Pipe unions one
inch or greater in diameter.
Street ells made
of carbon steel.
Bushings made
of seamless steel.
B
Coast Guard Regulations
(46 CFR) require that the design pressure of an economizer integral with
the boiler and connected to the boiler drum without intervening stop valves
shall be at least equal to __________.
the feed pump
shut off head pressure
110% of the drum
safety valves highest set pressure
125% of the boiler
hydrostatic test pressure
150% of the boiler
design test pressure
C
When a boiler
economizer is fitted with a valved bypass, Coast Guard Regulations (46 CFR)
require which of the following devices to be installed?
A stop-check valve
is to be located at the economizer inlet.
An emergency drain
line must be provided to the reserve feed tank.
A stop-check valve
is to be located at the economizer outlet.
A sentinel valve
is to be fitted on the superheater outlet.
C
According to Coast
Guard Regulations (46 CFR), feed water nozzles shall be fitted with sleeves,
or have other suitable means employed to reduce the effects of temperature
differentials on all boilers designed for operating pressures of.
250 psig (
kPa) or over
300 psig (
kPa) or over
400 psig (
kPa) or over
600 psig (
kPa) or over
D
When preparing
to hydrostatically test water-tube boilers, you should __________.
remove all inspection
plates and manhole covers as required by the marine inspector
make arrangements
for simultaneously testing main and auxiliary steam stops with water and
steam pressure
have the boiler
warmed to a temperature not exceeding 100°F (37.8°C)
fill the boiler
with water not less than 70°F (21.1°C), nor more than 160°F (71.1°C)
B
Which of the following
statements is true concerning boiler inspections?
If the thickness
found as a result of gauging is less than original thickness, the boiler
must be condemned.
The marine inspector
may require any boiler to be drilled to determine its actual thickness any
time its safety is in doubt.
At the first inspection
for certification after a water-tube boiler has been installed for ten years,
it shall be gauged by drilling to determine the actual extent of deterioration.
Any user of a
nondestructive testing device must demonstrate that results with an accuracy
of plus or minus one percent are consistently obtainable.
C
According to 46
CFR Part 61, which of the following statements is true concerning the inspection
of water-tube boilers?
All boiler mounting
studs or bolts shall be removed for examination by a Coast Guard inspector
every 4 years after initial inspection.
o
Boiler mountings
attached to boiler nozzles must be opened and removed for examination every
8 years.
Boiler mountings
attached directly to the boiler plating by screwed studs and nuts shall
be removed and examined every 10 years.
All mountings
shall be opened up and examined by a Coast Guard inspector at eight year
intervals after the initial inspection.
B
Which of the following
statements represents the Coast Guard Regulation regarding a boiler installation
in which the superheater outlet temperature exceeds 850°F?
All mountings,
fittings, valves, or other superheater attachments must be of malleable
cast
iron.
Visible and audible
alarms indicating excessive superheat shall be provided.
Safety valves
are to be set at 110% of the highest setting of the safety valves on the
drum.
A device, actuated
by inlet static pressure and designed to function by the bursting of a pressure
retaining disk, must be fitted at the outlet of the superheater.
A
Which of the Coast
Guard publications listed contain the information regarding allowable repairs
to boilers installed on cargo vessels?
Marine Engineering
Regulations
Rules and Regulations
for Cargo and Miscellaneous Vessels
Manufacturer's
Instruction Manual
Modern Marine
Engineer's Manual
C
According to Coast
Guard Regulations (46 CFR), which of the following is classified as a boiler
mounting?
Escape piping
drain valve
Main feed check
valve
Blow off valve
Soot blower element
D
Coast Guard Regulations
(46 CFR) state that main propulsion water-tube boilers are not required
to be fitted with a surface blow off valve if the design pressure is __________.
300 psig (
kPa) or over
550 psig (
kPa) or over
500 psig (
kPa) or over
350 psig (
kPa) or over
C
Coast Guard Regulations
(46 CFR Part 56) permit copper pipe to be used for steam service subjected
to a maximum pressure and temperature of __________.
350 psi and 460°F
350 psi and 406°F
250 psi and 406°F
250 psi and 460°F
A
Coast Guard Regulations
(46 CFR) regarding hydrostatic testing of main steam piping state that __________.
the hydrostatic
test shall be applied from the boiler drum to the throttle valve
the hydrostatic
test pressure must be maintained on the piping for a minimum of one hour
not less than
fifty percent of the lagging shall be removed each time the hydrostatic
test is applied
a pipe with a
nominal size of six inches or more is not required to be hydrostatically
tested
B
According to Coast
Guard Regulations (46 CFR), which of the following steam piping conditions,
subjected to main boiler pressure, is exempted from hydrostatic testing?
All piping equipped
with a safety or relief valve.
All piping with
a nominal size of 3 inches or less.
All piping to
the ship's service generators.
All piping from
the main steam stop to the throttle valve.
C
If the maximum
steam generating capacity of a boiler is increased Coast Guard Regulations
(46 CFR) require that the safety valve's __________.
lifting pressure
be increased
blow down be reduced
relieving capacity
be checked
reseating pressure
be increased
A
Coast Guard Regulations
(46 CFR) permit repairs and adjustments to boiler safety valves while installed
on a main propulsion boiler and may be made by __________.
the chief engineer
in an emergency
any competent
person on the ship
only the safety
valve manufacturer
an approved repair
facility only
C
Coast Guard Regulations,
46 CFR Part 54, require steam safety and relief valves to be provided with
a substantial lifting device, capable of lifting the disc from its seat
at what percentage of the set pressure?
0 (%)
90 (%)
75 (%)
25 (%)
D
Coast Guard Regulations
(46 CFR) require that the final setting of boiler safety valves be conducted
in presence of the __________.
Chief Engineer
OCMI
COTP
Marine Inspector
C
The MAWP of a
boiler is 900 psi and the normal drop across the superheater is 20 psi.
If the superheater safety valve is set to lift at 825 psi, the minimum settings
of the drum safety valves allowed by Coast Guard Regulations would be __________.
875 psi
900 psi
850 psi
825 psi
C
A boiler superheater
safety valve is set to lift at 450 psi ( kPa). Coast Guard Regulations
(46 CFR) require that if there is a pressure drop of 10 psi (69 kPa) across
the superheater, the drum safety valve should set to lift at a pressure
of __________.
450 psi (
kPa)
455 psi (
kPa)
465 psi (
kPa)
460 psi (
kPa)
B
The safety valve
nominal size for propulsion boilers and superheaters must be not less than
1 1/2 inches and not more than 4 inches. The term 'nominal size' refers
to the __________.
free spring length
diameter of the
inlet opening
diameter of the
huddling chamber
diameter of the
feather
C
Coast Guard Regulations
(46 CFR) concerning superheater safety valves require that the valve __________.
is not set at
a pressure less than the feed pump relief valve
can only be operated
by a pilot valve
nominal size is
not less than 1.5 inches nor more than 4 inches
be set at a pressure
higher than the drum safety valves
A
Coast Guard Regulations
(46 CFR) concerning marine boilers, require the installation of a safety
valve on the __________.
superheated steam
outlet
desuperheated
steam outlet
preheated steam
outlet
auxiliary steam
outlet
D
Coast Guard regulations
require that the relieving capacity of boiler safety valves must be checked
__________.
at least once
every 4 years
at least once
a year
when repairs have
been made to the safety valves
when the generating
capacity of the boiler is increased
D
Coast Guard Regulations
(46 CFR) require the duplex fuel oil discharge strainers installed in boiler
fuel oil service systems to be __________.
as close to the
fuel oil service manifold as practicable
enclosed in a
drip-proof vented enclosure to reduce the possibility of fire
a positive venting
system that will return any vapors to the pump suction
located so as
to preclude the possibility of spraying oil on the burner or boiler casing
C
Coast Guard Regulations
(46 CFR Part 56) require that new fuel oil service piping between pumps
and burners be subjected to __________.
spot radiographic
examination of portions of the finished weld joints
o
a hydrostatic
leak test to the design pressure specified by the Coast Guard
a hydrostatic
test of 1.5 times the maximum allowable pressure but not less than 500 psi
( kPa)
a hydrostatic
test of 1.25 times the maximum allowable pressure with the relief valves
closed
B
Coast Guard Regulations
(46 CFR) require that quick-closing valves on a fuel oil service system
should be installed as close as is practicable to the __________.
fuel oil settling
tanks
boiler front fuel
oil header
suction side of
the fuel oil pump
fuel oil service
heaters
A
In accordance
with Coast Guard Regulations (46 CFR) all fuel oil service piping in the
vicinity of the burners must __________.
have wrap around
deflectors on all bolted flanged joints
have all joints
seal welded
utilize leak proof
gaskets in all joints
be provided with
coamings or drip pans
B
Coast Guard Regulations
(46 CFR) for boiler fuel oil service systems require __________.
fuel oil service
tanks to overhang boilers to utilize heat radiated from the boilers for
greater efficiency
machinery driving
fuel oil service pumps to be fitted with remote controls so that they may
be stopped in the event of a fire
fuel oil heaters
for boilers burning fuels with low viscosity
all piping between
service pumps and burner fronts to be located below the floor plates to
eliminate fire hazards
D
According to Coast
Guard Regulations (46 CFR), which of the following is permitted in boiler
fuel oil service system discharge piping?
Pipe unions one
inch or greater in diameter.
Street ells made
of carbon steel.
Bushings made
of seamless steel.
Screwed bonnet
valves of the union bonnet type.
B
All oil-fired
main propulsion burners with automatic safety control systems must automatically
close the burner valve when __________.
the burner is
properly seated
actuated by a
boiler safety trip
starting "trial
for ignition"
the flame in boiler
furnace is confirmed
C
Coast Guard Regulations
(46 CFR) require that the design pressure of an economizer integral with
the boiler and connected to the boiler drum without intervening stop valves
shall be at least equal to __________.
125% of the boiler
hydrostatic test pressure
150% of the boiler
design test pressure
110% of the drum
safety valves highest set pressure
the feed pump
shut off head pressure
A
When a boiler
economizer is fitted with a valved bypass, Coast Guard Regulations (46 CFR)
require which of the following devices to be installed?
A stop check valve
is to be located at the economizer outlet.
A sentinel valve
is to be fitted on the superheater outlet.
A stop check valve
is to be located at the economizer inlet.
An emergency drain
line must be provided to the reserve feed tank.
A
According to Coast
Guard Regulations (46 CFR), feed water nozzles shall be fitted with sleeves,
or have other suitable means employed to reduce the effects of temperature
differentials on all boilers designed for operating pressures of __________.
400 psig (
kPa) or over
250 psig (
kPa) or over
600 psig (
kPa) or over
300 psig (
kPa) or over
C
If a quantity
of saturated steam consists of 90 percent steam and 10 percent moisture,
the quality of the mixture is __________.
10 (%)
80 (%)
90 (%)
100 (%)
D
If a boiler generates
saturated steam at 125.3 psig, how much heat is required to change the water
into steam if the feed water temperature is 240°F? Illustration SG-
30.5 Btu/lb
116.5 Btu/lb
582.7 Btu/lb
983.4 Btu/lb
C
The best conductor
of heat in a marine boiler is __________.
water
brick
steel
steam
C
At a given pressure,
erosion of steam piping and machinery will be minimized by utilizing __________.
saturated steam
desuperheated
vapor
superheated steam
wet steam
C
Which type of
energy conversion is associated with an operating steam boiler?
Mechanical
Specific
Thermal
Kinetic
C
Most marine boilers
are designed to produce __________.
saturated steam
only
superheated steam
only
saturated and
superheated steam
superheated and
supercritical steam
C
Which of the following
statements describes the effects that dissolved oxygen has on boiler internal
surfaces with changes in temperature and pressure?
It increases the
corrosive effect with lowered pressure and increases its corrosive effect
with increased temperature.
It decreases the
corrosive effect when both pressure and temperature are increased.
It increases the
corrosive effect with increased pressure and decreases its corrosive effect
with increased temperature.
Temperature and
pressure have no effect on the corrosive effect of dissolved oxygen.
A
Which of the stated
pressure conditions identifies the boiler design pressure?
The pressure specified
by the manufacturer as a criterion for boiler design.
The pressure at
which a boiler is operated during overload conditions.
The same pressure
as the boiler operating pressure at full power capacity.
A pressure lower
than boiler operating pressure.
B
Which of the following
conditions must exist before the superheating of saturated steam can occur
in a steam propulsion boiler?
The firing rate
of the boiler must be increased.
The steam must
be directed to an area separate from the steam drum.
The flow of feed
water to the boiler must be increased.
The economizer
must be on line.
B
The greatest deterrent
to heat transfer from the fireside to the waterside of a boiler is __________.
water film
gas film
water eddies
gas eddies
C
With an increase
in the saturation pressure of a fluid, the value represented by line "5"
on the graph will __________. Illustration SG-
increase the number
of BTU's per pound, per change in degree of temperature
decrease the number
of BTU's per pound, per change in degree of temperature
remain virtually
the same
represent an increase
in the latent heat of condensation
C
With reference
to the chart, if a boiler generates saturated steam at 385.3 psig, how much
heat per pound was required to change the water into steam if the feed water
temperature was initially 104.5°C? Illustration SG-
96.85 BTU
97.15 BTU
.40 BTU
.45 BTU
C
According to the
data given in illustration, which of the following would be the physical
state of the fluid at a gage vacuum of 28.09 inches Hg, and 117.99 degrees
Fahrenheit? Illustration SG-
Sub cooled liquid.
Saturated liquid.
Superheated vapor.
Mixture of saturated
liquid and vapor.
C
According to the
data given in the illustration, which of the following would be the physical
state of the fluid at a gage vacuum of 29.00 inches Hg, and 85.21 degrees
Fahrenheit? Illustration SG-
Sub cooled liquid.
Saturated liquid.
Superheated vapor.
Mixture of saturated
liquid and vapor.
D
Assume that steam
has formed in a boiler in which all of the steam stop valves are closed,
and the water level is held constant. When there is an increase in the temperature
of the steam and water in the boiler, which of the following effects will
occur on the pressure and the specific volume of the steam?
The steam pressure
and volume will remain constant.
The pressure will
increase and the volume will remain constant.
The pressure will
remain constant and the volume will increase.
The pressure will
increase and the specific volume will decrease.
A
Steam tables can
be used to obtain the __________.
values for properties
of water and steam vapor at various conditions
mechanical efficiency
of the main unit
steam generating
capacity of a vessel's boilers
specific fuel
consumption under steady steaming conditions
C
From which of
the areas listed are condensate drains normally collected and returned to
the low-pressure drain system?
Steam systems
operating in excess of 150 psi
Steam whistle
separator/trap
Main and auxiliary
air ejector after condensers
Each main feed
pump steam supply line
C
A basic comparison
can be made between a low pressure evaporator operation and a main condenser
with regards to the removal of non-condensable gases. The vacuum drag line
for the main condenser is specifically connected in which area?
hot well
steam lane
air cooler section
main tube bank
A
Which of the listed
systems would be a potential source for the high pressure drain system?
Steam systems
operating in excess of 150 psi
Galley steam tables
Laundry steam
pressing machines
Fuel oil tank
heating coils
What Are the Key Benefits of 0.5 Ton Steam Boilers?
Understanding the 0.5 Ton Steam Boiler and Its Applications
When considering steam boilers for various industrial applications, one often comes across the 0.5 Ton Steam Boiler. This compact and efficient solution has become increasingly popular among businesses for its unique advantages. Whether you're in manufacturing, food processing, or other sectors, understanding the benefits of a 0.5 Ton Steam Boiler can help you make an informed decision.
For more information, please visit Partedon Group.
If you are looking for more details, kindly visit 0.5 Ton Steam Boiler(hi,in,vi).
Compact and Efficient Design
One of the primary benefits of a 0.5 Ton Steam Boiler is its compact design. These boilers are specifically engineered to fit into limited spaces without compromising on performance. Their small footprint makes them ideal for facilities that may not have excessive room for larger heating systems.
Moreover, their efficiency enhances performance, allowing businesses to produce steam quickly and economically. For instance, in a small manufacturing unit, a 0.5 Ton Steam Boiler can provide sufficient steam for processes like sterilization or cooking without requiring additional space or resources.
Cost-Effective Operation
Business owners are always looking for ways to reduce operating costs, and a 0.5 Ton Steam Boiler can be a game-changer in this regard. These boilers consume less fuel compared to larger models, translating to lower energy costs—a crucial consideration in today’s eco-conscious market.
Additionally, because of their smaller size, maintenance costs tend to be lower. Routine inspections and repairs are generally less time-consuming and less intensive, which can save both time and money for business operations.
Versatility in Use
Another significant advantage of a 0.5 Ton Steam Boiler is its versatility. These boilers can be utilized in a variety of applications including heating, drying, cleaning, and generating power. This makes them suitable for several industries, such as:
- Food Processing: Steam is essential for cooking and cleaning processes in food manufacturing.
- Textile Industry: Boilers are used for dyeing and fabric finishing.
- Pharmaceuticals: Steam is vital in the sterilization processes.
Because of this versatility, investing in a 0.5 Ton Steam Boiler can provide long-term benefits and adaptability to changing business needs.
Contact us to discuss your requirements of 0.5 Ton Gas Steam Generator. Our experienced sales team can help you identify the options that best suit your needs.
If you want to learn more, please visit our website Steam Boiler.
Environmental Benefits
In an age increasingly focused on sustainability, the 0.5 Ton Steam Boiler stands out for its lower emissions. Many modern designs are equipped with advanced combustion technologies that reduce greenhouse gases and pollutants. This not only helps businesses comply with environmental regulations but also enhances their corporate responsibility image.
For businesses aiming to reduce their carbon footprint, choosing a 0.5 Ton Steam Boiler can be a step in the right direction. Moreover, using less fuel also means conserving natural resources, which is a win-win for both the business and the planet.
Common Questions About the 0.5 Ton Steam Boiler
What industries commonly use a 0.5 Ton Steam Boiler?
As mentioned, industries such as food processing, textiles, and pharmaceuticals frequently utilize 0.5 Ton Steam Boilers due to their diverse applications and efficiency.
How much steam can a 0.5 Ton Steam Boiler produce?
A 0.5 Ton Steam Boiler can produce roughly 500 kg of steam per hour. This capacity is typically adequate for smaller manufacturers and can be scaled up with multiple units if needed.
Are there specific maintenance requirements for these boilers?
Yes, while 0.5 Ton Steam Boilers are easier to maintain, regular checks on safety valves, water levels, and system pressure are still essential. Scheduled servicing by certified professionals can help keep your boiler in top shape and extend its life.
Where can I find a reliable supplier of 0.5 Ton Steam Boilers?
It's recommended to do thorough research and read customer reviews before selecting a supplier. Look for companies that offer warranties and have a good reputation in the industry for customer service and technical support.
Conclusion
The 0.5 Ton Steam Boiler stands out as an optimal choice for many businesses seeking a compact, cost-effective, and versatile steam generating solution. Its numerous benefits, ranging from increased efficiency to environmental advantages, make it an essential element of modern industrial practices. By considering your specific needs and consulting with experts, you can effectively leverage the significant advantages offered by a 0.5 Ton Steam Boiler in your operations.
For more information, please visit 1.2 Ton Gas Steam Generator.